1.Shexiang Tongxin Dropping Pill Improves Stable Angina Patients with Phlegm-Heat and Blood-Stasis Syndrome: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial.
Ying-Qiang ZHAO ; Yong-Fa XING ; Ke-Yong ZOU ; Wei-Dong JIANG ; Ting-Hai DU ; Bo CHEN ; Bao-Ping YANG ; Bai-Ming QU ; Li-Yue WANG ; Gui-Hong GONG ; Yan-Ling SUN ; Li-Qi WANG ; Gao-Feng ZHOU ; Yu-Gang DONG ; Min CHEN ; Xue-Juan ZHANG ; Tian-Lun YANG ; Min-Zhou ZHANG ; Ming-Jun ZHAO ; Yue DENG ; Chang-Jiang XIAO ; Lin WANG ; Bao-He WANG
Chinese journal of integrative medicine 2025;31(8):685-693
OBJECTIVE:
To evaluate the efficacy and safety of Shexiang Tongxin Dropping Pill (STDP) in treating stable angina patients with phlegm-heat and blood-stasis syndrome by exercise duration and metabolic equivalents.
METHODS:
This multicenter, randomized, double-blind, placebo-controlled clinical trial enrolled stable angina patients with phlegm-heat and blood-stasis syndrome from 22 hospitals. They were randomized 1:1 to STDP (35 mg/pill, 6 pills per day) or placebo for 56 days. The primary outcome was the exercise duration and metabolic equivalents (METs) assessed by the standard Bruce exercise treadmill test after 56 days of treatment. The secondary outcomes included the total angina symptom score, Chinese medicine (CM) symptom scores, Seattle Angina Questionnaire (SAQ) scores, changes in ST-T on electrocardiogram and adverse events (AEs).
RESULTS:
This trial enrolled 309 patients, including 155 and 154 in the STDP and placebo groups, respectively. STDP significantly prolonged exercise duration with an increase of 51.0 s, compared to a decrease of 12.0 s with placebo (change rate: -11.1% vs. 3.2%, P<0.01). The increase in METs was significantly greater in the STDP group than in the placebo group (change: -0.4 vs. 0.0, change rate: -5.0% vs. 0.0%, P<0.01). The improvement of total angina symptom scores (25.0% vs. 0.0%), CM symptom scores (38.7% vs. 11.8%), reduction of nitroglycerin consumption (100.0% vs. 11.3%), and all domains of SAQ, were significantly greater with STDP than placebo (all P<0.01). The changes in Q-T intervals at 28 and 56 days from baseline were similar between the two groups (both P>0.05). Twenty-five participants (16.3%) with STDP and 16 (10.5%) with placebo experienced AEs (P=0.131), with no serious AEs observed.
CONCLUSION
STDP could improve exercise tolerance in patients with stable angina and phlegm-heat and blood stasis syndrome, with a favorable safety profile. (Registration No. ChiCTR-IPR-15006020).
Humans
;
Double-Blind Method
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Middle Aged
;
Angina, Stable/physiopathology*
;
Aged
;
Syndrome
;
Treatment Outcome
;
Placebos
;
Tablets
2.Advances in therapeutic drug monitoring methods based on liquid chromatography-tandem mass spectrometry
Ziying LI ; Jie XIE ; Ziyu QU ; You JIANG ; Di ZHANG ; Songlin YU ; Xiaoli MA ; Ling QIU ; Xinhua DAI ; Xiang FANG ; Xiaoping YU
Chinese Journal of Laboratory Medicine 2024;47(3):332-340
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology has the characteristics of high specificity and high throughput, making it rapidly applied and developed in the field of clinical testing. Its application in the monitoring of therapeutic drugs can effectively improve the quantitative accuracy and sensitivity, and formulate a personalized and optimal dosing plan for patients. However, this technology still faces some challenges, and automation, quality control, and quantitative traceability will be the future development direction.
3.Molecular biological mechanism of acquired heterotopic ossification
Yang XIONG ; Shibo ZHOU ; Xing YU ; Lianyong BI ; Jizhou YANG ; Fengxian WANG ; Yi QU ; Yongdong YANG ; Dingyan ZHAO ; He ZHAO ; Ziye QIU ; Guozheng JIANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4881-4888
BACKGROUND:Heterotopic ossification is a dynamic growth process.Diverse heterotopic ossification subtypes have diverse etiologies or induction factors,but they exhibit a similar clinical process in the intermediate and later phases of the disease.Acquired heterotopic ossification produced by trauma and other circumstances has a high incidence. OBJECTIVE:To summarize the molecular biological mechanisms linked to the occurrence and progression of acquired heterotopic ossification in recent years. METHODS:The keywords"molecular biology,heterotopic ossification,mechanisms"were searched in CNKI,Wanfang,PubMed,Embase,Web of Science,and Google Scholar databases for articles published from January 2016 to August 2022.Supplementary searches were conducted based on the obtained articles.After the collected literature was screened,131 articles were finally included and summarized. RESULTS AND CONCLUSION:(1)The occurrence and development of acquired heterotopic ossification is a dynamic process with certain concealment,making diagnosis and treatment of the disease difficult.(2)By reviewing relevant literature,it was found that acquired heterotopic ossification involves signaling pathways such as bone morphogenetic protein,transforming growth factor-β,Hedgehog,Wnt,and mTOR,as well as core factors such as Runx-2,vascular endothelial growth factor,hypoxia-inducing factor,fibroblast growth factor,and Sox9.The core mechanism may be the interaction between different signaling pathways,affecting the body's osteoblast precursor cells,osteoblast microenvironment,and related cytokines,thereby affecting the body's bone metabolism and leading to the occurrence of acquired heterotopic ossification.(3)In the future,it is possible to take the heterotopic ossification-related single-cell osteogenic homeostasis as the research direction,take the osteoblast precursor cells-osteogenic microenvironment-signaling pathways and cytokines as the research elements,explore the characteristics of each element under different temporal and spatial conditions,compare the similarities and differences of the osteogenic homeostasis of different types and individuals,observe the regulatory mechanism of the molecular signaling network of heterotopic ossification from a holistic perspective.It is beneficial to the exploration of new methods for the future clinical prevention and treatment of heterotopic ossification.(4)Meanwhile,the treatment methods represented by traditional Chinese medicine and targeted therapy have become research hotspots in recent years.How to link traditional Chinese medicine with the osteogenic homeostasis in the body and combine it with targeted therapy is also one of the future research directions.(5)At present,the research on acquired heterotopic ossification is still limited to basic experimental research and the clinical prevention and treatment methods still have defects such as uncertain efficacy and obvious side effects.The safety and effectiveness of relevant targeted prevention and treatment drugs in clinical application still need to be verified.Future research should focus on clinical prevention and treatment based on basic experimental research combined with the mechanism of occurrence and development.
4.Digital PCR Chip for Multiple Quantitative Detection of Foodborne Bacteria
Zhen-Zhen MAO ; Wen-Qi HU ; Qu TANG ; Wen-Jun JIANG ; Yu-Ling QIN ; Li WU
Chinese Journal of Analytical Chemistry 2024;52(6):789-798
The presence of food-borne pathogenic bacteria poses a severe threat to human health. Therefore,it is essential to develop effective methods for bacteria detection. Herein,a method based on digital polymerase chain reaction (PCR) chip was developed for rapid and effective detection of three kinds of common food-borne bacteria (Staphylococcus aureus,Salmonella typhimurium and Listeria monocytogenes). Driven by centrifugal force,samples could be easily loaded and digitized in 15 min. PCR results showed that the positive microchambers in the chip could be identified after 25 thermal cycles. The chip had advantages in the quantitative detection of bacterial nucleic acid at low concentration,which could effectively avoid false negative results. Multiple detection of bacterial samples with concentration of 105-108 CFU/mL could also be realized using this chip. Compared with fluorescent quantitative PCR,this method had higher accuracy and sensitivity,especially for detection of targets at low concentration.
5.Clinical phenotypes and genotypes of congenital fibrinogen disorder:an analysis of 16 children
Min WANG ; Tian-Ping CHEN ; Ao-Shuang JIANG ; Ying-Hui ZHAO ; Cheng-Lin ZHU ; Nan WEI ; Yu-Ting JIN ; Li-Jun QU
Chinese Journal of Contemporary Pediatrics 2024;26(8):840-844
Objective To investigate the clinical phenotypes and genotypes of children with congenital fibrinogen disorder(CFD).Methods A retrospective analysis was conducted on the clinical data of 16 children with CFD.Polymerase chain reaction was used to amplify all exons and flanking sequences of the FGA,FGB,and FGG genes,and sequencing was performed to analyze mutation characteristics.Results Among the 16 children,there were 9 boys(56%)and 7 girls(44%),with a median age of 4 years at the time of attending the hospital.Among these children,9(56%)attended the hospital due to bleeding events,and 7(44%)were diagnosed based on preoperative examination.The children with bleeding events had a significantly lower fibrinogen activity than those without bleeding events(P<0.05).Genetic testing was conducted on 12 children and revealed a total of 12 mutations,among which there were 4 novel mutations,i.e.,c.80T>C and c.1368delC in the FGA gene and c.1007T>A and C.1053C>A in the FGG gene.There were 2 cases of congenital afibrinogenemia caused by null mutations of the FGA gene,with relatively severe bleeding symptoms.There were 7 cases of congenital dysfibrinogenemia mainly caused by heterozygous missense mutations of the FGG and FGA genes,and their clinical phenotypes ranged from asymptomatic phenotype to varying degrees of bleeding.Conclusions The clinical phenotypes of children with CFD are heterogeneous,and the severity of bleeding is associated with the level of fibrinogen activity,but there is a weak association between clinical phenotype and genotype.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
9.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
10.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.

Result Analysis
Print
Save
E-mail