1.Transit Time Flowmetry and Vein Size Are Predictive of Arteriovenous Fistula Maturation
Yelee KWON ; YoungJong CHO ; Pil Je KANG ; Won Chul CHO
The Korean Journal of Thoracic and Cardiovascular Surgery 2020;53(5):297-300
Background:
This study aimed to assess the effect of vessel size and flow characteristics on the maturation of autogenous radiocephalic arteriovenous fistulae (RCAVFs).
Methods:
We retrospectively reviewed records of patients undergoing RCAVF creation at a single medical center from January 2013 to December 2019. Operative variables were compared between patients whose fistulae matured and those whose fistulae failed to mature.
Results:
Overall, 152 patients (33 of whom were women) with a mean age of 62.6±13.6 years underwent RCAVF creation; functional maturation was achieved in 123. No statistically significant differences were observed between patients in whom maturation was or was not achieved in terms of the following variables: female sex (20.3% vs. 25.0%), radial artery size (2.5 vs. 2.4 mm), and pulsatility index (0.69 vs. 0.62). Low intraoperative transit time flowmetry (TTF; 150.4 vs. 98.1 mL/min) and small vein size (2.4 vs. 2.0 mm) were associated with failure of maturation. The best cutoff diameter for RCAVF TTF and cephalic vein size were 105 mL/min and 2.45 mm, respectively.
Conclusion
In patients who undergo RCAVF creation, vein diameter on preoperative ultrasonography and intraoperative TTF are predictors of functional maturation. We identified an intraoperative TTF cutoff value that can be used for intraoperative decision-making.
2.Uterine Artery Embolization as an Effective Management and Diagnostic Tool for Puerperal Uterine Inversion with Severe Postpartum Bleeding: A Case Report
Seong Ju KIM ; Youngjong CHO ; Sung-Joon PARK ; Sangjoon LEE ; Hyoung Nam LEE ; Da Hye JU
Journal of the Korean Radiological Society 2022;83(3):699-704
Acute puerperal uterine inversion is a rare postpartum obstetric complication; however, without rapid diagnosis and appropriate management, it is life-threatening. Substantial bleeding hinders the verification of a partially inverted uterus, possibly delaying the treatment. Herein, we present the report of a 32-year-old female presenting with massive postpartum bleeding managed by uterine artery embolization. The peculiar course of the uterine artery bowing inferiorly along the inverted fundus during embolization could uncover the uterine inversion, which was not diagnosed by physical examination and CT. In conclusion, uterine artery embolization is not only an effective therapeutic strategy for postpartum hemorrhage but also a valuable tool for diagnosing uterine inversion.
3.Performance Evaluation of Elecsys Vitamin D Total II Assay Using Roche Modular Analytics E170.
Eun Jung CHO ; Hyunjung KIM ; Jeongho PARK ; Dongsik KIM ; Youngjong CHA ; Hae Kyung LEE
Journal of Laboratory Medicine and Quality Assurance 2018;40(2):109-111
We evaluated the performance of a recently developed immunoassay, Elecsys vitamin D total II assay (Roche Diagnostics GmbH, Germany). Precision, linearity, and comparison studies were performed according to the Clinical and Laboratory Standards Institute guidelines. Control materials, linearity materials, and patient samples were used for the evaluation. For the correlation study, liquid chromatography-tandem mass spectrometry was used as the comparative method. Total coefficients of variations of the analyte were between 5.1% and 9.6%. The results of linearity evaluation were also acceptable for the range tested. Correlations with comparative methods were good; however, the mean values of the Elecsys vitamin D assay were higher than those of liquid chromatography-tandem mass spectrometry. The overall analytical performance of the Elecsys vitamin D total II assay is acceptable for the immunology analyzer. Therefore, the Elecsys vitamin D total II assay is expected to be widely used.
Allergy and Immunology
;
Humans
;
Immunoassay
;
Mass Spectrometry
;
Methods
;
Statistics as Topic
;
Vitamin D*
;
Vitamins*