1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
4.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Identification of acute myocardial infarction and stroke events using the National Health Insurance Service database in Korea
Minsung CHO ; Hyeok-Hee LEE ; Jang-Hyun BAEK ; Kyu Sun YUM ; Min KIM ; Jang-Whan BAE ; Seung-Jun LEE ; Byeong-Keuk KIM ; Young Ah KIM ; JiHyun YANG ; Dong Wook KIM ; Young Dae KIM ; Haeyong PAK ; Kyung Won KIM ; Sohee PARK ; Seng Chan YOU ; Hokyou LEE ; Hyeon Chang KIM
Epidemiology and Health 2024;46(1):e2024001-
OBJECTIVES:
The escalating burden of cardiovascular disease (CVD) is a critical public health issue worldwide. CVD, especially acute myocardial infarction (AMI) and stroke, is the leading contributor to morbidity and mortality in Korea. We aimed to develop algorithms for identifying AMI and stroke events from the National Health Insurance Service (NHIS) database and validate these algorithms through medical record review.
METHODS:
We first established a concept and definition of “hospitalization episode,” taking into account the unique features of health claims-based NHIS database. We then developed first and recurrent event identification algorithms, separately for AMI and stroke, to determine whether each hospitalization episode represents a true incident case of AMI or stroke. Finally, we assessed our algorithms’ accuracy by calculating their positive predictive values (PPVs) based on medical records of algorithm- identified events.
RESULTS:
We developed identification algorithms for both AMI and stroke. To validate them, we conducted retrospective review of medical records for 3,140 algorithm-identified events (1,399 AMI and 1,741 stroke events) across 24 hospitals throughout Korea. The overall PPVs for the first and recurrent AMI events were around 92% and 78%, respectively, while those for the first and recurrent stroke events were around 88% and 81%, respectively.
CONCLUSIONS
We successfully developed algorithms for identifying AMI and stroke events. The algorithms demonstrated high accuracy, with PPVs of approximately 90% for first events and 80% for recurrent events. These findings indicate that our algorithms hold promise as an instrumental tool for the consistent and reliable production of national CVD statistics in Korea.
9.Effectiveness of Live-Streaming Tele-Exercise Intervention in Patients With Parkinson’s Disease: A Pilot Study
Jongmok HA ; Jung Hyun PARK ; Jun Seok LEE ; Hye Young KIM ; Ji One SONG ; Jiwon YOO ; Jong Hyeon AHN ; Jinyoung YOUN ; Jin Whan CHO
Journal of Movement Disorders 2024;17(2):189-197
Objective:
Exercise can improve both motor and nonmotor symptoms in people with Parkinson’s disease (PwP), but there is an unmet need for accessible and sustainable exercise options. This study aimed to evaluate the effect, feasibility, and safety of a regularly performed live-streaming tele-exercise intervention for PwP.
Methods:
A live-streaming exercise intervention for PwP was implemented twice a week for 12 weeks. We measured the motor and nonmotor symptom scores of the included patients before and after the intervention. Changes in clinical scores from baseline to postintervention were analyzed using paired t-tests. Factors associated with improvements in clinical scores and compliance were analyzed using Pearson’s correlation analysis.
Results:
Fifty-six participants were enrolled in the study. There were significant improvements in Hospital Anxiety and Depression Scale (HADS)-anxiety (p = 0.007), HADS-depression (p < 0.001), Unified Parkinson’s Disease Rating Scale (UPDRS) part III (p < 0.001), UPDRS total (p = 0.015), Hoehn and Yahr stage (p = 0.027), and Parkinson’s Disease Fatigue Scale-16 (p = 0.026) scores after the intervention. Improvements in motor symptoms were associated with improvements in mood symptoms and fatigue. Higher motor impairment at baseline was associated with a greater compliance rate and better postintervention composite motor and nonmotor outcomes (ΔUPDRS total score). Overall, the 12-week tele-exercise program was feasible and safe for PwP. No adverse events were reported. The overall adherence rate was 60.0% in our cohort, and 83.4% of the participants were able to participate in more than half of the exercise routines.
Conclusion
The live-streaming tele-exercise intervention is a safe, feasible, and effective nonpharmacological treatment option that can alleviate fatigue and improve mood and motor symptoms in PwP.
10.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.

Result Analysis
Print
Save
E-mail