1.Utility of ABO Genotyping by Integrating the ABO Gene into Diagnostic Gene Panels for Patients with Hematologic Malignancies
Yun Mi PARK ; Gye Cheol KWON ; Seon Young KIM
Annals of Laboratory Medicine 2025;45(5):539-544
Serologic ABO typing might be hampered in some patients with hematologic malignancies.We performed ABO genotyping using next-generation sequencing as part of a routine hematologic malignancy gene panel to determine the ABO blood type of patients with hematologic malignancies. Targeted sequencing of seven ABO gene exons was performed within a hematologic malignancy gene panel for 520 patients diagnosed with various hematologic malignancies. The distribution of predicted ABO blood phenotypes determined through genotyping was as follows: 33.3% A, 27.3% B, 26.7% O, and 12.7% AB. No significant associations were identified between ABO allele distributions and specific hematologic malignancy diagnoses. We compared the phenotypes predicted using ABO genotyping with serological ABO testing results in 502 samples where serological data were available. All genotyping-based phenotypes were accurate, with 99.8% (501/502) of initial serological results aligning with the true phenotypes. Unusual serological results were observed in 21 samples (4.2%). The percentages of recipient cells containing ABO allele variants indicated chimerism in relapsed patients who had undergone ABO-mismatched transplantation. Thus, incorporating ABO genotyping into the hematology gene panel provides valuable information offering a cost-effective approach to address challenges in blood typing and post-transplant care.
2.3D Facial Scanners: How to Make the Right Choice for Orthodontists
Young-Soo SEO ; Do-Gil KIM ; Gye-Hyeong LEE ; Kyungmin Clara LEE
Journal of Korean Dental Science 2024;17(1):1-13
With the advances of digital scanning technology in dentistry, the interests in facial scanning in orthodontics have increased.There are many different manufacturers of facial scanners marketing to the dental practice. How do you know which one will work best for you? What questions should you be asking? We suggest a clinical guideline which may help you make an informed decision when choosing facial scanners. The characteristics of 7 facial scanners were discussed in this article. Here are some considerations for choosing a facial scanner. *Accuracy: For facial scanners to be of real value, having an appropriate camera resolution is necessary to achieve more accurate facial image representation. For orthodontic application, the scanner must create an accurate representation of an entire face. *Ease of Use: Scanner-related issues that impact their ease of use include type of light; scan type; scan time; file type generated by the scanner; unit size and foot print; and acceptance of scans by third-party providers. *Cost: Most of the expenses associated with facial scanning involve the fixed cost of purchase and maintenance. Other expenses include technical support, warranty costs, transmission fees, and supply costs. This article suggests a clinical guideline to make the right choice for facial scanner in orthodontics.
3.Anterior Displacement of the Eyeball in a Patient with Uncontrolled Schizophrenia
Si Young KIM ; Yeong A CHOI ; Gye Jung KIM
Journal of the Korean Ophthalmological Society 2024;65(8):540-544
Purpose:
To report a case in which vision improvement was achieved following surgery for anterior displacement of the eyeball resulting from self-mutilation in a patient with schizophrenia.Case summary: A 37-year-old female patient with schizophrenia was admitted following an attempt at self-mutilation, which led to anterior displacement of her right eyeball. Initial evaluation revealed that reduction was not feasible and visual acuity was finger count at 20 cm in the right eye. Orbital computed tomography indicated 26-mm anterior displacement of the eyeball from the center of the cornea to the interzygomatic line along with a small retrobulbar hemorrhage and edema in the superior rectus muscle. Surgical intervention, consisting of lateral canthotomy, cantholysis, and tarsorrhaphy, was performed for correction. The surgical site was reconstructed 6 days after surgery. A fundus examination conducted 1 month later revealed no abnormalities and best-corrected visual acuity improved to 20/20.
Conclusions
Globe subluxation due to self-mutilation is a very rare and urgent condition in both ophthalmic and psychiatric contexts that requires immediate surgical intervention. This case demonstrates that immediate anatomical reduction when there is no direct suspicion of optic nerve damage can be beneficial for the recovery of visual acuity and may lead to a favorable prognosis.
4.Self-Reported Findings of the Korean Intermittent Exotropia Multicenter Study Questionnaire
Hee Kyung YANG ; Shin Hae PARK ; Haeng-Jin LEE ; Sook-Young KIM ; Hyo Jung GYE ; So Young KIM ; Sun Young SHIN ; Key Hwan LIM ;
Korean Journal of Ophthalmology 2024;38(3):194-202
Purpose:
To determine subjective symptoms and medical history of patients with intermittent exotropia in a large study population.
Methods:
The Korean Intermittent Exotropia Multicenter Study (KIEMS) is a nationwide, observational, cross-sectional, multicenter study conducted by the Korean Association for Pediatric Ophthalmology and Strabismus including 5,385 patients with intermittent exotropia. Subjective symptoms and medical history of patients with intermittent exotropia were extracted by a comprehensive survey based on a self-administered questionnaire according to the study protocol of the KIEMS.
Results:
The mean age of symptom onset was 5.5 years. The most common symptom reported in patients with intermittent exotropia was photophobia (52.1%), followed by diplopia at near fixation (7.3%) and distance fixation (6.2%). Preterm birth was found in 8.8%, and 4.1% had perinatal complications. A family history of strabismus was present in 14.9%, and 5.5% of patients had a family member who underwent strabismus surgery.
Conclusions
The KIEMS is one of the largest clinical studies on intermittent exotropia. Intermittent exotropia frequently caused photophobia and diplopia, and patients with a family history was not uncommon.
5.Regulation of Phosphorylation of Glycogen Synthase Kinase 3α and the Correlation with Sperm Motility in Human
Seung Hyun PARK ; Young-Pil KIM ; Jeong Min LEE ; Dong-Wook PARK ; Ju Tae SEO ; Myung Chan GYE
The World Journal of Men's Health 2024;42(2):373-383
Purpose:
To unravel the mechanism regulating the phosphorylation of glycogen synthase kinase 3 (GSK3) and the correlation between the inhibitory phosphorylation of GSK3α and sperm motility in human.
Materials and Methods:
The phosphorylation and priming phosphorylated substrate-specific kinase activity of GSK3 were examined in human spermatozoa with various motility conditions.
Results:
In human spermatozoa, GSK3α/β was localized in the head, midpiece, and principal piece of tail and p-GSK3α(Ser21) was enriched in the midpiece. The ratio of p-GSK3α(Ser21)/GSK3α was positively coupled with normal sperm motility criteria of World Health Organization. In high-motility spermatozoa, p-GSK3α(Ser21) phosphotyrosine (p-Tyr) proteins but p-GSK3α(Tyr279) markedly increased together with decreased kinase activity of GSK3 after incubation in Ca2+ containing medium. In high-motility spermatozoa, p-GSK3α(Ser21) levels were negatively coupled with kinase activity of GSK3, and which was deregulated in low-motility spermatozoa. In high-motility spermatozoa, 6-bromo-indirubin-3′-oxime, an inhibitor of kinase activity of GSK3 increased p-GSK3α(Ser21) and p-Tyr proteins. p-GSK3α(Ser21) and p-Tyr protein levels were decreased by inhibition of PKA and Akt. Calyculin A, a protein phosphatase-1/2A inhibitor, markedly increased the p-GSK3α(Ser21) and p-Tyr proteins, and significantly increased the motility of low-motility human spermatozoa.
Conclusions
Down regulation of kinase activity of GSK3α by inhibitory phosphorylation was positively coupled with human sperm motility, and which was regulated by Ca2+, PKA, Akt, and PP1. Small-molecule inhibitors of GSK3 and PP1 can be considered to potentiate human sperm motility.
6.Testicular granular cell tumor of two rabbits: case reports
Na-Young LEE ; Jeong Seong LEE ; Byung Hoon YU ; Jae-Hoon KIM ; Dae-Yong KIM ; Gye-Hyeong WOO
Korean Journal of Veterinary Research 2023;63(4):e32-
Granular cell tumor was described in the testis of two rabbits. Testis from each rabbit was surgically removed and submitted for histopathological diagnosis. Both testes were about 2.0 cm in diameter, firm, and tan. Microscopically, testicular mass consisted of compact sheets of round to polygonal and occasional spindle-shaped cells. The neoplastic cells contain a large amount of eosinophilic granular material in the cytoplasm. The cytoplasmic eosinophilic granules were positive for periodic acid Schiff stain. Immunohistochemically, the neoplastic cells were immunoreactive to Melan-A and vimentin. Based on these results, the testicular mass was diagnosed as a granular cell tumor.
7.Capacitive coupling leading to electrical skin burn injury during laparoscopic surgery
Woo Jun KIM ; Gyung Mo SON ; In Young LEE ; Sung Uk YUN ; Gye Rok JEON ; Dong-Hoon SHIN ; Myung Sook KWON ; Jae Yeong KWAK ; Kwang-Ryul BAEK
Journal of Minimally Invasive Surgery 2022;25(3):106-111
Purpose:
Trocar-site burns occurring during laparoscopic surgery have been reported in various cases, and several efforts to reduce them are underway. This study aimed to analyze the effect of capacitive coupling on trocar site by observing electrical and histological changes for electrical skin burn injury.
Methods:
To measure the electrical changes relating to capacitive coupling, the temperature, current, voltage, and impedance around the trocar were measured when an open circuit and a closed circuit were formed using insulation intact instruments and repeated after insulation failure. After the experiment, the tissue around the trocar was collected, and microscopic examination was performed.
Results:
When open circuits were formed with the intact insulation, the impedance was significantly reduced compared to the cases of closed circuits (142.0 Ω vs. 109.3 Ω, p = 0.040). When the power was 30 W and there was insulation failure, no significant difference was measured between the open circuit and the closed circuit (147.7 Ω vs. 130.7 Ω, p = 0.103). Collagen hyalinization, nuclear fragmentation, and coagulation necrosis suggesting burns were observed in the skin biopsy at the trocar insertion site.
Conclusion
This study demonstrated that even with a plastic trocar and electrosurgical instruments that have intact insulation, if an open circuit is formed, capacitive coupling increases, and trocar-site burn can occur. When using electrocautery, careful manipulation must be taken to avoid creating an open circuit to prevent capacitive coupling related to electrical skin burn.
8.Clinical and Radiological Features of Diffuse Lacrimal Gland Enlargement: Comparisons among Various Etiologies in 91 Biopsy-Confirmed Patients
Sae Rom CHUNG ; Gye Jung KIM ; Young Jun CHOI ; Kyung-Ja CHO ; Chong Hyun SUH ; Soo Chin KIM ; Jung Hwan BAEK ; Jeong Hyun LEE ; Min Kyu YANG ; Ho-Seok SA
Korean Journal of Radiology 2022;23(10):976-985
Objective:
To compare the clinical and radiological features of various etiologies of chronic diffuse lacrimal gland enlargement.
Materials and Methods:
We retrospectively reviewed 91 consecutive patients who underwent surgical biopsy for chronic diffuse lacrimal gland enlargement and were diagnosed with non-specific dacryoadenitis (DA) (n = 42), immunoglobulin G4-related dacryoadenitis (IgG4-RD) (n = 33), and lymphoma (n = 16). Data on patient demographics, clinical presentation, and CT imaging findings (n = 73) and MRI (n = 43) were collected. The following radiologic features of lacrimal gland enlargement were evaluated: size, unilaterality, wedge sign, angle with the orbital wall, heterogeneity, signal intensity, degree of enhancement, patterns of dynamic contrast-enhanced, and apparent diffusion coefficient value. Radiological features outside the lacrimal glands, such as extra-lacrimal orbital involvement and extra-orbital head and neck involvement, were also evaluated. The clinical and radiological findings were compared among the three diseases.
Results:
Compared to the DA and IgG4-RD groups, the lymphoma group was significantly older (mean 59.9 vs. 46.0 and 49.4 years, respectively; p = 0.001) and had a higher frequency of unilateral involvement (62.5% vs. 31.0% and 15.2%, respectively;p = 0.004). Compared to the IgG4-RD and lymphoma groups, the DA group had significantly smaller lacrimal glands (2.3 vs. 2.8 and 3.3 cm, respectively; p < 0.001) and a lower proportion of cases with a wedge sign (54.8% vs. 84.8% and 87.5%, respectively; p = 0.005). The IgG4-RD group showed more frequent involvement of the extra-orbital head and neck structures, including the infraorbital nerve (36.4%), paranasal sinus (72.7%), and salivary gland (58.6%) compared to the DA and lymphoma groups (4.8%–28.6%) (all p < 0.005).
Conclusion
Patient age, unilaterality, lacrimal gland size, wedge sign, and extra-orbital head and neck involvement differed significantly different between lymphoma, DA, and IgG4-RD. Our results will be useful for the differential diagnosis and proper management of chronic lacrimal gland enlargement.
9.The Effect of Integrated Nursing using Cognicise and Neurofeedback
Hee Wook WEON ; Gye Young HEO ; Jun Beom KIM ; Ji Eun SHIN ; Won Woo LEE ; Hae Kyoung SON
Korean Journal of Occupational Health Nursing 2020;29(2):114-122
Purpose:
This study aimed to identify the effect of integrated nursing using cognicise and neurofeedback on cognition and ⍺ waves among elderly individuals.
Methods:
This quasi-experimental single group pretest-posttest study included 29 Korean adults aged 65 years or older who participated at a senior welfare center in Y city from February to May 2019. Each integrated nursing session consisted of cognicise (10 minutes) and neurofeedback (20 minutes). Subjects participated twice a week for 10 weeks. Structured questionnaires to assess participants' general characteristics and the Korean version of the Mini-Mental Status Examination for Dementia Screening (K-MMSE-DS) were applied. Alpha waves were measured using BrainMaster.
Results:
Following the integrated nursing program, alpha waves improved in F3 (t=2.41, p=.023), C3 (t=3.00, p=.006), C4 (t=2.60, p=.015), P3 (t=2.43, p=.022), O1 (t=2.30, p=.029), T3 (t=3.05, p=.005), T4 (t=2.28, p=.030), T5 (t=2.91, p=.007), Fz (t=2.30, p=.029), Cz (t=2.73, p=.011), and Pz (t=2.23, p=.034). Most subjects experienced improvement in concentration after participating in the intervention.
Conclusion
This study provides evidence for the use of a neuroscientific approach including brain wave measurement to improve cognitive health among community-living elderly people.
10.Analysis of the Effects of the Implementation of Transfusion-Related Education for Nurses at Medical Institutions
Jinsook LIM ; Sae-Rom CHOI ; Chieeun SONG ; Yumi PARK ; Young Ae LIM ; Jun Nyun KIM ; Gye Cheol KWON
Korean Journal of Blood Transfusion 2020;31(3):222-229
Background:
Nurses play a central role in the process of blood transfusion because they have the closest interactions with patients. Providing nurses with the appropriate knowledge and competency through education can help ensure transfusion safety. This study investigated the effectiveness of the first nationwide transfusion-related education for nurses by analyzing questionnaires for a self-assessment of competency on transfusion-related knowledge before and after the education and general evaluation for the educational program.
Methods:
The education program was composed of four lectures and was conducted in seven regions in South Korea. One hundred and ninety-two nurses participated, and the questionnaires for 170 nurses were analyzed.
Results:
The participants consisted of 90 nurses (53.0%) from tertiary hospitals, 23 (13.5%) from general hospitals, and 57 (33.5%) from other hospitals. The majority of the participants (103/170, 60.6%) were from hospitals with ≥500 beds, and 69.4% had a work period of ≥10 years. The scores for pre-/post-education self-assessment of competency were as follows: blood components, 3.03/3.73; pretransfusion testing, 2.86/3.64; management of transfusion, 3.18/3.84; and transfusion reactions, 3.11/3.78. In all categories, there was a significant increase in the score after the education program. The majority of participants (99.4%) provided a positive response regarding the necessity of a transfusion-related education program.
Conclusion
South Korea’s first attempt at transfusion-related education for nurses showed a strong positive effect by improving participants’ transfusion-related competency. Considering the important role of nurses in blood transfusion, the educational program should continue and be expanded in the future.

Result Analysis