1.A study on fracture strength and color by the design of metal coping in ceramo metal crown.
Myung Ho LEE ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1992;30(1):103-124
No abstract available.
Crowns*
2.THREE-DIMENSIONAL COMPARISON OF FRAMEWORK DISPLACEMENTS JOINED BY VARIOUS CONNECTION TECHNIQUES.
Jang Seop LIM ; Young Chan JEON ; Chang Mo JEONG
The Journal of Korean Academy of Prosthodontics 1999;37(3):358-374
This study measured the relative displacements of the five-unit fixed partial dentures as cast with the same fixed partial dentures sectioned and assembled by investment-soldering, soldering stand-soldering, and cast-joining techniques. A total of fifteen specimens using a type IV gold alloy wee one-piece cast as control and then sectioned and assembled five test specimens for each method were prepared. A computerized three dimensional coordinate measuring machine and specially designed cylinder for this study were used. Displacement was defined by six displacement variables for the each of cylinders incorporated in each casting: three component displacements ( Lx, Ly, and Lz) and rotational displacements( thetax, thetay, thetaz). The global displacement was computed using the mathematical formula R= Global displacement ={{{{rm SQRT { (x'-x)^2 +(y'-y)^2 + (z'-z)^2} }} }} Under the conditions of this study, the following conclusions were drawn: 1. The investment-soldering group showed the largest mean value of final global displacements, followed by stand-soldering group, cast-joining group and one-piece cast group. However, between the mean values of final global displacement for the cast-joining group and one-piece cast group, there was no significant difference. 2. For investment-soldering and stand-soldering groups, the greater global displacements were recorded in soldering phase than in indexing or investing phase. 3. For one-piece cast group, the displacements occured mostly in the casting phase. And for castjoining group, there was no significant difference in global displacements among the fabrication procedures. 4. Intercentroidal distance decreased in framework-pattering, solder-indexing, solder-standing, and soldering phases, but increased in investment block-investing and casting phases. 5. Specially designed cylinder for touch-trigger type coordinate measuring machine was validated.
Abstracting and Indexing as Topic
;
Alloys
;
Denture, Partial, Fixed
;
Investments
;
Methods
3.A MEASUREMENT OF DISPLACEMENTS OF CAST FRAMEWORK BY TORCH SOLDERING AND ELECTRIC SOLDERING TECHNIQUES.
Sang Won JEON ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(6):791-799
The purpose of this study was to investigate the displacements of cast framework by torch soldering and electric soldering techniques. Specimen had two cylinders and connecting bar that had sectioned with 0.3mm gap at mid point. 10 of total specimens were divided into two groups. In torch soldered group, soldering investment block was made and conventional torch soldering procedure was carried out. In electric soldered group, electric soldering was carried out on the master cast without soldering investment block by using electric soldering machine(Dentapunkt DP 7, Kulzer, Germany). After soldering procedure, three dimensional coordinates of two centroids of each cylinder were measured by three dimensional coordinate measuring machine. The intercentroidal displacement and global displacement were calculated and then, these values were compared and evaluated. The results were obtained as follows: 1. Intercentroidal distances of specimens decreased after both soldering procedures, and the decrease in intercentroidal distance was greater for torch soldered group than for electric soldered group 2. Global displacements of torch soldered group were greater than those of electric soldered group
Investments
4.MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY.
Hi Chan JUNG ; Chang Mo JEONG ; Young Chan JEON ; Jang Seop LIM
The Journal of Korean Academy of Prosthodontics 2000;38(2):214-225
The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials (plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment (Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by x 100 compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer. 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials 00.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(p>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.
Alloys*
;
Ceramics
;
Crowns*
;
Investments
;
Plastics
;
Telescopes*
5.Fracture strength of zirconia monolithic crowns and metal-ceramic crowns after cyclic loading and thermocycling.
Sang Min LEE ; Hee Chan JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 2007;45(1):12-20
PURPOSE: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm). MATERIAL AND METHOD: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling (5-55degrees C, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups'fracture load before and after cyclic loading. RESULTS: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. CONCLUSION: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.
Axis, Cervical Vertebra
;
Crowns*
;
Resin Cements
6.A study of precise fit of the CAM zirconia all-ceramic framework.
Mi Hyeon JEON ; Young Chan JEON ; Chang Mo JEONG ; Jang Seop LIM ; Hee Chan JEONG
The Journal of Korean Academy of Prosthodontics 2005;43(5):611-621
STATE OF PROBLEM: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. PURPOSE: This study was to evaluate the fit of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). MATERIAL AND METHOD: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesiodistal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e. mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of * 100. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. RESULTS AND CONCLUSION: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia(81.9 micrometer) and metal(81.3 micrometer) framework and internal marginal gaps of zirconia(44.6 micrometer) were smaller than those of metal framework(58.6 micrometer). 2. Internal axial gaps of zirconia framework(96.7 micrometer) were larger than those of metal framework(78.1 micrometer) significantly and adversely, internal occlusal gaps of zirconia framework(89.4 micrometer) were smaller than those of metal framework(104.9 micrometer) significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.
Alloys
;
Bicuspid
;
Dentistry
;
Glass
;
Molar
;
Shoulder
7.A case of benign recurrent intrahepatic cholestasis.
Jae Hong PARK ; Sung Sub SIM ; Soo Young KIM ; Hee Joo JEON ; Chan Yung KIM
Journal of the Korean Pediatric Society 1991;34(12):1745-1752
No abstract available.
Cholestasis, Intrahepatic*
8.Effects of B-16 Melanoma Cells and Mycoplasma pneumoniae on the Induction of IL-1 beta, IL-2, IL-6, IL-10, IL-12, and TNF - alpha from Mouse Astrocytes.
Tae Young KIM ; Byung Chan JEON ; Hwa Dong LEE ; Myung Woong CHANG
Journal of Bacteriology and Virology 2001;31(1):1-10
No abstract available.
Animals
;
Astrocytes*
;
Interleukin-1*
;
Interleukin-10*
;
Interleukin-12*
;
Interleukin-1beta*
;
Interleukin-2*
;
Interleukin-6*
;
Melanoma*
;
Mice*
;
Mycoplasma pneumoniae*
;
Mycoplasma*
;
Pneumonia, Mycoplasma*
9.Giant-Cell Tumor of the Middle Cranial Fossa.
Young Su KIM ; Byung Chan JEON
Journal of Korean Neurosurgical Society 2003;34(5):484-486
The authors report a case of giant-cell tumor of the right middle cranial fossa floor a 43-year-old man. His presentation, characteristic magnetic resonance image findings, treatment, and 2-year follow-up result are described. The patient about this rare neoplasm of the skull base are also reviewed.
Adult
;
Cranial Fossa, Middle*
;
Follow-Up Studies
;
Humans
;
Skull Base
10.Cytokine Levels in Cerebrospinal Fluid and Delayed Ischemic Deficits in Patients with Aneurysmal Subarachnoid Hemorrhage.
Ki Young KWON ; Byung Chan JEON
Journal of Korean Medical Science 2001;16(6):774-780
Subarachnoid hemorrhage (SAH) induces an inflammatory reaction and may lead to ischemic brain damage. The pathogenesis of brain dysfunction and delayed ischemic symptoms remain difficult to understand despite extensive surveys of such reactions. Cytokine production in the central nervous system following SAH and its relation with clinical outcome have hardly been studied. This study was aimed to determine whether the levels of IL-1 beta, IL-6 and TNF-alpha in the initial cerebrospinal fluid would increase following aneurysmal SAH, and be related with development of delayed ischemic deficit and clinical outcome. Nineteen patients suffering from aneurysmal SAH and 12 control volunteers were the subjects in this study. Cerebrospinal fluid samples were obtained on admission and the levels of each cytokine were determined with enzyme-linked immunosorbent assay. Patients with aneurysmal subarachnoid hemorrhage showed elevated levels of IL-1 beta, and TNF-alpha on admission. The patients with poor neurological status showed high levels of IL-1 beta, and IL-6. The patients who developed delayed ischemic deficit had high level of IL-6. We suggest that elevated level of IL-6 in cerebrospinal fluid of patients with aneurysmal SAH on admission can predict the high risk of delayed ischemic deficit.
Adult
;
Aged
;
Brain Ischemia/*cerebrospinal fluid/*diagnosis/immunology
;
Cytokines/*cerebrospinal fluid
;
Female
;
Glasgow Outcome Scale
;
Human
;
Interleukin-1/cerebrospinal fluid
;
Interleukin-6/cerebrospinal fluid
;
Male
;
Middle Age
;
Predictive Value of Tests
;
Subarachnoid Hemorrhage/*cerebrospinal fluid/*diagnosis/immunology
;
Tumor Necrosis Factor/cerebrospinal fluid