1.A study on fracture strength and color by the design of metal coping in ceramo metal crown.
Myung Ho LEE ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1992;30(1):103-124
No abstract available.
Crowns*
2.THREE-DIMENSIONAL COMPARISON OF FRAMEWORK DISPLACEMENTS JOINED BY VARIOUS CONNECTION TECHNIQUES.
Jang Seop LIM ; Young Chan JEON ; Chang Mo JEONG
The Journal of Korean Academy of Prosthodontics 1999;37(3):358-374
This study measured the relative displacements of the five-unit fixed partial dentures as cast with the same fixed partial dentures sectioned and assembled by investment-soldering, soldering stand-soldering, and cast-joining techniques. A total of fifteen specimens using a type IV gold alloy wee one-piece cast as control and then sectioned and assembled five test specimens for each method were prepared. A computerized three dimensional coordinate measuring machine and specially designed cylinder for this study were used. Displacement was defined by six displacement variables for the each of cylinders incorporated in each casting: three component displacements ( Lx, Ly, and Lz) and rotational displacements( thetax, thetay, thetaz). The global displacement was computed using the mathematical formula R= Global displacement ={{{{rm SQRT { (x'-x)^2 +(y'-y)^2 + (z'-z)^2} }} }} Under the conditions of this study, the following conclusions were drawn: 1. The investment-soldering group showed the largest mean value of final global displacements, followed by stand-soldering group, cast-joining group and one-piece cast group. However, between the mean values of final global displacement for the cast-joining group and one-piece cast group, there was no significant difference. 2. For investment-soldering and stand-soldering groups, the greater global displacements were recorded in soldering phase than in indexing or investing phase. 3. For one-piece cast group, the displacements occured mostly in the casting phase. And for castjoining group, there was no significant difference in global displacements among the fabrication procedures. 4. Intercentroidal distance decreased in framework-pattering, solder-indexing, solder-standing, and soldering phases, but increased in investment block-investing and casting phases. 5. Specially designed cylinder for touch-trigger type coordinate measuring machine was validated.
Abstracting and Indexing as Topic
;
Alloys
;
Denture, Partial, Fixed
;
Investments
;
Methods
3.A MEASUREMENT OF DISPLACEMENTS OF CAST FRAMEWORK BY TORCH SOLDERING AND ELECTRIC SOLDERING TECHNIQUES.
Sang Won JEON ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(6):791-799
The purpose of this study was to investigate the displacements of cast framework by torch soldering and electric soldering techniques. Specimen had two cylinders and connecting bar that had sectioned with 0.3mm gap at mid point. 10 of total specimens were divided into two groups. In torch soldered group, soldering investment block was made and conventional torch soldering procedure was carried out. In electric soldered group, electric soldering was carried out on the master cast without soldering investment block by using electric soldering machine(Dentapunkt DP 7, Kulzer, Germany). After soldering procedure, three dimensional coordinates of two centroids of each cylinder were measured by three dimensional coordinate measuring machine. The intercentroidal displacement and global displacement were calculated and then, these values were compared and evaluated. The results were obtained as follows: 1. Intercentroidal distances of specimens decreased after both soldering procedures, and the decrease in intercentroidal distance was greater for torch soldered group than for electric soldered group 2. Global displacements of torch soldered group were greater than those of electric soldered group
Investments
4.MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY.
Hi Chan JUNG ; Chang Mo JEONG ; Young Chan JEON ; Jang Seop LIM
The Journal of Korean Academy of Prosthodontics 2000;38(2):214-225
The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials (plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment (Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by x 100 compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer. 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials 00.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(p>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.
Alloys*
;
Ceramics
;
Crowns*
;
Investments
;
Plastics
;
Telescopes*
5.Fracture strength of zirconia monolithic crowns and metal-ceramic crowns after cyclic loading and thermocycling.
Sang Min LEE ; Hee Chan JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 2007;45(1):12-20
PURPOSE: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm). MATERIAL AND METHOD: Twelve crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system (Kavo, Germany) and twelve crowns for each of 2 metal-ceramic crown groups were made by the conventional method. All crowns were luted to the metal dies using resin cement. Half of the specimens were exposed to thermocycling (5-55degrees C, 1 Hz) and cyclic loading (300,000 cycles, 50N). Subsequently, all crowns were mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test (P<.05) were used for statistical analysis of all groups, and paired t-test (P<.05) was followed for statistical comparison between each groups'fracture load before and after cyclic loading. RESULTS: 1. The fracture strength of the zirconia monolithic crowns and the metal-ceramic crown increased as thickness increased (P<.05). 2. The cyclic loading and thermocycling significantly decreased the fracture strength of the zirconia monolithic crowns (P<.05). 3. The standard deviation of fracture strength of the zirconia monolithic crowns was very low. CONCLUSION: The fracture strength of the zirconia monolithic crowns for the posterior area tends to be higher with thickness increased and 0.8mm or over in thickness is recommended to have similar or over the fracture strength of metal-ceramic crowns.
Axis, Cervical Vertebra
;
Crowns*
;
Resin Cements
6.A study of precise fit of the CAM zirconia all-ceramic framework.
Mi Hyeon JEON ; Young Chan JEON ; Chang Mo JEONG ; Jang Seop LIM ; Hee Chan JEONG
The Journal of Korean Academy of Prosthodontics 2005;43(5):611-621
STATE OF PROBLEM: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. PURPOSE: This study was to evaluate the fit of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). MATERIAL AND METHOD: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesiodistal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e. mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of * 100. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. RESULTS AND CONCLUSION: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia(81.9 micrometer) and metal(81.3 micrometer) framework and internal marginal gaps of zirconia(44.6 micrometer) were smaller than those of metal framework(58.6 micrometer). 2. Internal axial gaps of zirconia framework(96.7 micrometer) were larger than those of metal framework(78.1 micrometer) significantly and adversely, internal occlusal gaps of zirconia framework(89.4 micrometer) were smaller than those of metal framework(104.9 micrometer) significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.
Alloys
;
Bicuspid
;
Dentistry
;
Glass
;
Molar
;
Shoulder
7.COLORIMETRIC ANALYSIS OF COLOR DIFFERENCES BETWEEN DENTIN PORCELAINS.
Chang Seop KIM ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(4):425-432
The purpose of this study is to evaluate the color differences that can exist between differnet brands of dentin porcelain having identical shade designations. The instrumental colorimetric technique was used to determine these differences. The three brands of dentin porcelain used were Vita VMK-68, Shofu Vintage, and Ceramco II. The three shades selected were the Vita Lumin shades A2, B2, and C2. The color difference values were compared with each other using L*, a*, b*, three variables of the CIELAB color system, and E. The results of this study were as follows: 1. Corresponding shades of different brands of dentin porcelain produced different L*, a*, b* values. 2. The greatest E value in corresponding shade was found to exist between Ceramco II and Shofu Vintage, followed by between Vita VMK-68 and Ceramco II, and then between Vita VMK-68 and Shofu Vintage. 3. The E values in shade C2 were mainly influenced by L* value ; however none of L*, a*, b* values had greater influence on E values than the others in shade A2, B2. 4. Shofu Vintage had the highest b* value, followed by Vita VMK-68, and then Ceramco II.
Dental Porcelain*
;
Dentin*
8.MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE.
The Journal of Korean Academy of Prosthodontics 1998;36(1):120-132
This stusy was to investigate the marginal fitness of porcelain-fused-to-metal crown after succesive firing cycle. Main variables were the degree of marginal curvature of labiocervical margin and the type of alloy. The exaggerated marginal curvature(EMC) was created by additional reduction at the faciocervical wall of the normallized marginal curvature (NMC)-typed ivorine tooth by using milling machine. The difference in the shape was the mid facial margin was placed 2mm apical to cemento-enamel junction in labial surface. Three types of alloy were high noble, noble, and base metal alloy. Test specimens were divided into 8 groups and each group had 8 specimens. Sixty four ceramometal crowns were made totally. Measurement stages were following degassing, opaquing, body porcelain firing, and glazing, and measuring sites were 4.(midmesial, midfacial, middistal, and midlingual). Digital, travelling measuring microscope (0.5 um precision, Olympus, Japan) was used underx250 magnification. Within the limitation of this investigation, it was concluded as belows: 1. The pattern of marginal distortion was varied. Degassing stage was not a specific, causative stage that induce most of total marginal distortion during whole procedure fabricating a ceramometal crown. Body firing stage induced discrepancy relatively more than other firing stages. 2. The specimens that were Ni-based alloy and had EMC were distorted persistently following successive fabricating procedures. But marginal openings were decreased after glazing. 3. The release of metal grinding-induced stress was presumed as a cause that induce marginal distortion. 4. The amount of discrepancies of the labial and lingual margins were greater than that of the mesial and distal margin in the specimen that had EMC. 5. Silver-plated die was not enough to resist abrasion during repeated seating of metal copings on the die-holding device.
Alloys
;
Crowns*
;
Dental Porcelain
;
Fires
;
Tooth
9.THE INFLUENCE OF WATTAGE AND CURING TIME OF MICROWAVE ENERGY ON PHYSICAL PROPERTIES OF THE DENTURE BASE RESIN.
Dae Sung JEONG ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(6):767-775
The purpose of this study was to evaluate the effect of wattage and curing time on surface hardness, three-point bending strength and internal porosity of microwave curing denture base resin. Two sizes of resin spicimens were made of Acron MC ; 3.5x10x60mm for surface hardness and three-point bending strength measurement and 5x12x60mm for internal porosity measurement. They were cured by microwave energy at varing wattages(500W, 700W) and curing times(2min., 3min., 4min.) to determine if a certain wattage/curing time combination would improve physical properties. Surface hardness was measured with Vikers hardness tester, three-point bend-ing strength with universal testing machine and internal porosity was calculated by measuring the weight in air and in water. The results obtained were as follows : 1. There was no significant difference in percent porosity among experimental groups(p>0.05). 2. 500W/3min, group showed the higher surface hardness than 700W/2, 3, 4min. groups(p<0.05), and 700W/4 min. group showed the lower surface hardness than 500W/2, 3, 4min. groups(p<0.05), but there was no significant difference among others(p>0.05). 3. 500W/3min. group yielded the higher value of bending strength than 500W/2min., 700W/3, 4min. groups(p<0.05), but there was no significant difference among others(p>0.05).
Denture Bases*
;
Dentures*
;
Hardness
;
Hardness Tests
;
Microwaves*
;
Polymethyl Methacrylate
;
Porosity
;
Water
10.A STUDY FOR SETTING AND THERMAL EXPANSION OF DENTAL SOLDERING INVESTMENTS.
Sung Ae SHIN ; Jang Seop LIM ; Chang Mo JEONG ; Young Chan JEON
The Journal of Korean Academy of Prosthodontics 1999;37(6):730-740
The purpose of this study was to investigate setting and thermal expansion of dental soldering investments. In order to compare expansion rates and to investigate the effect of water/powder ratio on expansion, setting and thermal expansion of four dental soldering investments were measured under three different water/powder ratio conditions: standard, 20% decreased and 20% increased. Setting expansion of investments was measured by use of dialgauge method. Each measurement was started two minutes later from the beginning of spatulation and recorded every one minute for one hour. Thermal expansion of cylindrical test specimens, 10mm diameter, 50mm length, was recorded in a Thermodilatometer at heating rate of 10degrees C per minute from 25degrees C to 700degrees C. The results of this study were obtained as follows: 1. Setting expansion rates under the standard water/power ratio condition were 0.198% in Speed-E, 0.090% in Deguvest, 0.080% in CM and Hi-temp. Setting expansion of Speed-E was significantly different from those of CM, Deguvest and Hi-temp, and setting expansion of Deguvest was significantly different from those of CM and Hi-temp(p<.05). 2. Under the decreased water/powder ratio condition, there was significant increase in setting expansion of 4 dental soldering investments(p<.05). 3. There were no significant differences in setting expansions of investments except Hi-temp between standard and increased water/powder ratio condition(p<.05). 4. Thermal expansion rates under the standard water/powder ratio condition were 1.923% in Deguvest, 1.629% in Speed-E, 1.619% in Hi-temp and 1.580% in CM. No significant difference in thermal expansions under the standard water/powder ratio condition existed only between Speed-E and Hi-temp(p<.05). 5. Under the decreased water/powder ratio condition, there was significant increase in thermal expansion of CM and Deguvest but decrease in thermal expansion of Speed-E(p<.05). 6. Under the increased water/powder ratio condition, there was significant decrease in thermal expansion of CM, Deguvest and Speed-E but decrease in thermal expansion of Hi-temp(p<.05).
Dental Soldering*
;
Heating
;
Hot Temperature
;
Investments*
Result Analysis