1.Difficulties in diagnosis and treatment of pyogenic liver abscess
Youhai YU ; Xuliang CHEN ; Shaohua SHI ; Shusen ZHENG
Chinese Journal of Hepatobiliary Surgery 2022;28(6):477-480
Klebsiella pneumoniae liver abscess accompanied by metastatic infectious complications was firstly reported in 1986. The pathogen was defined as Hypervirulent K. pneumoniae (hvKp) after a series of studies, which is an evolving pathotype and more virulent than classical K. pneumoniae (cKp). At present, it is difficult to distinguish hvKp and cKp in the clinical microbiology lab, which results in delay in early diagnosis and treatment on hvKp-related infections. Biliary tract diseases after cholangiojejunostomy, biliary interventional therapy and liver transplantation have become common causes of recurrent acute cholangitis. The incidence of bacterial liver abscess is on the rise, especially the infection caused by multidrug-resistant bacteria. This article reviews difficulties in the diagnosis and treatment of bacterial liver abscess.
2. Correlation between cone beam computed tomography-guided scheme and setup errors in nasopharyngeal carcinoma
Yibiao CHEN ; Hanxiong ZHANG ; Zhendong JIANG ; Haidong YU ; Tianbin MA ; Aihui CHEN ; Youhai XIE ; Jian ZHANG ; Ting LIU
Cancer Research and Clinic 2018;30(8):521-525
Objective:
To study the more safe and accurate guidance scheme of cone beam computed tomography (CBCT) in nasopharyngeal carcinoma.
Methods:
CBCT was regularly performed on 87 patients with nasopharyngeal carcinoma in Meizhou People's Hospital from November 2014 to August 2015. For each patient, 10 times CBCT scans were obtained pre-treatment. All the setup errors were obtained and analysed on the orientation X (left and right), Y (head and foot) and Z (vertical) axis.
Results:
With the increase of the number of CBCT scans, there was no statistically significant difference among the mean setup errors of the 10 times scans in X (left and right) and Y (head and foot) directions (all
3.Planning target volume margin based on the image-guided radiotherapy in nasopharyngeal carcinoma
Yibiao CHEN ; Hanxiong ZHANG ; Zhendong JIANG ; Haidong YU ; Tianbin MA ; Aihui CHEN ; Youhai XIE ; Jian ZHANG ; Ting LIU ; Wenbiao ZHU
Cancer Research and Clinic 2018;30(3):180-183,189
Objective To analyze set-up errors for irradiation of nasopharyngeal carcinoma by using kilo-voltage cone beam computed tomography (kV-KBCT) scanning, and to calculate the external margin from planning target volume (PTV) of nasopharyngeal carcinoma. Methods A total of 150 nasopharyngeal carcinoma patients in Meizhou People's Hospital from December 2014 to November 2016 were treated by image-guided radiation therapy (IGRT), kV-KBCT, CT image scanning matcthed by bone and grey alignment. PTV of nasopharyngeal carcinoma was also calculated. Results According to PTV formula, the external distance before radiotherapy guided by grey alignment was 0.5 mm in X-axis, 0.4 mm in Y-axis, 0.8 mm in Z-axis. While the distance was 0.1 mm in X-axis, 0.5 mm in Y-axis, 1.7 mm in Z-axis guided by bone alignment. After radiotherapy, the external distance guided by grey alignment was 0.4 mm in X-axis, 0.5 mm in Y-axis, 0.9 mm in Z-axis. While the distance was 0.1 mm in X-axis, 0.9 mm in Y-axis, 2.0 mm in Z-axis guided by bone alignment. There was no significant difference in set-up errors of 3 directions and 2 aligned ways before and after treatment.Conclusions The PTV within 3 mm is safe when IGRT is used for directing radiotherapy of nasopharyngeal carcinoma,and kV-KBCT is an effective image equipment.