1.Association between preoperative oxygen reserve index and postoperative pulmonary complications: a prospective observational study
Sangho LEE ; Halin HONG ; Hyojin CHO ; Sang-Wook LEE ; Ann Hee YOU ; Hee Yong KANG ; Sung Wook PARK ; Mi Kyeong KIM ; Jeong-Hyun CHOI
Korean Journal of Anesthesiology 2025;78(3):224-235
Background:
The oxygen reserve index (ORi) noninvasively measures oxygen levels within the mild hyperoxia range. To evaluate whether a degree of increase in the ORi during preoxygenation for general anesthesia is associated with the occurrence of postoperative pulmonary complications (PPCs).
Methods:
We enrolled 154 patients who underwent preoperative pulmonary function tests and were scheduled for elective surgery under general anesthesia. We aimed to measure the increase in ORi during preoxygenation before general anesthesia and analyze its association with PPCs.
Results:
PPCs occurred in 76 (49%) participants. Multivariate logistic regression analysis revealed that the three-minute preoxygenation ORi was significantly associated with PPCs (Odds ratio [OR]: 0.02, 95% CI [0.00–0.16], P < 0.001). The areas under the curve (AUC [95% CI]) in the receiver operating characteristic curve analysis for the three-minute preoxygenation ORi for PPCs were 0.64 (0.55–0.73). After a subgroup analysis, multivariate logistic regression showed that the three-minute preoxygenation ORi was significantly associated with PPCs among patients who underwent thoracic surgery (OR: 0.01, 95% CI [0.00–0.19], P = 0.006). The AUC of the three-minute preoxygenation ORi for PPCs was 0.72 (0.57–0.86) in patients who underwent thoracic surgery.
Conclusions
A low ORi measured after 3 min of preoxygenation for general anesthesia was associated with an increased risk of PPCs, including those undergoing thoracic surgery. This study demonstrated the potential of ORi, measured after oxygen administration, as a tool for evaluating lung function that complements traditional lung function tests and scoring systems.
2.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
3.Association between preoperative oxygen reserve index and postoperative pulmonary complications: a prospective observational study
Sangho LEE ; Halin HONG ; Hyojin CHO ; Sang-Wook LEE ; Ann Hee YOU ; Hee Yong KANG ; Sung Wook PARK ; Mi Kyeong KIM ; Jeong-Hyun CHOI
Korean Journal of Anesthesiology 2025;78(3):224-235
Background:
The oxygen reserve index (ORi) noninvasively measures oxygen levels within the mild hyperoxia range. To evaluate whether a degree of increase in the ORi during preoxygenation for general anesthesia is associated with the occurrence of postoperative pulmonary complications (PPCs).
Methods:
We enrolled 154 patients who underwent preoperative pulmonary function tests and were scheduled for elective surgery under general anesthesia. We aimed to measure the increase in ORi during preoxygenation before general anesthesia and analyze its association with PPCs.
Results:
PPCs occurred in 76 (49%) participants. Multivariate logistic regression analysis revealed that the three-minute preoxygenation ORi was significantly associated with PPCs (Odds ratio [OR]: 0.02, 95% CI [0.00–0.16], P < 0.001). The areas under the curve (AUC [95% CI]) in the receiver operating characteristic curve analysis for the three-minute preoxygenation ORi for PPCs were 0.64 (0.55–0.73). After a subgroup analysis, multivariate logistic regression showed that the three-minute preoxygenation ORi was significantly associated with PPCs among patients who underwent thoracic surgery (OR: 0.01, 95% CI [0.00–0.19], P = 0.006). The AUC of the three-minute preoxygenation ORi for PPCs was 0.72 (0.57–0.86) in patients who underwent thoracic surgery.
Conclusions
A low ORi measured after 3 min of preoxygenation for general anesthesia was associated with an increased risk of PPCs, including those undergoing thoracic surgery. This study demonstrated the potential of ORi, measured after oxygen administration, as a tool for evaluating lung function that complements traditional lung function tests and scoring systems.
4.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
5.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
6.Association between preoperative oxygen reserve index and postoperative pulmonary complications: a prospective observational study
Sangho LEE ; Halin HONG ; Hyojin CHO ; Sang-Wook LEE ; Ann Hee YOU ; Hee Yong KANG ; Sung Wook PARK ; Mi Kyeong KIM ; Jeong-Hyun CHOI
Korean Journal of Anesthesiology 2025;78(3):224-235
Background:
The oxygen reserve index (ORi) noninvasively measures oxygen levels within the mild hyperoxia range. To evaluate whether a degree of increase in the ORi during preoxygenation for general anesthesia is associated with the occurrence of postoperative pulmonary complications (PPCs).
Methods:
We enrolled 154 patients who underwent preoperative pulmonary function tests and were scheduled for elective surgery under general anesthesia. We aimed to measure the increase in ORi during preoxygenation before general anesthesia and analyze its association with PPCs.
Results:
PPCs occurred in 76 (49%) participants. Multivariate logistic regression analysis revealed that the three-minute preoxygenation ORi was significantly associated with PPCs (Odds ratio [OR]: 0.02, 95% CI [0.00–0.16], P < 0.001). The areas under the curve (AUC [95% CI]) in the receiver operating characteristic curve analysis for the three-minute preoxygenation ORi for PPCs were 0.64 (0.55–0.73). After a subgroup analysis, multivariate logistic regression showed that the three-minute preoxygenation ORi was significantly associated with PPCs among patients who underwent thoracic surgery (OR: 0.01, 95% CI [0.00–0.19], P = 0.006). The AUC of the three-minute preoxygenation ORi for PPCs was 0.72 (0.57–0.86) in patients who underwent thoracic surgery.
Conclusions
A low ORi measured after 3 min of preoxygenation for general anesthesia was associated with an increased risk of PPCs, including those undergoing thoracic surgery. This study demonstrated the potential of ORi, measured after oxygen administration, as a tool for evaluating lung function that complements traditional lung function tests and scoring systems.
7.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
8.Association between preoperative oxygen reserve index and postoperative pulmonary complications: a prospective observational study
Sangho LEE ; Halin HONG ; Hyojin CHO ; Sang-Wook LEE ; Ann Hee YOU ; Hee Yong KANG ; Sung Wook PARK ; Mi Kyeong KIM ; Jeong-Hyun CHOI
Korean Journal of Anesthesiology 2025;78(3):224-235
Background:
The oxygen reserve index (ORi) noninvasively measures oxygen levels within the mild hyperoxia range. To evaluate whether a degree of increase in the ORi during preoxygenation for general anesthesia is associated with the occurrence of postoperative pulmonary complications (PPCs).
Methods:
We enrolled 154 patients who underwent preoperative pulmonary function tests and were scheduled for elective surgery under general anesthesia. We aimed to measure the increase in ORi during preoxygenation before general anesthesia and analyze its association with PPCs.
Results:
PPCs occurred in 76 (49%) participants. Multivariate logistic regression analysis revealed that the three-minute preoxygenation ORi was significantly associated with PPCs (Odds ratio [OR]: 0.02, 95% CI [0.00–0.16], P < 0.001). The areas under the curve (AUC [95% CI]) in the receiver operating characteristic curve analysis for the three-minute preoxygenation ORi for PPCs were 0.64 (0.55–0.73). After a subgroup analysis, multivariate logistic regression showed that the three-minute preoxygenation ORi was significantly associated with PPCs among patients who underwent thoracic surgery (OR: 0.01, 95% CI [0.00–0.19], P = 0.006). The AUC of the three-minute preoxygenation ORi for PPCs was 0.72 (0.57–0.86) in patients who underwent thoracic surgery.
Conclusions
A low ORi measured after 3 min of preoxygenation for general anesthesia was associated with an increased risk of PPCs, including those undergoing thoracic surgery. This study demonstrated the potential of ORi, measured after oxygen administration, as a tool for evaluating lung function that complements traditional lung function tests and scoring systems.
9.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
10.Evaluation of Burnout and Contributing Factors in Imaging Cardiologists in Korea
You-Jung CHOI ; Kang-Un CHOI ; Young-Mee LEE ; Hyun-Jung LEE ; Inki MOON ; Jiwon SEO ; Kyu KIM ; So Ree KIM ; Jihoon KIM ; Hong-Mi CHOI ; Seo-Yeon GWAK ; Minkwan KIM ; Minjeong KIM ; Kyu-Yong KO ; Jin Kyung OH ; Jah Yeon CHOI ; Dong-Hyuk CHO ; On behalf of the Korean Society of Echocardiography Heart Imagers of Tomorrow
Journal of Korean Medical Science 2024;40(5):e21-
Background:
We aimed to examine the prevalence of burnout among imaging cardiologists in Korea and to identify its associated factors.
Methods:
An online survey of imaging cardiologists affiliated with university hospitals in Korea was conducted using SurveyMonkey ® in November 2023. The validated Korean version of the Maslach Burnout Inventory-Human Service Survey was used to assess burnout across three dimensions: emotional exhaustion, depersonalization, and lack of personal accomplishment. Data on demographics, work environment factors, and job satisfaction were collected using structured questionnaires.
Results:
A total of 128 imaging cardiologists (46.1% men; 76.6% aged ≤ 50 years) participated in the survey. Regarding workload, 74.2% of the respondents interpreted over 50 echocardiographic examinations daily, and 53.2% allocated > 5 of 10 working sessions per week to echocardiographic laboratory duties. Burnout levels were high, with a significant proportion of participants experiencing emotional exhaustion (28.1%), depersonalization (63.3%), and a lack of personal accomplishment (92.2%). Younger age (< 50 years) was correlated with higher emotional exhaustion risk, while more research time was protective against burnout in the depersonalization domain. Factors, such as being single, living with family, and specific job satisfaction facets, including uncontrollable workload and value mismatch, were associated with varying levels of burnout risk across different dimensions
Conclusion
Our study underscores the high burnout rates among Korean imaging cardiologists, attributed to factors such as the subjective environment and job satisfaction.Hence, evaluating and supporting cardiologists in terms of individual values and subjective factors are important to effectively prevent burnout..

Result Analysis
Print
Save