1.Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading.
Manish MISHRA ; Shogo OZAWA ; Tatsuhiko MASUDA ; Fumi YOSHIOKA ; Yoshinobu TANAKA
The Journal of Advanced Prosthodontics 2011;3(3):140-144
PURPOSE: Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading. MATERIALS AND METHODS: Two dimensional finite element models of cylinderical implant, abutments and bone made by titanium or polyoxymethylene were simulated with the aid of Marc/Mentat software. Each model represented bone, implant and titanium or polyoxymethylene abutment. Model 1: Implant with 3 mm titanium abutment, Model 2: Implant with 2 mm polyoxymethylene resilient material abutment, Model 3: Implant with 3 mm polyoxymethylene resilient material abutment and Model 4: Implant with 4 mm polyoxymethylene resilient material abutment. A vertical load of 11 N was applied with a frequency of 2 cycles/sec. The stress distribution pattern and displacement at the junction of cortical bone and implant was recorded. RESULTS: When Model 2, 3 and 4 are compared with Model 1, they showed narrowing of stress distribution pattern in the cortical bone as the height of the polyoxymethylene resilient material abutment increases. Model 2, 3 and 4 showed slightly less but similar displacement when compared to Model 1. CONCLUSION: Within the limitation of this study, we conclude that introduction of different height resilient material abutment with different heights i.e. 2 mm, 3 mm and 4 mm polyoxymethylene, does not bring about significant change in stress distribution pattern and displacement as compared to 3 mm Ti abutment. Clinically, with the application of resilient material abutment there is no significant change in stress distribution around implant-bone interface.
Dental Implants
;
Displacement (Psychology)
;
Finite Element Analysis
;
Titanium
2.Posterior Fixation of a Cervical Fracture Using the RRS Loop Spine System and Polyethylene Tape in an Elderly Ankylosing Spondylitis Patient: A Case Report.
Munehisa KOIZUMI ; Jin IIDA ; Hideki SHIGEMATSU ; Nobuhisa SATOH ; Masato TANAKA ; Tomohiko KURA ; Shinji TSUKAMOTO ; Yoshinobu KATO ; Yasuhito TANAKA
Asian Spine Journal 2012;6(1):60-65
An 80-year-old woman presented with neck pain and paraparesis of Frankel C in her upper and lower extremities after falling. Imaging revealed an ankylosing cervical spine and a fracture line running obliquely from the anterior C3-4 to the posterior C4-5 level. Posterior fixation from the occi pit to T3 was performed using the RRS Loop Spine System and concomitant polyethylene tape fixation. This system is characterized by the uniqueness of how it screws to the occi pit and its use of a fixation rod with a larger diameter than in other instrumentation devices for use in the cervical region. Sublaminar banding using polyethylene tape was used to secure fixation. Her postoperative course was unremarkable, and her neck pain was relieved, although neurological improvement was minor. To our knowledge, this is the first report of an application of the RRS Loop Spine System to an ankylosing spondylitis patient with a cervical fracture.
Aged
;
Aged, 80 and over
;
Female
;
Humans
;
Lower Extremity
;
Neck Pain
;
Paraparesis
;
Polyethylene
;
Running
;
Spine
;
Spondylitis, Ankylosing
3.Preliminary Screening Method for Low Bone Mineral Density Using a Self-Reported Questionnaire among Peri- and Postmenopausal Women
Yudai YANO ; Eiichiro IWATA ; Takuya SADA ; Yuki UENO ; Yoshinobu HYAKUDA ; Sachiko KAWASAKI ; Akinori OKUDA ; Hideki SHIGEMATSU ; Kota UEMATSU ; Hiroshi YAJIMA ; Yasuhito TANAKA
Asian Spine Journal 2022;16(6):927-933
Methods:
We retrospectively reviewed the medical records of 198 women aged 40–70 years who underwent mass screening for osteoporosis at our hospital between 2016 and 2019. The BMD values and the following data were collected: age, body mass index, fracture history, lower back pain, height loss, kyphosis, history of fragility fracture, family history of vertebral or hip fracture, and menopause. The reliability of each data point for the young adult mean <80% was calculated using discriminant analysis. Variables with large weight coefficients were selected and scored. This scoring tool was examined, and a cutoff score for predicting the young adult mean <80% was determined.
Results:
Sixty-four participants (32.3%) had a young adult mean <80%. According to the weight coefficients, the following five variables were scored as follows: age ≥60 years 3 points, body mass index <22 kg/m2 3 points, lower back pain 1 point, height loss (cm) 1 point, and menopause 1 point. The area under the receiver operating characteristic curve was 0.738 (95% confidence interval, 0.669–0.807). At cutoff scores of ≥5 and <5, the sensitivity was 82.8%, with specificity of 52.0%.
Conclusions
The scoring tool performed well for predicting young adult mean <80% among perimenopausal and postmenopausal women in Japan. This tool may be useful to screen for low BMD.