1.Electroretinography recordings using a light emitting diode active corneal electrode in healthy beagle dogs.
Yoshiki ITOH ; Seiya MAEHARA ; Norihiko ITOH ; Kazuto YAMASHITA ; Yasuharu IZUMISAWA
Journal of Veterinary Science 2013;14(1):77-84
Electroretinography (ERG) is a well-established diagnostic procedure for objectively evaluating retinal function. In this study, ERG in beagle dogs, which are a popular experimental animal, was performed to determine the normal range of ERG variables and assess differences between the left and right eyes. ERG findings including rod, combined rod-cone, single-flash cone, and 30-Hz flicker responses were recorded with an LED-electrode in 43 sedated beagle dogs. The subjects were divided into young (< 1 year old), adult (1~5 years old), and senile animals (> or = 6 years old). Normal ERG ranges were obtained. Significant differences in b-wave amplitude along with b/a ratio of the combined rod-cone response were found between the young and adult animals as well as young and senile dogs. No significant differences were observed between the left and right eyes. ERG variables in beagle dogs differed by age due to age-related retinal changes. Thus, we propose that normal ERG ranges should be determined according to age in each clinic and laboratory using its own equipment because each institution usually has different systems or protocols for ERG testing.
Aging
;
Animals
;
Dogs/*anatomy & histology
;
Electrodes/veterinary
;
Electroretinography/methods/*veterinary
;
Female
;
Male
2.Feasibility of Newly Developed Endoscopic Ultrasound with Zone Sonography Technology for Diagnosis of Pancreatic Diseases.
Yoshiki HIROOKA ; Akihiro ITOH ; Hiroki KAWASHIMA ; Eizaburo OHNO ; Yuya ITOH ; Yosuke NAKAMURA ; Takeshi HIRAMATSU ; Hiroyuki SUGIMOTO ; Hajime SUMI ; Daijiro HAYASHI ; Naoki OHMIYA ; Ryoji MIYAHARA ; Masanao NAKAMURA ; Kohei FUNASAKA ; Masatoshi ISHIGAMI ; Yoshiaki KATANO ; Hidemi GOTO
Gut and Liver 2013;7(4):486-491
BACKGROUND/AIMS: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography(TM) technology (ZST; Fujifilm Corp.). METHODS: Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. RESULTS: In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49+/-0.50, 3.65+/-0.48, respectively. After AASS, A and B scored 4.36+/-0.48 and 4.40+/-0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. CONCLUSIONS: EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.
Endoscopes
;
Endosonography
;
Humans
;
Judgment
;
Mucins
;
Pancreatic Diseases