6.Clinical Validation of the Unparalleled Sensitivity of the Novel Allele-Discriminating Priming System Technology–Based EGFR Mutation Assay in Patients with Operable Non–Small Cell Lung Cancer
Il-Hyun PARK ; Dae-Soon SON ; Yoon-La CHOI ; Ji-Hyeon CHOI ; Ji-Eun PARK ; Yeong Jeong JEON ; Minseob CHO ; Hong Kwan KIM ; Yong Soo CHOI ; Young Mog SHIM ; Jung Hee KANG ; Suzy PARK ; Jinseon LEE ; Sung-Hyun KIM ; Byung-Chul LEE ; Jhingook KIM
Cancer Research and Treatment 2024;56(1):81-91
Purpose:
Recently, we developed allele-discriminating priming system (ADPS) technology. This method increases the sensitivity of conventional quantitative polymerase chain reaction up to 100 folds, with limit of detection, 0.01%, with reinforced specificity. This prospective study aimed to develop and validate the accuracy of ADPS epidermal growth factor receptor (EGFR) Mutation Test Kit using clinical specimens.
Materials and Methods:
In total 189 formalin-fixed paraffin-embedded tumor tissues resected from patients with non–small cell lung cancer were used to perform a comparative evaluation of the ADPS EGFR Mutation Test Kit versus the cobas EGFR Mutation Test v2, which is the current gold standard. When the two methods had inconsistent results, next-generation sequencing–based CancerSCAN was utilized as a referee.
Results:
The overall agreement of the two methods was 97.4% (93.9%-99.1%); the positive percent agreement, 95.0% (88.7%-98.4%); and the negative percent agreement, 100.0% (95.9%-100.0%). EGFR mutations were detected at a frequency of 50.3% using the ADPS EGFR Mutation Test Kit and 52.9% using the cobas EGFR Mutation Test v2. There were 10 discrepant mutation calls between the two methods. CancerSCAN reproduced eight ADPS results. In two cases, mutant allele fraction was ultra-low at 0.02% and 0.06%, which are significantly below the limit of detection of the cobas assay and CancerSCAN. Based on the EGFR genotyping by ADPS, the treatment options could be switched in five patients.
Conclusion
The highly sensitive and specific ADPS EGFR Mutation Test Kit would be useful in detecting the patients who have lung cancer with EGFR mutation, and can benefit from the EGFR targeted therapy.
7.Study Design and Protocol for a Randomized Controlled Trial to Assess Long-Term Efficacy and Safety of a Triple Combination of Ezetimibe, Fenofibrate, and Moderate-Intensity Statin in Patients with Type 2 Diabetes and Modifiable Cardiovascular Risk Factors (ENSEMBLE)
Nam Hoon KIM ; Juneyoung LEE ; Suk CHON ; Jae Myung YU ; In-Kyung JEONG ; Soo LIM ; Won Jun KIM ; Keeho SONG ; Ho Chan CHO ; Hea Min YU ; Kyoung-Ah KIM ; Sang Soo KIM ; Soon Hee LEE ; Chong Hwa KIM ; Soo Heon KWAK ; Yong‐ho LEE ; Choon Hee CHUNG ; Sihoon LEE ; Heung Yong JIN ; Jae Hyuk LEE ; Gwanpyo KOH ; Sang-Yong KIM ; Jaetaek KIM ; Ju Hee LEE ; Tae Nyun KIM ; Hyun Jeong JEON ; Ji Hyun LEE ; Jae-Han JEON ; Hye Jin YOO ; Hee Kyung KIM ; Hyeong-Kyu PARK ; Il Seong NAM-GOONG ; Seongbin HONG ; Chul Woo AHN ; Ji Hee YU ; Jong Heon PARK ; Keun-Gyu PARK ; Chan Ho PARK ; Kyong Hye JOUNG ; Ohk-Hyun RYU ; Keun Yong PARK ; Eun-Gyoung HONG ; Bong-Soo CHA ; Kyu Chang WON ; Yoon-Sok CHUNG ; Sin Gon KIM
Endocrinology and Metabolism 2024;39(5):722-731
Background:
Atherogenic dyslipidemia, which is frequently associated with type 2 diabetes (T2D) and insulin resistance, contributes to the development of vascular complications. Statin therapy is the primary approach to dyslipidemia management in T2D, however, the role of non-statin therapy remains unclear. Ezetimibe reduces cholesterol burden by inhibiting intestinal cholesterol absorption. Fibrates lower triglyceride levels and increase high-density lipoprotein cholesterol (HDL-C) levels via peroxisome proliferator- activated receptor alpha agonism. Therefore, when combined, these drugs effectively lower non-HDL-C levels. Despite this, few clinical trials have specifically targeted non-HDL-C, and the efficacy of triple combination therapies, including statins, ezetimibe, and fibrates, has yet to be determined.
Methods:
This is a multicenter, prospective, randomized, open-label, active-comparator controlled trial involving 3,958 eligible participants with T2D, cardiovascular risk factors, and elevated non-HDL-C (≥100 mg/dL). Participants, already on moderate-intensity statins, will be randomly assigned to either Ezefeno (ezetimibe/fenofibrate) addition or statin dose-escalation. The primary end point is the development of a composite of major adverse cardiovascular and diabetic microvascular events over 48 months.
Conclusion
This trial aims to assess whether combining statins, ezetimibe, and fenofibrate is as effective as, or possibly superior to, statin monotherapy intensification in lowering cardiovascular and microvascular disease risk for patients with T2D. This could propose a novel therapeutic approach for managing dyslipidemia in T2D.
8.A Novel Retractable Robotic Device for Colorectal Endoscopic Submucosal Dissection
Sang Hyun KIM ; Chanwoo KIM ; Bora KEUM ; Junghyun IM ; Seonghyeon WON ; Byung Gon KIM ; Kyungnam KIM ; Taebin KWON ; Daehie HONG ; Han Jo JEON ; Hyuk Soon CHOI ; Eun Sun KIM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Joo Ha HWANG
Gut and Liver 2024;18(4):377-385
Background/Aims:
Appropriate tissue tension and clear visibility of the dissection area using traction are essential for effective and safe endoscopic submucosal dissection (ESD). In this study, we developed a retractable robot-assisted traction device and evaluated its performance in colorectal ESD.
Methods:
An experienced endoscopist performed ESD 18 times on an ex vivo porcine colon using the robot and 18 times using the conventional method. The outcome measures were procedure time, dissection speed, procedure-related adverse events, and blind dissection rate.
Results:
Thirty-six colonic lesions were resected from ex vivo porcine colon samples. The total procedure time was significantly shorter in robot-assisted ESD (RESD) than in conventional ESD (CESD) (20.1±4.1 minutes vs 34.3±8.3 minutes, p<0.05). The submucosal dissection speed was significantly faster in the RESD group than in the CESD group (36.8±9.2 mm 2 /min vs 18.1±4.7 mm 2 /min, p<0.05). The blind dissection rate was also significantly lower in the RESD group (12.8%±3.4% vs 35.1%±3.9%, p<0.05). In an in vivo porcine feasibility study, the robotic device was attached to a colonoscope and successfully inserted into the proximal colon without damaging the colonic wall, and ESD was successfully performed.
Conclusions
The dissection speed and safety profile improved significantly with the retractable RESD. Thus, our robotic device has the potential to provide simple, effective, and safe multidirectional traction during colonic ESD.
9.Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease
Hye Jeon HWANG ; Hyunjong KIM ; Joon Beom SEO ; Jong Chul YE ; Gyutaek OH ; Sang Min LEE ; Ryoungwoo JANG ; Jihye YUN ; Namkug KIM ; Hee Jun PARK ; Ho Yun LEE ; Soon Ho YOON ; Kyung Eun SHIN ; Jae Wook LEE ; Woocheol KWON ; Joo Sung SUN ; Seulgi YOU ; Myung Hee CHUNG ; Bo Mi GIL ; Jae-Kwang LIM ; Youkyung LEE ; Su Jin HONG ; Yo Won CHOI
Korean Journal of Radiology 2023;24(8):807-820
Objective:
To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software.
Materials and Methods:
This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1–7 according to acquisition conditions. CT images in groups 2–7 were converted into the target CT sty le (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system.
Results:
Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2–7 improved after CT conversion (original vs. converted: 0.63vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists’ scores were significantly higher (P < 0.001) and less variable on converted CT.
Conclusion
CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.
10.Epidemiologic and Clinical Outcomes of Pediatric Renal Tumors in Korea: A Retrospective Analysis of The Korean Pediatric Hematology and Oncology Group (KPHOG) Data
Kyung-Nam KOH ; Jung Woo HAN ; Hyoung Soo CHOI ; Hyoung Jin KANG ; Ji Won LEE ; Keon Hee YOO ; Ki Woong SUNG ; Hong Hoe KOO ; Kyung Taek HONG ; Jung Yoon CHOI ; Sung Han KANG ; Hyery KIM ; Ho Joon IM ; Seung Min HAHN ; Chuhl Joo LYU ; Hee-Jo BAEK ; Hoon KOOK ; Kyung Mi PARK ; Eu Jeen YANG ; Young Tak LIM ; Seongkoo KIM ; Jae Wook LEE ; Nack-Gyun CHUNG ; Bin CHO ; Meerim PARK ; Hyeon Jin PARK ; Byung-Kiu PARK ; Jun Ah LEE ; Jun Eun PARK ; Soon Ki KIM ; Ji Yoon KIM ; Hyo Sun KIM ; Youngeun MA ; Kyung Duk PARK ; Sang Kyu PARK ; Eun Sil PARK ; Ye Jee SHIM ; Eun Sun YOO ; Kyung Ha RYU ; Jae Won YOO ; Yeon Jung LIM ; Hoi Soo YOON ; Mee Jeong LEE ; Jae Min LEE ; In-Sang JEON ; Hye Lim JUNG ; Hee Won CHUEH ; Seunghyun WON ;
Cancer Research and Treatment 2023;55(1):279-290
Purpose:
Renal tumors account for approximately 7% of all childhood cancers. These include Wilms tumor (WT), clear cell sarcoma of the kidney (CCSK), malignant rhabdoid tumor of the kidney (MRTK), renal cell carcinoma (RCC), congenital mesoblastic nephroma (CMN) and other rare tumors. We investigated the epidemiology of pediatric renal tumors in Korea.
Materials and Methods:
From January 2001 to December 2015, data of pediatric patients (0–18 years) newly-diagnosed with renal tumors at 26 hospitals were retrospectively analyzed.
Results:
Among 439 patients (male, 240), the most common tumor was WT (n=342, 77.9%), followed by RCC (n=36, 8.2%), CCSK (n=24, 5.5%), MRTK (n=16, 3.6%), CMN (n=12, 2.7%), and others (n=9, 2.1%). Median age at diagnosis was 27.1 months (range 0-225.5) and median follow-up duration was 88.5 months (range 0-211.6). Overall, 32 patients died, of whom 17, 11, 1, and 3 died of relapse, progressive disease, second malignant neoplasm, and treatment-related mortality. Five-year overall survival and event free survival were 97.2% and 84.8% in WT, 90.6% and 82.1% in RCC, 81.1% and 63.6% in CCSK, 60.3% and 56.2% in MRTK, and 100% and 91.7% in CMN, respectively (p < 0.001).
Conclusion
The pediatric renal tumor types in Korea are similar to those previously reported in other countries. WT accounted for a large proportion and survival was excellent. Non-Wilms renal tumors included a variety of tumors and showed inferior outcome, especially MRTK. Further efforts are necessary to optimize the treatment and analyze the genetic characteristics of pediatric renal tumors in Korea.

Result Analysis
Print
Save
E-mail