1.Regulatory effects of glucocorticoids on the local renin-angiotensin system in osteoblasts
Yongtao ZHANG ; Chunsheng WANG ; Wenchen JI ; Qichun SONG ; Kunzheng WANG ; Ruiyu LIU
Journal of Xi'an Jiaotong University(Medical Sciences) 2014;(3):324-328
Objective To investigate the regulatory effects of glucocorticoids on the local renin-angiotensin system in osteoblasts by using MC3T3-E1 cells.Methods Cellular immune histochemistry was carried out to observe the renin-angiotensin system in osteoblasts.And then after 12-hour culture in serum-free solution,MC3T3-E1 cells were divided into four groups:control,dexamethasone (DXM),dexamethasone + mifepristone (DXM+MIF)and mifepristone (MIF).Components of the renin-angiotensin system including angiotensin type 1 receptor (AT1R),angiotensin type 2 receptor (AT2R)and angiotensin converting enzyme (ACE)in osteoblasts were detected at the mRNA and protein levels using Western blot and PCR.The activity of ACE was also measured after 36-hour intervention.Results The results of immunohistochemistry showed that AT1R,AT2R and ACE were all expressed in osteoblasts.The activity of ACE increased obviously after dexamethasone intervention compared with that in the control group,which was blocked by mifepristone.The mRNA levels of AT1R,AT2R and ACE were increased by dexamethasone compared with those in the control group,which was inhibited by mifepristone.The protein levels of AT1R,AT2R and ACE were enhanced by dexamethasone compared with those in the control group, which was blocked when the cells were co-intervened with mifepristone.However,ACE activity and the mRNA and protein levels of AT1R,AT2R and ACE did not change when the cells were intervened with mifepristone alone (P>0.05).Conclusion The local renin-angiotensin system in osteoblasts is activated by dexamethasone through glucocorticoid receptors on osteoblasts,which may be one of the pathogenesis of glucocorticoid-induced osteoporosis.
2.Application of timely regional vascular occlusion in primary liver cancer resection
Le JI ; Yonghong ZI ; Yongtao GAO ; Too LIU ; Lang BAI
International Journal of Surgery 2018;45(6):386-391
Objective To study the application effects of timely regional vascular occlusion in primary liver cancer(PLC) surgery. Methods Eighty-eight patients with PLC who underwent surgery in the Department of General Surgery of Yan'an University Affiliated Hospital from January 2014 to December 2016 were selected for prospective study, and they were divided into the experimental group and the control group by the random number table method, 44 cases of each group. In the experimental group, the blood supply was blocked with timely regional vascular occlusion while in the control group, the blood supply was blocked with half hepatic vascular occlusion. The occurrence of postoperative complications, and surgical indexes(surgical time, intraoperative blood loss, the time of hepatic portal occlusion, blood transfusion volume, abdominal drainage volume and hospital stay), levels of alanine aminotransferase, albumin and total bilirubin, levels of CD3+, CD4+, CD8+ and CD4 + /CD8 +, effective rate, control rate, and clinical efficacy were compared between the two groups. Measurement data with normal distribution were represented as (x) ± s and analyzed using the independent-sample t test between the two groups; within the groups, paired t-tests were used. Comparison of count data were represented as n(% ), and analyzed using the chi-square test. Results The intraoperative blood loss, time of hepatic portal occlusion, blood transfusion volume and hospital stay of the experimental group were(331. 48 ±30.65) ml, (14.78土2.27) min, (132.61 ±13.87) ml, (9.29土1.19) d, and the control group were (500.61 ±50.62) ml, (23.96±2.89) min, (305.76 ± 30.64) ml, (12.10 ± 1.22) d, with statistically significant differences in above indexes between the two groups(all P< 0.05). The operation time and abdominal drainage volume in the experimental group were(146.86 ± 15.87) min and(321.77 ±33.65) ml respectively, while those in the control group were (143.07土15.35) min and(335.18 ±33.82) ml respectively, there was no significant difference between the two groups(P> 0.05 ). After surgery, the levels of alanine aminotransferase, total bilirubin and albumin of the experimental group were(54.86 ±5.61) U/L, (20.65 ± 2.32) U/L, (41.95土4.32) ng/ml, and the control group were(120.75 ± 13.03) U/L, (35.42+3.21) U/L, (70.25 ±7.45) ng/ml, with statistically significant differences in above indexes between the two groups(all P <0.05). After surg;ery, the levels of CD3 +, CD4+, CD8 + and CD4 + /CD8 + of the experimental group were 0.63 ±0.16, 0.52 ± 0.11, 0.20 ±0.04, 1.70 ±0.17 and the control group were 0.56 ±0.14, 0.45±0.12, 0.26 ± 0.05, 1.46土0.22, with statistically significant differences in above indexes between the two groups (all P< 0.05 ). There were no differences between the experimental group and the controlg roup in the response rate and the control rate(75.00% vs.79.55%; 88. 64% vs.90.91% ) (P>0.05). Conclusions The application of timely regional vascular occlusion in PLC surgery can reduce the intraoperative blood loss, the time of hepatic portal occlusion, blood transfusion volume and hospital stay, improve the immune level and liver function. And there is no difference in response rate and control rate compared with half hepatic vascular occlusion, therefore it is worthy of clinical application.
3.Design of Multifunctional Automated External Defibrillator Based on STM32.
Kewu WANG ; Shengxiang XIAO ; Yongtao JI ; Yuqiu FANG
Chinese Journal of Medical Instrumentation 2018;42(1):22-26
This paper presents a design of multifunctional portable automated external defibrillator based on STM32F103VC SCM. The defibrillator mainly realizes the defibrillation and ECG analysis function, and according to the clinical actual need, increases information storage and transmission function, query of local records, the function of synchronous LCD display and voice prompt in the defibrillation process. The device uses the defibrillating electrodes to measure body resistance, ECG and so on. We detailedly researched and achieved the discharge module of biphasic defibrillation apparatus based on the damping of two order discharge circuit, and finished the real-time LCD display and voice prompt modules of defibrillation information based on the control of PIC24FJ256DA210 chip.
Automation
;
Defibrillators
;
Electric Countershock
;
Electrodes
;
Equipment Design