1.Nosocomial Infection Problems Found in Terminal Patients Records Inspection
Min HE ; Li ZHANG ; Yongsheng QIN
Chinese Journal of Nosocomiology 2009;0(21):-
OBJECTIVE To check the defects of nosocomial infections reports,recording of the patient′s history,and antibiotics usage,so as to improve hospital management and reduce nosocomial infection.METHODS Patient′s records from Jan 1,2008 to Dec 31,2008 were reviewed to find out the defects and feedback to the physicians.RESULTS Some problems of 5995 cases were checked out and corrected,some suggestions were made.CONCLUSIONS Checking the patient′s records may supplement the defects of prospective monitor,direct the antibiotics therapy,and monitor occurrence of drug resistance.
2.Exploitation and Application of Medical Service Management Information System for Field Medical Point
Qicai HE ; Xiaoyun LI ; Yongsheng WU ; Xizhou WANG ; Hao HU
Chinese Medical Equipment Journal 2004;0(08):-
Objective To strengthen the capability of emergent supply in field medical point.Methods The common application program was designed by using PowerBuilder.The database program was Oracle.Results The assistant conduction and management of information were realized including the information of staff,war materials,equipment,wounded soldiers in the field medicine.Conclusion Information management system in field hospital can rapidly and accurately provide all kinds of information for users.It can be extensively applied in all levels of field hospitals.
3.The feasibility of direct applying MRI to treatment planning system of radiotherapy for intra-cranial tumor
Liming XU ; Zhaoxi ZHANG ; Yongsheng LIU ; Xiaohong WANG ; Zhengzhong HE
Chinese Journal of Radiation Oncology 1992;0(04):-
Objective Objective To study the feasibility of direct applying MRI to TPS by measuring the geometric distortion of MRI. Methods Phantom 1 was made by marking radical arrangement of fat pipelines every 15? in foam phantom and Phantom 2 by net arrangement at every 2.7?cm. Coronal and transverse scan parallel with the radial and net fat pipeline in the phantom was performed at sequence of cranial FSE T2WI by Marconi 1.5T superconduct MRI machine. Geometric distortion in 5 different fields of view (FOV) was calculated by measuring the absolute borderline error of direct scan and coronal digital reconstructed radiograph (DRR). Results When FOV was equal or smaller than 11.0?cm?11.0?cm, 22.0?cm?22.0?cm and 27.5?cm?27.5?cm, the geometric distortion was 0.0, 1.1 and 1.4?mm of direct scanning MRI and 1.0,1.4 and 2.0?mm of coronal DRR. Conclusion When the magnetic field of MR is high and the tissue shows uniform density, MRI can be applied on TPS directly.
4.Diagnosis and treatment of traumatic diaphragmatic hernia ( a report of 23 cases)
Qi HE ; Wei WANG ; Yu WANG ; Yongsheng WANG
Chinese Journal of General Surgery 1997;0(06):-
Objective To study the early diagnosis and treatment of traumatic diaphragmatic hernia(TDH). Methods Retrospective analysis of the clinical data of 23 cases of TDH was made. Result 12 cases(51%) were preoperatively diagnosed,10 cases(43.5%) misdiagnosed,1 case was misdiagnosed during exploration laporatomy. 20 cases(86.9%) were cured and 3(13.1%) died. 1 case died of toxic shock because of misdignosis resulted in intestinal strangulation. Conclusions Increasing knowledge, dynamic observation of the disease and X-ray, promptly exploration can reduce the rate of misdiagnosis of TDH. With early diagnosis and treatment, most cases of TDH can be cured. The main cause of the death results from delayed diagnosis and treatment, and not related to TDH itself.
5.Experimental Study of Curative Effect of Compound Anmei Oral Liquid on Insomnia
Jiancheng HE ; Binghong PU ; Yongqi LIU ; Yingshou LI ; Yongsheng LI ;
Chinese Traditional Patent Medicine 1992;0(01):-
Objective:To sutdy effects of Compound Anmei Oral Liquid on spontaneous activity, sleep, convulsion of experimental mice.Methods: The effects of oral liquid were observed in the spontaneous activity and the sleep time of mice when they were given Nembuta in a threshold dose or a subliminal dose and its anti convulsant effect to investigate the actions of oral liquid.Results: This oral liquid could inhibit the spontaneous activity and cooperate with pentobarbital sodium to effect the sleep time of mice. It also resist convulsion. Conclusions: Compound Anmei Oral Liquid has obvious sedation, hypnosis and anti convulsant effect.
6.Study on quality standard for Qiankun Liquid
Yongsheng WEN ; Shiyu ZHOU ; Ling LI ; Yuxin HE ;
Chinese Traditional Patent Medicine 1992;0(06):-
Objective: To establish the quality standard for Qiankun Liquid.Methods: Fructus Lycii、Fructus Cnidii、Radix Ginseng in Qiankun Liquid were identified by TLC, and the content of icariin was determined by HPLC.Results: Fructus Lycii、Fructus Cnidii、Radix Ginseng could be identified by TLC. Icariin showed a good linear relationship at a range of 0.126~1.008?g, r =0.9999. Conclusion: The method is accurate and can be used for the quality control of Qiankun Liquid.
7.Dual-source CT coronary angiography in patients with medium and low heart rate: imaging quality and radiation doses at a low tube voltage
Yongsheng HU ; Xinhua HE ; Xuan FU ; Ziyong WANG ; Hui WANG ; Hao CHEN ; Changjun FEI ; Jinwu WANG
Chinese Journal of Radiology 2011;45(3):279-283
Objective To evaluate the imaging quality and radiation doses of dual-source computed tomography (DSCT) coronary angiography at a low tube voltage in patients with medium and low heart rate.Methods Eighty-five patients[heart rate (HR) < 91 beats per minute (bpm); body mass index (BMI) 17. 51-30. 00 kg/m2]suspected of coronary artery disease received retrospectively ECG-gating coronary angiography with dual-source CT scanner (Somatom Definition, Siemens) at a tube voltage of 100 kVp. For all patients, no beta-blocker was used before CT scan. According to the HR, the patients were divided into three groups: Group A, HR ≤ 59 bpm, n = 27; Group B, HR 60-69 bpm, n = 29; Group C,HR ≥70 bpm, n = 29. All images were transferred to a workstation for postprocessing. The best R-R interval reconstruction images of all groups were evaluated. The value of pitch, CT volume dosage index (CTDIvol), dose length product (DLP)and effective dose (ED)were recorded. The pitch, the score of imaging quality of coronary artery segments and the radiation dose were compared with one-way ANOVA. The influence of HR on image quality and radiation doses of coronary artery was analyzed. Results The value of pitch in Group A, Group B and Group C was 0. 241 ± 0. 025, 0. 286 ± 0. 034 and 0. 335 ± 0. 036,respectively. The mean score of imaging quality of coronary artery segments in Group A, Group B and Group C was 4. 78 ± 0. 26, 4. 66 ± 0. 56 and 4. 70 ± 0. 46, respectively. The value of CTDIvol in Group A,Group B and Group C was (18.06 ±5. 16), (19. 62 ±7. 15) and (17. 50 ±7. 13) mGy, respectively. The value of ED in group A, Group B and Group C was (4.23 ± 1.76), (4.59 ± 1.75) and (4.12 ±1.39) mSv, respectively. There was statistical difference in value of pitch among the three groups (F =60. 00, P= 0. 00). There were no statistical difference in score of imaging quality, CTDIvol and value of ED among the three groups (F = 0. 53, P = 0. 59; F = 0. 83, P = 0. 44 ; F = 0. 86, P = 0. 43). Conclusion Medium and low HR have little influences on image quality of dual-source CT coronary angiography at a low tube voltage. When the auto ECG-gating is selected, there is little influence on radiation dosage as well.
8.Study of pulmonary artery monitoring for intracranial and cervical artery angiography with dual energy CT
Xinhua HE ; Yongsheng HU ; Ziyong WANG ; Yue YANG ; Xuan FU ; Changjun FEI ; Yan FAN ; Jingwu WANG
Chinese Journal of Radiology 2012;(12):1126-1131
Objective To explore the application value of pulmonary artery monitoring program for intracranial and cervical artery angiography with dual-energy CT.Methods Sixty patients performed intracranial and cervical artery angiography with dual-energy CT were divided into two groups according to the random number table.Group A (optimization group,30 patients):the monitoring points were located in the main pulmonary artery,with threshold 150 HU,trigger delay time 8-9 s,pitch 0.9,and the iohexol (350 mg I/ml) 60-65 ml.Group B (conventional group,30 patients):the monitoring points were located in aortic arch,with threshold 100 HU,trigger delay time 5 s,and the iohexol (350 mg I/ml)60-70 ml.Patients with the body weight less than 75 kg were injected with the flow rate of 4.0 ml/s,and those weight greater than 75 kg or with body mass index (BMI) greater than 27 kg/m2 were 4.5 ml/s,following 40 ml saline solution with the same flow rate respectively.All images were transferred to Siemens Syngo workstation for further processing and analysis.The attenuation values were measured on axial images in the common carotid artery,internal and external carotid artery,vertebral and basilar artery,the horizontal segment of the middle cerebral artery,the subclavian vein of injection side,the proximal,middle and distal segment of jugular vein,the straight sinus and the superior sagittal sinus.Two experienced observers blinded independently evaluated the image quality of CTA,the impact of contrast material residues artifacts of subclavian vein of injected side and the affect of venous return factors on arterial image display.Images of volume rendering technique(VR),the maximum intensity projection (MIP),and curved planar reformation (CPR) were reconstructed using dual energy bone removal and Inspace and 3D software.The mean intraluminal attenuation of contrast material (HU),the volume of contrast material and the mean image quality scores were compared with t test between the two groups.Chi-square test was used to compare of image contrast agents residual artifacts,the absence segments of the root of the neck artery,and the degree of the jugular vein return in two groups.Results The mean CT values were 372-414 HU for each segment of artery showing no significant differences between two groups (P > 0.05).In group A,the CT values of the jugular vein in proximal,middle,distal segment of the two sides were (95 ± 36),(95 ± 36),(131 ±58),(133 ± 57),(174 ± 68),and (180 ± 66) HU respectively.In group B,CT values were (135 ± 58),(137 ±59),(170 ±58),(181 ±58),(218 ±62),and (224 ±68) HU.The CT value of jugular venous in group A was significantly lower than that in group B (t =-3.30--2.54,P < 0.05).Case numbers of contrast agent residual artifacts of injection side subclavian vein and the absence segments of root of the neck artery at the beginning in group A (5,11) were less than that in group B (12,24) (x2 =4.02,5.65,P <0.05).The degree of the jugular vein return in group A were lesser severely than that in group B (x2 =6.79,6.37,P <0.05).Below the level of carotid artery bifurcation:slight 5 patients,severe 1 patient in group A vs.slight 15 patients,severe 9 patients in group B.Above the level of carotid artery bifurcation:slight 9 patients,severe 6 patients in group A vs.slight 12 patients,severe 17 patients in group B.Image quality scores of group A (3.84 ± 0.40) was higher than that of group B (3.64 ± 0.63) (t =4.26,P <0.05).Conclusions Pulmonary Artery Monitoring combines with 60-65 ml contrast material optimization scheme for intracranial and cervical artery angiography with dual energy CT can significantly reduce the degree of jugular venous return and contrast material residues artifacts of subclavian vein of injected side.This technique is helpful to improve the work efficiency and image quality.
9.Partial safety of Ad-HIF-1α-Trip gene transfection on a rabbit model of acute hind-limb ischemia
Wenkai HE ; Mingyan LI ; Yongsheng CUI ; Jianwei CHEN ; Yuegang WANG ; Dongdong CHEN ; Pingsheng WU
The Journal of Practical Medicine 2014;(13):2028-2030
Objective To investigate the partial safety of the recombinant adenovirus containing the triple-point mutants HIF-1αgene (Ad-HIF-1α-Trip)transfection in a rabbit model of hind limb ischemia. Methods After ligation of left femoral artery, 22 New Zealand whites rabbits were randomly divided into 3 groups: saline group(n=6), Ad-Null group(n=6) and Ad-HIF-1α-Trip group(n=10). After operation, saline, Ad-Null and Ad-HIF-1αwere injected intramuscularly respectively. The expression of transferred HIF-1αat mRNA level in the ischemic skeletal muscle and other important organs were detected by Real-time PCR 10 days after gene transfection. The body temperature, weight, blood, liver and renal function, as well as the myocardial enzymes were detected before operation, and on the 3th, 7th, 14th and 28th day after gene transfection, so that pathological changes could be observed. Results On the 10th day after gene transfection, obvious expressions of HIF-1αat mRNA level in the ischemic limb were found, but no expression in other important organs was detected in Ad-HIF-1α-Trip group. The blood routine, liver and renal function were all in the normal range (P > 0.05). No abnormalities were found in heart, liver, kidney, and lung HE transfection in Ad-HIF-1α-Trip group. Conclusion Single intramuscular injection of Ad-HIF-1α-Trip can be expressed obviously in the ischemic limb without detected damage of liver , cardiac and kidney.
10.The value of CT in 125I seed implantation in the treatment of tumors
Yongcui HUANG ; Bin GAO ; Kewu HE ; Yongsheng HU ; Huimin CHAO ; Jie ZHENG ; Xiyun GU
Chinese Journal of Primary Medicine and Pharmacy 2010;17(13):1740-1742,后插2
Objective To evaluate the role and technical advantages of CT in 125Ⅰseed implantation in the treatment of tumors. Methods CT-guided 125Ⅰ seed implantation in 45 cases of cancer patients treated 57 times in 51 lesions,CT were used to evaluate the progress of lesions after 125Ⅰ seed implantation 1,2,6 months. Results All procedures were once successful and the total effective rate was 74.5% without any serious complications. Fifty CT examinations immediately after implantation showed satisfactorily seeds distribution but seven cases less satisfactorily that include particles overlap,the location is too close to the lesion edge,the larger the radiation cold spots,etc. Follow-up CT reexamination in 1,2 and 6 months demonstrated that CT examinations showed satisfactorily seeds distribution but accurate seeds number,which could be solved by combined with MPR images and the positioning piece. Conclusions CT-guided 125Ⅰ seed implantation treatment of tumors was a safe,reliable and effective minimally invasive treatment. CT in the preoperative treatment of seed implants planning,precise intraoperative guidance,quality assurance and efficacy of postoperative assessment had a greater role and application advantages.