1.Short-term efficacy and safety of Donafenib as postoperative adjuvant therapy for patients with high risk of recurrence after radical resection of hepatocellular carcinoma: a multicenter retrospective study
Jianhua RAO ; Xinhua ZHU ; Hongwei ZHANG ; Shaochuang WANG ; Xin WEI ; Yonghua XU ; Long ZHANG ; Zhengfeng XUAN ; Yongquan CHI ; Feng ZHANG ; Xuehao WANG ; Ling LYU ; Feng CHENG
Chinese Journal of Digestive Surgery 2023;22(12):1433-1443
Objective:To investigate the short-term efficacy and safety of Donafenib as postoperative adjuvant therapy for patients with high risk of recurrence after radical resection of hepatocellular carcinoma (HCC).Methods:The propensity score matching (PSM) and retrospective cohort study was conducted. The clinicopathological data of 157 HCC patients with high risk of recurrence after radical resection who were admitted to 6 medical centers, including The First Affiliated Hospital of Nanjing Medical University et al, from June 2021 to February 2023 were collected. There were 128 males and 29 females, aged (59±10)years. Of 157 patients, 101 cases undergoing Donafenib as postoperative adjuvant therapy were divided into the the Donafenib group, and 56 cases under-going no systemic postoperative adjuvant therapy were divided into the control group. Observation indicators: (1) PSM and comparison of general data of patients between the two groups after matching; (2) postoperative treatment; (3) follow-up and survival of patients; (4) analysis of risk factors affecting recurrence-free survival of patients. PSM was done based on the principle of optimal perfect matching, with the clamp value of 0.5, and the Donafenib group and the control group were matched at a ratio of 1.25∶1. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was conducted using the t test. Measurement data with skewed distribution were represented as M(range). Count data were described as absolute numbers and/or percentages, and comparison between groups was conducted using the chi-square test. Comparison of ordinal data between groups was conducted using the Kruskal-Wallis H test. The Kaplan-Meier method was used to calculate survival rates and draw survival curves, and the Log-Rank test was used for survival analysis. The COX proportional hazard model was used for univariate and multivariate analyses. Results:(1) PSM and comparison of general data of patients between the two groups after matching. Of 157 patients, 126 cases were successfully matched, including 70 cases in the Donafenib group and 56 cases in the control group, respectively. The elimination of tumor number confounding bias ensured comparability between the two groups after PSM. (2) Postoperative treatment. After PSM, of 70 patients in the Donafenib group, there were 23 cases receiving Donafenib monotherapy, 26 cases combined with transcatheter arterial chemoembolization (TACE), 14 cases combined with immunotherapy, and 7 cases combined with TACE+immunotherapy. Of 56 patients in the control group, there were 37 cases receiving postoperative follow-up alone and 19 cases combined with TACE. (3) Follow-up and survival of patients. All 157 patients were followed up, and the follow-up time of the 101 patients in Donafenib group and the 56 patients in control group were 10.1(range, 6.3-14.6)months and 22.2(range, 15.1-25.5)months, respectively. During the follow-up period, 70 patients in the Donafenib group experienced treatment-related adverse reactions, inclu-ding 8 cases of grade 3 adverse reactions, 23 cases of grade 2 and 39 cases of grade 1 adverse reactions, respectively. After PSM, the postoperative 12-, 18-month recurrence-free survival rates were 83.7%, 83.7% in the 70 patients of Donafenib group and 67.8%, 58.9% in the 56 patients of control group, respectively, showing a significant difference in the postoperative recurrence-free survival time between the two groups ( hazard ratio=0.395, 95% confidence interval as 0.176-0.888, P<0.05). (4) Analysis of risk factors affecting recurrence free survival of patients. Results of multivariate ana-lysis showed that microvascular invasion, vascular thrombus, clinical stage as ⅢA were independent risk factors affecting recurrence-free survival in patients with high risk of recurrence after radical resection of HCC ( hazard ratio=2.181, 2.612, 2.612, 95% confidence interval as 1.028-4.629, 1.128-6.047, 1.128-6.047, P<0.05), Donafenib as postoperative adjuvant therapy was an independent protective factor affecting recurrence-free survival in patients with high risk of recurrence after radical resection of HCC ( hazard ratio=0.457, 95% confidence interval as 0.227-0.920, P<0.05). Results of further analysis showed that after PSM, there were significant differences in the postoperative recurrence-free survival time in patients with different clinical factors, including male, age ≥60 years, tumor diameter >5 cm, positive microvascular invasion, positive hepatitis B virus infection, alpha fetoprotein <200 μg/L, between the Donafenib group and the control group ( hazard ratio=0.283, 0.202, 0.174, 0.345, 0.273, 0.180, 95% confidence interval as 0.114-0.707, 0.044-0.937, 0.038-0.794, 0.128-0.929, 0.091-0.819, 0.052-0.620, P<0.05). Conclusion:Donafenib as postoperative adjuvant therapy can effectively reduce the short-term recurrence rate in patients with high risk of recurrence after radical resection of HCC, with good safety and tolerance.
2.A multicenter study on the establishment and validation of autoverification rules for coagulation tests
Linlin QU ; Jun WU ; Wei WU ; Beili WANG ; Xiangyi LIU ; Hong JIANG ; Xunbei HUANG ; Dagan YANG ; Yongzhe LI ; Yandan DU ; Wei GUO ; Dehua SUN ; Yuming WANG ; Wei MA ; Mingqing ZHU ; Xian WANG ; Hong SUI ; Weiling SHOU ; Qiang LI ; Lin CHI ; Shuang LI ; Xiaolu LIU ; Zhuo WANG ; Jun CAO ; Chunxi BAO ; Yongquan XIA ; Hui CAO ; Beiying AN ; Fuyu GUO ; Houmei FENG ; Yan YAN ; Guangri HUANG ; Wei XU
Chinese Journal of Laboratory Medicine 2020;43(8):802-811
Objective:To establish autoverification rules for coagulation tests in multicenter cooperative units, in order to reduce workload for manual review of suspected results and shorten turnaround time (TAT) of test reports, while ensure the accuracy of results.Methods:A total of 14 394 blood samples were collected from fourteen hospitals during December 2019 to March 2020. These samples included: Rules Establishment Group 11 230 cases, including 1 182 cases for Delta check rules; Rules Validation Group 3 164 cases, including 487cases for Delta check; Clinical Application Trial Group 77 269 cases. Samples were analyzed for coagulation tests using Sysmex CS series automatic coagulation analyzers, and the clinical information, instrument parameters, test results, clinical diagnosis, medication history of anticoagulant and other relative results such as HCT, TG, TBIL, DBIL were summarized; on the basis of historical data, the 2.5 and 97.5 percentile of all data arranged from low to high were initially accumulated; on the basis of clinical suggestions, critical values and specific drug use as well as relative guidelines, autoverification rules and limits were established.The rules were then input into middleware, in which Stage I/Stage II validation was done. Positive coincidence, negative coincidence, false negative, false positive, autoverification pass rate, passing accuracy (coincidence of autoverification and manual verification) were calculated. Autoverification rules underwent trial application in coagulation results reports.Results:(1) The autoverification algorisms involve 33 rules regarding PT/INR, APTT, FBG, D-dimer, FDP,Delta check, reaction curve and sample abnormalities; (2)Autoverification Establishment Group showed autoverification pass rate was 68.42% (7 684/11 230), the false negative rate was 0%(0/11230), coincidence of autoverification and manual verification was 98.51%(11 063/11 230), in which positive coincidence and negative coincidence were respectively 30.09% (3 379/11 230) and 68.42%(7 684/11 230); Autoverification Validation Group showed autoverification pass rate was 60.37%(1 910/3 164), the false negative rate was 0%(0/11 230), coincidence of autoverification and manual verification was 97.79%(3 094/3 164), in which positive coincidence and negative coincidence were respectively 37.42%(1 184/3 164) and 60.37%(1 910/3 164); (3) Trialed implementation of these autoverification rules on 77 269 coagulation samples showed that the average TAT shortened by 8.5 min-83.1 min.Conclusions:This study established 33 autoverification rules in coagulation tests. Validation showedthese rules could ensure test quality while shortening TAT and lighten manual workload.