1.Efficacy of the Digit-in-Noise Test: A Systematic Review and Meta-Analysis
Chanbeom KWAK ; Jae-Hyun SEO ; Yonghee OH ; Woojae HAN
Journal of Audiology & Otology 2022;26(1):10-21
Background and Objectives:
Although the digit-in-noise (DIN) test is simple and quick, little is known about its key factors. This study explored the considerable components of the DIN test through a systematic review and meta-analysis.
Materials and Methods:
After six electronic journal databases were screened, 14 studies were selected. For the meta-analysis, standardized mean difference was used to calculate effect sizes and 95% confidence intervals.
Results:
The overall result of the meta-analysis showed an effect size of 2.224. In a subgroup analysis, the patient’s hearing status was found to have the highest effect size, meaning that the DIN test was significantly sensitive to screen for hearing loss. In terms of the length of the presenting digits, triple digits had lower speech recognition thresholds (SRTs) than single or pairs of digits. Among the types of background noise, speech-spectrum noise provided lower SRTs than multi-talker babbling. Regarding language variance, the DIN test showed better performance in the patient’s native language(s) than in other languages.
Conclusions
When uniformly developed and well validated, the DIN test can be a universal tool for hearing screening.
2.Epidural Granulocytic Sarcoma involving the Thoracic Spine and Sternum in Acute Myelogenous Leukemia.
Dongil KIM ; Doyeun OH ; Sunggon PARK ; Seongwook OH ; Kyeweon KWON ; Yonghee LEE ; Myungseo KANG
Korean Journal of Hematology 1999;34(2):349-352
Granulocytic sarcoma is a localized tumor composed of immature cells of the granulocytic series. Most granulocytic sarcomas occur in the course of acute leukemia and the blast crisis of chronic leukemia. Rarely, however, it may present before leukemia becomes clinically apparent. It may also occur in patients with myeloproliferative disorders. It has been reported that it occurs in 3% to 9% of patients with acute myelogenous leukemia (AML) and the incidence of granulocytic sarcoma is reported to be higher in patients with t (8;21). However, epidural granulocytic sarcoma associated with t (8;21) is very rare. In this report, we describe a patient with AML associated with t (8;21) in whom the cord compression occurred due to epidural granulocytic sarcoma. In addition, this case present infiltration of both pleura by blast cells. She was treated with local irradiation and chemotherapy successfully.
Blast Crisis
;
Drug Therapy
;
Humans
;
Incidence
;
Leukemia
;
Leukemia, Myeloid, Acute*
;
Myeloproliferative Disorders
;
Pleura
;
Sarcoma, Myeloid*
;
Spine*
;
Sternum*
3.Factors Influencing the Korean Version of the Digit-in-Noise Test
Subin KIM ; Chanbeom KWAK ; Woojae HAN ; Jae-Hyun SEO ; Yonghee OH
Journal of Audiology & Otology 2023;27(2):88-96
Background and Objectives:
The digits-in-noise (DIN) test was developed as a simple and time-efficient hearing-in-noise test worldwide. The Korean version of the DIN (K-DIN) test was previously validated for both normal-hearing and hearing-impaired listeners. This study aimed to explore the factors influencing the outcomes of the K-DIN test further by analyzing the threshold (representing detection ability) and slope (representing test difficulty) parameters for the psychometric curve fit.
Subjects and Methods:
In total, 35 young adults with normal hearing participated in the K-DIN test under the following four experimental conditions: 1) background noise (digit-shaped vs. pink noise); 2) gender of the speaker (male vs. female); 3) ear side (right vs. left); and 4) digit presentation levels (55, 65, 75, and 85 dB). The digits were presented using the method of constant stimuli procedure. Participant responses to the stimulus trials were used to fit a psychometric function, and the threshold and slope parameters were estimated according to pre-determined criteria. The accuracy of fit performance was determined using the root-mean-square error calculation.
Results:
The listener’s digit detection ability (threshold) was slightly better with pink noise than with digit-shaped noise, with similar test difficulties (slopes) across the digits. Gender and the tested ear side influenced neither the detection ability nor the task difficulty. Additionally, lower presentation levels (55 and 65 dB) elicited better thresholds than the higher presentation levels (75 and 85 dB); however, the test difficulty varied slightly across the presentation levels.
Conclusions
The K-DIN test can be influenced by stimulus factors. Continued research is warranted to understand the accuracy and reliability of the test better, especially for its use as a promising clinical measure.
4.A Comparison Between the Korean Digits-in-Noise Test and the Korean Speech Perception-in-Noise Test in Normal-Hearing and Hearing-Impaired Listeners
Subin KIM ; Sungwha YOU ; Myoung Eun SOHN ; Woojae HAN ; Jae-Hyun SEO ; Yonghee OH
Journal of Audiology & Otology 2021;25(4):171-177
Background and Objectives:
The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice.
Subjects and Methods:
Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test.
Results:
Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants’ qualitative reports than the K-SPIN test.
Conclusions
In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.
5.Formulation Characteristics of Three Kinds of Elravie(R) Fillers.
Yi Seop SONG ; Yonghee LEE ; Hyeong Mi KIM ; In Pyeong SON ; Bong Youl CHUNG ; Jong oh LEE ; Chae Young LIM ; Kui Young PARK ; Kapsok LI ; Beom Joon KIM
Korean Journal of Dermatology 2014;52(2):100-105
BACKGROUND: Hyaluronic acid (HA) is a mucopolysaccharide that occurs naturally throughout the human body, where it attaches to collagen and elastin to form cartilage, and also helps maintain the strength and flexibility of the cartilage that cushions joints. A decline in HA synthesis may lead to a variety of symptoms, ranging from joint discomfort, to wrinkles. Cross-linked HA is a viscoelastic solid that resists in vivo degradation by hyaluronidase for much longer than endogenous HA, and which is also a key ingredient in various cosmetics. OBJECTIVE: To describe our experience with three kinds of Elravie(R) fillers. METHODS: We obtained images of filler shape using a folliscope. Scanning electron microscopy (SEM) was used to compare particle sizes. Hydrophilic filler is a hydroxyl, and for this reason, we mixed the filler with water. Next, PARKER ink was added to the mixture, and viscosity and elasticity were measured using a rheometer. RESULTS: Among the tested fillers, particle size was largest in the Restylane(R) SubQ. Elravie(R) ultra volume filler was greater in volume than Elravie(R) deep line, and Elravie(R) light fillers. We confirmed Elravie(R) fillers to be hydrophilic. Elravie(R) ultra volume filler was found to have the highest viscosity and elasticity, whilst Elravie(R) light filler had the lowest. CONCLUSION: All three kinds of Elravie(R) fillers were found to be suitable for human cosmetic use.
Cartilage
;
Collagen
;
Elasticity
;
Elastin
;
Human Body
;
Humans
;
Hyaluronic Acid
;
Hyaluronoglucosaminidase
;
Ink
;
Joints
;
Microscopy, Electron, Scanning
;
Particle Size
;
Pliability
;
Viscosity
;
Water