1.Influence of the complexity metrics of the multi-leaf collimator on the γ-pass rate of volumetric modulated arc therapy plans for nasopharyngeal carcinoma
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):309-316
Objective:To investigate the influence of the complexity metrics of the multi-leaf collimator (MLC) on the γ-pass rate of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC).Methods:A total of 60 VMAT plans for NPC were selected to measure the γ-pass rate. The MLC data across all control points (CPs) in each VMAT plan were analyzed to calculate the mean field area (MFA), average leaf gap (ALG), small aperture score (SAS), and their corresponding weighted metrics including MFAW, ALGW, and SASW, considering dose weight (W). Pearson′s bivariate correlation analysis was conducted to examine the correlations between MLC complexity metrics and the γ-pass rate. Moreover, the receiver operating characteristic (ROC) analysis was employed to assess the predictive efficacy of MLC complexity metrics on dose verification result.Results:Under the 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria, the MFA in the 60 VMAT plans exhibited a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.72, P<0.05), and the MFAW was also positively correlated with the γ-pass rate ( r=0.83, 0.81, 0.75, P<0.05). The ALG manifested a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.74, P<0.05), as did the ALGW ( r=0.83, 0.81, 0.77, P<0.05). The SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) displayed negative correlations with the γ-pass rate ( r= -0.86, -0.82, -0.71, -0.84, -0.82, -0.72, -0.79, -0.79, -0.73, -0.30, -0.35, -0.42, P<0.05), whereas the SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) showed positive correlations with the γ-pass rate ( r=0.49, 0.45, 0.33, 0.73, 0.71, 0.59, 0.79, 0.79, 0.76, P<0.05). The outcomes of SASW reveal slightly stronger correlations than those of SAS. In terms of correlations among complexity metrics, a positive correlation was observed between MFA and ALG ( r=0.98, P<0.05). ALG was negatively correlated with SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) ( r= -0.95, -0.94, -0.89, -0.39, P<0.05), and positively correlated with SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) ( r=0.51, 0.77, 0.92, P<0.05). The weighted result mirrored these correlations. The ROC-derived analytical result indicate that MFA, MFAW, ALG, ALGW, SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), SAS(6-40 cm), SASW(0-1 cm), SASW(1-2 cm), SASW(2-3 cm), and SASW(6-40 cm) demonstrated exceptional predictive efficacy for dose verification result [Area under the curve (AUC) > 0.9, P<0.05]. Conclusions:The γ-pass rate of VMAT plans for NPC is strongly correlated with MLC complexity metrics, which demonstrate excellent predictive efficacy for dose verification result. The increased uncertainty in dose calculations and measurements caused by narrow fields generated by the MLC is a significant factor contributing to the reduced γ-pass rate of VMAT plans. This finding is associated with discrepancies in the precision of treatment planning system (TPS) modeling and the accuracy of dose verification tools, providing a reference for similar challenges.
2.A comparative study of radiotherapy using three distinct radiotherapy techniques following immediate breast reconstruction for breast cancer
Xiantao HE ; Zhuohua XU ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):317-324
Objective:To investigate the differences in dosimetric parameters for target volumes and organs at risk (OARs), radiation doses to reconstructed tissues, and beam-on time in radiotherapy among helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (F_IMRT) following immediate breast reconstruction for breast cancer, thereby providing a reference for the selection of clinical radiotherapy techniques.Methods:This study retrospectively investigated 15 breast cancer patients who underwent radiotherapy following modified radical mastectomy and immediate breast reconstruction at the Liuzhou Worker′s Hospital from August 2018 to July 2023. During target volume delineation, precautions were taken to avoid the reconstructed tissues, which were delineated separately. Customized HT, VMAT, and F_IMRT treatment plans were designed for each patient. The plans were categorized into the HT, VMAT, and F_IMRT groups based on different radiotherapy techniques employed. They were comparatively analyzed through one-way analysis of variance (ANOVA), with multiple comparisons further conducted in the case of significant differences.Results:Statistical analyses reveal significant differences in various parameters of target volumes among the three groups of plans ( F = 38.73, 14.95, 37.01, 48.05, 35.55, 22.56, 34.30, P < 0.05). Pairwise comparisons indicate that the maximum dose ( D2%), minimum dose ( D98%), mean dose ( Dmean), and the proportion of high-dose volumes within the target volume ( V107%and V110%) in both the HT and VMAT groups were significantly better than those in the F_IMRT group. The HT group demonstrated the optimal conformity index (CI), while the VMAT group displayed the superior homogeneity index (HI) compared to the other two groups. In terms of OAR, the V20 of the ipsilateral lung was the lowest in the HT group ( F = 14.31, P < 0.05) and the highest in the F_IMRT group ( F = 14.31, P < 0.05). However, the V5 and Dmean for both the ipsilateral and contralateral lungs in the HT group significantly surpassed those of the other groups ( F = 39.16, 31.91, P < 0.05). The mean dose Dmean ( F = 5.57, P < 0.05) of the contralateral breast was significantly reduced in the VMAT group compared to the other two groups. No statistically significant differences were observed for other OARs, including the heart, spinal cord PRV, thyroid, and humeral head ( P > 0.05). The radiation doses to reconstructed tissues ( Dmax, V53.5, Dmean) ascended in the order of HT, VMAT, and F_IMRT groups ( F = 17.69, 17.53, 15.11, P < 0.05). The HT and F_IMRT groups showed similar beam-on times ( P > 0.05), both exceeding that of the VMAT group by several folds ( F = 28.72, P < 0.05). Conclusions:The comparative analysis indicates that the three radiotherapy techniques exhibit distinct advantages and limitations, with F_IMRT demonstrating the least comprehensive advantage. HT can enhance the conformity of target volumes while reducing the overall radiation doses to reconstructed tissues and the crucial indicator V20 in the ipsilateral lung. VMAT demonstrates the highest treatment efficiency, yielding improved dose uniformity in the target volume and reduced radiation doses to the contralateral breast. It is advisable to prioritize HT or VMAT based on actual clinical conditions.
3.Influence of the complexity metrics of the multi-leaf collimator on the γ-pass rate of volumetric modulated arc therapy plans for nasopharyngeal carcinoma
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Weixue LIANG ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):309-316
Objective:To investigate the influence of the complexity metrics of the multi-leaf collimator (MLC) on the γ-pass rate of volumetric modulated arc therapy (VMAT) plans for nasopharyngeal carcinoma (NPC).Methods:A total of 60 VMAT plans for NPC were selected to measure the γ-pass rate. The MLC data across all control points (CPs) in each VMAT plan were analyzed to calculate the mean field area (MFA), average leaf gap (ALG), small aperture score (SAS), and their corresponding weighted metrics including MFAW, ALGW, and SASW, considering dose weight (W). Pearson′s bivariate correlation analysis was conducted to examine the correlations between MLC complexity metrics and the γ-pass rate. Moreover, the receiver operating characteristic (ROC) analysis was employed to assess the predictive efficacy of MLC complexity metrics on dose verification result.Results:Under the 3%/3 mm, 3%/2 mm, and 2%/2 mm criteria, the MFA in the 60 VMAT plans exhibited a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.72, P<0.05), and the MFAW was also positively correlated with the γ-pass rate ( r=0.83, 0.81, 0.75, P<0.05). The ALG manifested a positive correlation with the γ-pass rate ( r=0.82, 0.79, 0.74, P<0.05), as did the ALGW ( r=0.83, 0.81, 0.77, P<0.05). The SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) displayed negative correlations with the γ-pass rate ( r= -0.86, -0.82, -0.71, -0.84, -0.82, -0.72, -0.79, -0.79, -0.73, -0.30, -0.35, -0.42, P<0.05), whereas the SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) showed positive correlations with the γ-pass rate ( r=0.49, 0.45, 0.33, 0.73, 0.71, 0.59, 0.79, 0.79, 0.76, P<0.05). The outcomes of SASW reveal slightly stronger correlations than those of SAS. In terms of correlations among complexity metrics, a positive correlation was observed between MFA and ALG ( r=0.98, P<0.05). ALG was negatively correlated with SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), and SAS(3-4 cm) ( r= -0.95, -0.94, -0.89, -0.39, P<0.05), and positively correlated with SAS(4-5 cm), SAS(5-6 cm), and SAS(6-40 cm) ( r=0.51, 0.77, 0.92, P<0.05). The weighted result mirrored these correlations. The ROC-derived analytical result indicate that MFA, MFAW, ALG, ALGW, SAS(0-1 cm), SAS(1-2 cm), SAS(2-3 cm), SAS(6-40 cm), SASW(0-1 cm), SASW(1-2 cm), SASW(2-3 cm), and SASW(6-40 cm) demonstrated exceptional predictive efficacy for dose verification result [Area under the curve (AUC) > 0.9, P<0.05]. Conclusions:The γ-pass rate of VMAT plans for NPC is strongly correlated with MLC complexity metrics, which demonstrate excellent predictive efficacy for dose verification result. The increased uncertainty in dose calculations and measurements caused by narrow fields generated by the MLC is a significant factor contributing to the reduced γ-pass rate of VMAT plans. This finding is associated with discrepancies in the precision of treatment planning system (TPS) modeling and the accuracy of dose verification tools, providing a reference for similar challenges.
4.A comparative study of radiotherapy using three distinct radiotherapy techniques following immediate breast reconstruction for breast cancer
Xiantao HE ; Zhuohua XU ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(4):317-324
Objective:To investigate the differences in dosimetric parameters for target volumes and organs at risk (OARs), radiation doses to reconstructed tissues, and beam-on time in radiotherapy among helical tomotherapy (HT), volumetric modulated arc therapy (VMAT), and fixed-field intensity-modulated radiotherapy (F_IMRT) following immediate breast reconstruction for breast cancer, thereby providing a reference for the selection of clinical radiotherapy techniques.Methods:This study retrospectively investigated 15 breast cancer patients who underwent radiotherapy following modified radical mastectomy and immediate breast reconstruction at the Liuzhou Worker′s Hospital from August 2018 to July 2023. During target volume delineation, precautions were taken to avoid the reconstructed tissues, which were delineated separately. Customized HT, VMAT, and F_IMRT treatment plans were designed for each patient. The plans were categorized into the HT, VMAT, and F_IMRT groups based on different radiotherapy techniques employed. They were comparatively analyzed through one-way analysis of variance (ANOVA), with multiple comparisons further conducted in the case of significant differences.Results:Statistical analyses reveal significant differences in various parameters of target volumes among the three groups of plans ( F = 38.73, 14.95, 37.01, 48.05, 35.55, 22.56, 34.30, P < 0.05). Pairwise comparisons indicate that the maximum dose ( D2%), minimum dose ( D98%), mean dose ( Dmean), and the proportion of high-dose volumes within the target volume ( V107%and V110%) in both the HT and VMAT groups were significantly better than those in the F_IMRT group. The HT group demonstrated the optimal conformity index (CI), while the VMAT group displayed the superior homogeneity index (HI) compared to the other two groups. In terms of OAR, the V20 of the ipsilateral lung was the lowest in the HT group ( F = 14.31, P < 0.05) and the highest in the F_IMRT group ( F = 14.31, P < 0.05). However, the V5 and Dmean for both the ipsilateral and contralateral lungs in the HT group significantly surpassed those of the other groups ( F = 39.16, 31.91, P < 0.05). The mean dose Dmean ( F = 5.57, P < 0.05) of the contralateral breast was significantly reduced in the VMAT group compared to the other two groups. No statistically significant differences were observed for other OARs, including the heart, spinal cord PRV, thyroid, and humeral head ( P > 0.05). The radiation doses to reconstructed tissues ( Dmax, V53.5, Dmean) ascended in the order of HT, VMAT, and F_IMRT groups ( F = 17.69, 17.53, 15.11, P < 0.05). The HT and F_IMRT groups showed similar beam-on times ( P > 0.05), both exceeding that of the VMAT group by several folds ( F = 28.72, P < 0.05). Conclusions:The comparative analysis indicates that the three radiotherapy techniques exhibit distinct advantages and limitations, with F_IMRT demonstrating the least comprehensive advantage. HT can enhance the conformity of target volumes while reducing the overall radiation doses to reconstructed tissues and the crucial indicator V20 in the ipsilateral lung. VMAT demonstrates the highest treatment efficiency, yielding improved dose uniformity in the target volume and reduced radiation doses to the contralateral breast. It is advisable to prioritize HT or VMAT based on actual clinical conditions.
5.Reconstruction points of intrauterine applicator in intracavitary brachytherapy for cervical cancer
Yongfu FENG ; Shaojun CHEN ; Yusong LONG ; Junwen TAN ; Xiantao HE ; Gang LI ; Chengjun FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2024;33(9):825-832
Objective:To evaluate the effect of different reconstruction points of intrauterine applicator on the source dwell positions and plan dosimetry in intracavitary brachytherapy for cervical cancer.Methods:Clinical data of 43 patients with cervical cancer who had completed radical radiotherapy in Liuzhou Workers' Hospital from May 2020 to October 2022 were retrospectively analyzed. Among 43 patients, aged 32-79 years, 40 cases were diagnosed with squamous carcinoma and 3 cases of adenocarcinoma. All patients received external irradiation for 50.4 Gy / 28 fractions and CT-guided intracavitary brachytherapy (45° intrauterine applicator) was 36 Gy / 6 fractions. Brachytherapy was performed by using Fletcher applicator, the curvature of intrauterine applicator were 15°, 30°and45°. Two sets of brachytherapy plans were simulated for each patient. One set of plans extracted the simulated CT positioning images and the original plan of the patient's brachytherapy. The reconstruction point of the curved part of the 45° intrauterine applicator was adjusted to slice-by-slice reconstruction. The plan was optimized to meet clinical requirements according to the prescription, which was called the slice-by-slice group. In the other set of plans, slice-by-slice group was used as a template. The reconstruction points of the curved section of the 45° intrauterine applicator were adjusted to 1, 3, 5, and 7, without modifying the applicator weights and other parameters, which was called the average group 1, 3, 5 and 7. The deviation analysis of 15°, 30° and 45° intrauterine applicator with different number of reconstruction points was carried out, the reconstruction deviation of 45°, 30° and 15° intrauterine applicator at different reconstruction points was compared. Paired-sample t-test or Wilcoxon signed rank test were used to compare the differences in high-risk clinical target volume (HR-CTV) D 50%, D 90%, D 100%, V 100%, V 150%, V 200% and conformity index (CI) as well as D 2 cm3, D 1 cm3 and D 0.1 cm3 in bladder, rectum, and small intestine between two groups of 45° intrauterine applicator. Results:The reconstruction deviation in the average group was mainly from the vertical direction of the 45° intrauterine applicator. The mean reconstruction deviations of 45° (1, 3, 5, 7 reconstruction points), 30° (1, 3, 5 reconstruction points) and 15° (1, 2 reconstruction points) were 1.30 mm, 0.32 mm, 0.14 mm and 0.08 mm; 0.57 mm, 0.14 mm and 0.06 mm; 0.14 mm and 0.06 mm, respectively. There was no significant difference in the parameters of high-risk clinical target volume (HR-CTV) in the slice-by-slice group compared with the average group 5 and 7 (all P>0.005), and no significant difference was found between the average group 5 and 7 (all P>0.005). There were no statistically significant differences in bladder and rectum doses between the slice-by-slice group and the average groups or within the average groups (all P>0.005). The parameters of small intestine in the slice-by-slice group were higher than those of the average group 1, the difference was statistically significant ( P=0.002,<0.001,<0.001). The dose of small intestine in the slice-by-slice group was not statistically significant compared with those in the average group 5 and 7 (both P>0.005). The dose of small intestine in the average group 5 was not statistically significant compared with that in the average group 7 ( P>0.005). The small intestine dose deviations of D 0.1 cm3, D 1 cm3 and D 2 cm3 in the average groups at 1 reconstruction point were 2.41%±1.70%, 1.95%±1.27% and 1.71%±1.10%, respectively. Conclusion:The number of reconstruction points is recommended to be no less than 1, 3 and 5 of the curved part of the 15°, 30°and 45° Fletcher intrauterine applicator, respectively, during intracavitary brachytherapy for cervical cancer.
6.Correlation between monitor units and pass rate of plan dose verification in VMAT plan for different cancers
Junwen TAN ; Yusong LONG ; Xiantao HE ; Gang LI ; Yongfu FENG ; Zhanyu WANG
Chinese Journal of Radiation Oncology 2023;32(6):546-550
Objective:To analyze the correlation between the monitor units and pass rate of plan dose verification in the volumetric intensity modulated arc therapy (VMAT) plan.Methods:VMAT plans for 20 patients with nasopharyngeal carcinoma (NPC) and 30 patients with cervical cancer who underwent radiotherapy at Liuzhou Workers' Hospital from January to October 2020 were retrospectively chosen. The Detector 1500 array and Octavius 4D phantom from German PTW company were used for dose measurement. The pass rates of dose verification of relevant plans were analyzed under the conditions of 3%/2 mm and 2%/2 mm. The correlation between the monitor units and pass rate of plan dose verification in VMAT plans was assessed by Pearson's bivariate correlation analysis.Results:Under the condition of 3%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.873 ( P<0.001), -0.800 ( P<0.001), -0.781 ( P<0.001), -0.493 ( P=0.006) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Under the condition of 2%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.842 ( P<0.001), -0.770 ( P<0.001), -0.748 ( P<0.001) and -0.531 ( P=0.003) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Conclusion:Significant negative correlation can be observed between the monitor units and plan dose verification pass rate in VMAT plan.
7.Species identification and phylogenetic analysis of canine Leishmania in Diebu County, Gansu Province
Dawei YU ; Fan LI ; Yu FENG ; Chengming YANG ; Junke YANG ; Yongfu ZHANG ; Cheng WANG
Chinese Journal of Endemiology 2022;41(5):351-355
Objective:To investigate the species types and phylogenetic relationship of canine Leishmania in Diebu County, Gansu Province, so as to provide a basis for exploring new methods of prevention and control of canine visceral leishmaniasis. Methods:DNA was extracted from blood samples of eight asymptomatic Leishmania-infected dogs in Luoda administrative village in Diebu County, Gansu Province. Ribosomal internal transcribed spacer 1 (ITS-1) gene fragments were amplified and isolated by PCR, and then the amplified target fragments were sequenced. The MEGA 7.0 software was used for multiple sequence alignment, and a phylogenetic tree was constructed by neighbor-joining method to analyze the phylogenetic relationship of canine Leishmania in Diebu County, Gansu Province. Results:Fragments of about 320 bp corresponding in size to the target sequence ITS-1 were isolated from all of the eight asymptomatic Leishmania-infected dogs blood samples. ITS-1 sequence alignment showed that the sequence homology between 8 samples and Leishmania infantum MG969403, MN648755 strains was 99.1% - 100.0%; phylogenetic tree showed that all 8 samples were clustered into one branch with Leishmania infantum. Conclusion:Leishmania infantum is identified from all of the eight asymptomatic Leishmania-infected dogs blood samples in Diebu County, Gansu Province.
8.Application of helical tomotherapy in the treatment of synchronous bilateral breast cancer
Xiantao HE ; Yusong LONG ; Junwen TAN ; Gang LI ; Yongfu FENG ; Hui YANG ; Ying LU ; Zhanyu WANG
Chinese Journal of Radiological Medicine and Protection 2022;42(12):943-949
Objective:To study the differences in the dosimetry and delivery time between helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) in postoperative radiotherapy of synchronous bilateral breast cancer (SBBC) and to explore the feasibility of clinical application of the HT technology.Methods:A retrospective analysis was conducted for nine SBBC patients who underwent modified radical postoperative radiotherapy in the Fourth Affiliated Hospital of Guangxi Medical University from February 2017 to May 2022. For each patient, the Precision planning system was used to formulate the HT plan, and the RayStation planning system was employed to develop the VMAT plan. All plans obtained were divided into HT group and VMAT group according to plan type. The paired sample t-test was used to compare the dosimetric parameters of the target volume and organ at risk (OAR) and delivery time between the two radiotherapy technologies. Results:The plans of both groups could meet the clinical treatment requirements. The coverage ( D95% and V100%), conformity index (CI), average dose ( Dmean), and median dose ( D50%) of the target volumes in the HT group were better than those in the VMAT group, and the differences were statistically significant ( t=-3.21, -3.39, -5.03, 3.76, 4.97, P < 0.05). The differences in the maximum dose ( D2%), minimum dose ( D98%), high dose volumes ( V107% and V110%), and homogeneity index (HI) of the target volumes between the two groups were not statistically significant ( P > 0.05). Regarding the OAR, the V20 and Dmean of both lungs in the HT group were significantly lower than those in the VMAT group, but the irradiation volume V5 of both lungs in the HT group was significantly higher than that in the VMAT group ( t=-3.01, 3.83, -2.81, P < 0.05). Moreover, V20, V30, V40, and Dmean of heart and the V20 and Dmean of liver in the HT group were significantly lower than those in the VMAT group, with statistically significant differences ( t=3.76, -2.83, -2.74, 5.93, 4.57, 4.48, P < 0.05). There was no significant difference in the radiation doses to other OARs (spinal cord, thyroid gland, and humerus head, P > 0.05). The delivery time of the HT group was significantly higher than that of the VMAT group ( t = 11.32, P < 0.05). Conclusions:Compared with VMAT, HT has greater dosimetric advantages, and can provide higher target coverage, conformability and average dose, and significantly reduce the overall radiation doses to both lungs, heart, and liver in OARs. However, the irradiation volume V5 at low-dose areas of both lungs and the delivery time in the HT group are higher than those in the VMAT group, but still meet the clinical treatment requirements. Therefore, it is feasible to apply the HT technology to the modified radical postoperative radiotherapy of SBBC.
9.Safety and efficacy evaluation of laparoscopic and open hepatectomy for hepatolithiasis: a propensity score matched analysis
Xujian HUANG ; Yi HE ; Li HE ; Yanjie FENG ; Gang YANG ; Yongfu XIONG ; Jingdong LI
Chinese Journal of Surgery 2022;60(6):593-598
Objective:To compare the safety and efficacy of laparoscopic and open hepatectomy for hepatolithiasis.Methods:Between January 2014 and May 2020, the clinicopathological data of 254 patients with hepatolithiasis who underwent laparoscopic or open hepatectomy at the First Department of Hepatobiliary Surgery,Affiliated Hospital of North Sichuan Medical College were collected retrospectively. There were 74 males and 180 females with age of (56±8) years (range: 38 to 77 years). Of the 254 patients, 162 underwent laparoscopic surgery (laparoscopic group) and 92 underwent open surgery (open group). Propensity score matching(PSM) was performed to match baseline characteristics of the two groups,and then the perioperative results and follow-up efficacy were compared between the two groups. The t-test, Mann-Whitney U test, χ 2 test or Fisher′s exact probability method was used to compare the perioperative data and follow-up results of the two groups after matching, respectively. Results:Each group had 63 patients after PSM with well-balanced baseline characteristics. There was no statistic difference in the type of hepatectomy,combined common bile duct exploration rate,T tube drainage placement rate,operation time,intraoperative transfusion rate,intraoperative accidental injury rate,initial and final stone clearance rate,and stone recurrence rate between the two groups. However,compared with the open hepatectomy group, the laparoscopic group had significantly lower intraoperative blood loss ( M(IQR))(300(175)ml vs. 350(145)ml, Z=3.227, P=0.001),shorter postoperative hospital stay((10.6±4.1)days vs. (14.0±4.0)days, t=4.634, P<0.01),shorter time to postoperative oral intake ((1.8±1.1)days vs. (2.9±1.6)days, t=4.556, P<0.01), and lower postoperative complication rate (25.4%(16/63) vs. 49.2%(31/63), χ2=7.635, P=0.006). Conclusion:Laparoscopic hepatectomy is safe and effective for hepatolithiasis with the advantages of less intraoperative blood loss,lower postoperative complications and faster postoperative recovery.
10.Safety and efficacy evaluation of laparoscopic and open hepatectomy for hepatolithiasis: a propensity score matched analysis
Xujian HUANG ; Yi HE ; Li HE ; Yanjie FENG ; Gang YANG ; Yongfu XIONG ; Jingdong LI
Chinese Journal of Surgery 2022;60(6):593-598
Objective:To compare the safety and efficacy of laparoscopic and open hepatectomy for hepatolithiasis.Methods:Between January 2014 and May 2020, the clinicopathological data of 254 patients with hepatolithiasis who underwent laparoscopic or open hepatectomy at the First Department of Hepatobiliary Surgery,Affiliated Hospital of North Sichuan Medical College were collected retrospectively. There were 74 males and 180 females with age of (56±8) years (range: 38 to 77 years). Of the 254 patients, 162 underwent laparoscopic surgery (laparoscopic group) and 92 underwent open surgery (open group). Propensity score matching(PSM) was performed to match baseline characteristics of the two groups,and then the perioperative results and follow-up efficacy were compared between the two groups. The t-test, Mann-Whitney U test, χ 2 test or Fisher′s exact probability method was used to compare the perioperative data and follow-up results of the two groups after matching, respectively. Results:Each group had 63 patients after PSM with well-balanced baseline characteristics. There was no statistic difference in the type of hepatectomy,combined common bile duct exploration rate,T tube drainage placement rate,operation time,intraoperative transfusion rate,intraoperative accidental injury rate,initial and final stone clearance rate,and stone recurrence rate between the two groups. However,compared with the open hepatectomy group, the laparoscopic group had significantly lower intraoperative blood loss ( M(IQR))(300(175)ml vs. 350(145)ml, Z=3.227, P=0.001),shorter postoperative hospital stay((10.6±4.1)days vs. (14.0±4.0)days, t=4.634, P<0.01),shorter time to postoperative oral intake ((1.8±1.1)days vs. (2.9±1.6)days, t=4.556, P<0.01), and lower postoperative complication rate (25.4%(16/63) vs. 49.2%(31/63), χ2=7.635, P=0.006). Conclusion:Laparoscopic hepatectomy is safe and effective for hepatolithiasis with the advantages of less intraoperative blood loss,lower postoperative complications and faster postoperative recovery.

Result Analysis
Print
Save
E-mail