1.Bridging fixation with locking plate for the treatment of subtrochanteric femoral fractures of Seinsheimer type V.
Yin-wen LIU ; Yu-xin ZHENG ; Zi-liang SHEN ; Shu-qiang WANG ; Xiao-en WEI ; Lei ZHANG ; Xin-feng GU ; Yong KUANG ; Hong-sheng ZHAN ; Yin-yu SHI
China Journal of Orthopaedics and Traumatology 2016;29(1):68-72
OBJECTIVETo investigate the clinical effect of bridging fixation with locking plate for the Seinsheimer type V subtrochanteric femoral fracture.
METHODSFrom March 2009 to September 2014,18 cases of Seinsheimer type V subtrochanteric femoral fracture were treated by open reduction and bridging fixation with locking plate through proximal and distal approach including 16 males and 2 females with an average age of 41 years old ranging from 22 to 67 years old. Among them, 12 cases caused by traffic accident, 5 cases by falling, 1 case by heavy aboving. All cases were fresh and closed fractures. Time between injury and operation was from 4 to 9 days with an average of 6.2 days. Of them, 11 cases were fixed with reverse LISS and the other 7 cases were fixed with anatomical locking plates of proximal femur.
RESULTSThe mean time of operation was 110 min (ranged from 90 to 155 min). The mean blood loss during operation was 425 ml (ranged from 350 to 650 ml) and 16 cases got blood transfusion which was meanly 300 ml. The mean hospital time was 14 days (ranged from 12 to 18 days). The mean duration of followed up was 11.8 months (ranged from 8 to 22 months). The mean time of bone union was 6.6 months (ranged from 5 to 8 months). There was not any complication such as infection, implant failure, hip varus, external rotation deformity of low limb or fat embolism. The Sanders hip scores were 53.22 ± 6.48, the result was excellent in 12 cases and good in 6 cases at the last follow-up.
CONCLUSIONUnder the principle of biological osteosynthesis, treatment of Seinsheimer type V subtrochanteric femoral fracture with bridging locking plate fixation has such advantages as high mechanism, less interference of blood supply, stable fixation and little complication. It is a safe and idea way for the treatment of the Seinsheimer type V subtrochanteric femoral fracture.
Adult ; Aged ; Bone Plates ; Female ; Fracture Fixation, Internal ; methods ; Hip Fractures ; surgery ; Humans ; Male ; Middle Aged
2.A study of proximal humerus fractures using close reduction and percutaneous minimally invasive fixation.
Yin-wen LIU ; Yong KUANG ; Xin-feng GU ; Yu-xin ZHENG ; Zhi-qiang LI ; Xiao-en WEI ; Wei-da LU ; Hong-sheng ZHAN ; Yin-yu SHI
China Journal of Orthopaedics and Traumatology 2011;24(11):949-951
OBJECTIVETo investigate the clinical effects of close reduction and percutaneous minimally invasive fixation in the treatment of proximal humerus fractures.
METHODSFrom April 2008 to March 2010, 28 patients with proximal humerus fracture were treated with close reduction and percutaneous minimally invasive fixation. There were 21 males and 7 females, ranging in age from 22 to 78 years,with an average of 42.6 years. The mean time from suffering injuries to the operation was 1.7 d. Nineteen cases caused by falling down, 9 cases by traffic accident. The main clinical manifestation was swelling, pain and limited mobility of shoulders. According to Neer classification, two part fractures were in 17 cases and three part fractures in 11 cases. The locking proximal humerus plate was used to minimally fixation through deltoid muscle under acromion. The operating time,volume of blood loss, the length of incision and Constant-Murley assessment were applied to evaluate the therapeutic effects.
RESULTSThe mean operating time was 40 min, the mean blood loss was 110 ml, and the mean length of incision was about 5.6 cm. The postoperative X-ray showed excellent reduction and the plate and screws were successfully place. Twenty-eight patients were followed up for 6 to 24 months (averaged 14.2 months). The healing time ranged from 6 to 8 weeks and all incision was primarily healed. There were no cases with necrosis head humerus, 24 cases without omalgia, and 4 cases with o-malgia occasionally. All the patients can complete the daily life. The mean score of Constant-Murley assessment was 91.0 +/- 5.8, 24 cases got an excellent result, 3 good and 1 fair.
CONCLUSIONClose reduction and percutaneous minimally invasive fixation, not only can reduce surgical invasive, but also guarantee the early function activities. It has the advantages of less invasive, fixed well and less damage of blood circulation.
Adult ; Aged ; Female ; Fracture Healing ; Humans ; Male ; Middle Aged ; Minimally Invasive Surgical Procedures ; methods ; Shoulder Fractures ; physiopathology ; surgery
3.Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients.
Yin-Wen LIU ; Yong KUANG ; Xin-Feng GU ; Yu-Xin ZHENG ; Zhi-Qiang LI ; Xiao-En WEI ; Ming-Cai ZHANG ; Hong-Sheng ZHAN ; Yin-yu SHI
China Journal of Orthopaedics and Traumatology 2013;26(3):248-251
OBJECTIVETo evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures.
METHODSFrom March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated.
RESULTSThe mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair.
CONCLUSIONTreatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue injury, less blood loss, reliable fixation, which is effective method in treating proximal and distal tibial fractures and corresponds with the standpoint of biological fixation.
Adult ; Aged ; Bone Plates ; Female ; Fracture Fixation, Internal ; methods ; Humans ; Male ; Middle Aged ; Minimally Invasive Surgical Procedures ; methods ; Tibial Fractures ; surgery
4.Case-control study on close reduction combined with minimally invasive percutaneous plate osteosynthesis for the treatment of distal fracture of tibial shaft.
Yin-Wen LIU ; Yu-Xin ZHENG ; Xue-Zong WANG ; Hu ZHANG ; Mu-Zheng SUN ; Wei XIAO-EN ; Gu XIN-FENG ; Yong KUANG ; Lei ZHANG ; Zi-Liang SHEN ; Hong-Sheng ZHAN ; Yin-Yu SHI
China Journal of Orthopaedics and Traumatology 2015;28(3):230-234
OBJECTIVETo compare the effects of close reduction combined with minimally invasive percutaneous plate osteosynthesis for distal fracture of tibial shaft.
METHODSFrom March 2009 to May 2013, there were 124 patients (89 males and 35 females, 30 of them were injured in a traffic accident and 94 were falling down in daily life, the ages ranging from 21 to 81 years old) who suffered from distal fracture of tibial shaft. Sixty-six patients (48 males and 18 females, 45 cases of type A, 12 cases of type B and 9 cases of type C) were treated with close manipulative reduction combined with minimally invasive percutaneous plate fixation. After close reduction, a minimal incision was made and a anatomic plate was inserted just along the medial tibia periostea, and then the fracture was fixed without fracture exposure. The other 58 patients (41 males and 17 females, 41 cases of type A, 10 cases of type B and 7 cases of type C) were treated with conventional open reduction and internal fixation. Length of the incision, operating time, early postoperative pain (recorded using the Visual Analog Scale score) and the outcome results (recorded using the evaluation standard of Johner-Wruhs) were compared.
RESULTSThe length of incision was meanly (7.34 ± 1.42) cm in MIPPO group and (21.82 ± 2.35) cm in ORIF group; operation time was (44.48 ± 10.00) min in MIPPO group and (59.42 ± 11.84) min in ORIF group. The postoperative radiographs verified good position of all screws and satisfactory bone fracture reduction in both groups. All the patients were followed up, and the duration ranged from 10 to 24 months (mean 15.2 months) in both groups. In MIPPO group,only one patient had delayed union and got union after Chinese herb therapy. The other 65 patients got bony union during 15 to 20 weeks. While in ORIF group, 3 patients suffered from nonunion and received reoperation with bone grafting, and 4 patients got bone infection.
CONCLUSIONTreatment of distal fracture of tibial shaft, combined with close reduction and MIPPO technique, has the advantages such as less invasion, less damage of blood supply, simplified procedure of operation and higher union rate, which is an ideal methods and is accordant to the biological demand.
Adult ; Aged ; Aged, 80 and over ; Bone Plates ; Case-Control Studies ; Female ; Fracture Fixation, Internal ; methods ; Humans ; Male ; Manipulation, Orthopedic ; methods ; Middle Aged ; Tibial Fractures ; therapy
5.Efficacy and safety of argon plasma coagulation in the treatment of obstructive tracheobronchial stenosis.
Fa-guang JIN ; De-guang MU ; Dong-ling CHU ; En-qing FU ; Yong-hong XIE ; Tong-gang LIU ; Xing GU
Chinese Journal of Oncology 2008;30(6):462-464
OBJECTIVETo evaluate the efficacy and safety of argon plasma coagulation (APC) in the treatment of large airway obstruction.
METHODSTotally 389 patients with treacheobronchial stenosis were treated with APC (ARCO3000 type) by bronchoscopy. The stenoses were caused by carcinomas (203 cases, 52.2%), metastatic tumors (67 cases, 17.2%), benign tumors (18 cases, 4.6%), granulomas (93 cases, 23.9%) and other lesions (8 cases, 2.1%). The rate of recanalization, relief of the symptoms, and complications were analyzed.
RESULTS1121 times of APC treatment were performed in the 389 patients. Complete recanalization was achieved in 138 cases (35.5%), partial in 143 (36.8%), mild in 55 (14.1%) and none in 53 (13.6%). The major complications included: super-ventricular tachycardia in 136 cases (34.9%), bleeding in 51 (13.1%), decrease in blood oxygen saturation in 48 (12.3%), asphyxia in 33 (8.5%), ventricular or super-ventricular arrhythmia in 24 (6.2%), short-term aggravation of airway obstruction in 18 (4.6%), and tracheal perforation in 3 (0.78%). All those complications were treated with various measures and no patient died of the complications during the procedure.
CONCLUSIONArgon plasma coagulation is effective and relatively safe in relieving the obstruction and dyspnea in patients with large airway obstruction caused by various reasons. However, for the patients with severe airway obstruction, argon plasma coagulation sometimes may cause severe or even lethal complications. Critical consideration of the indication, operators' skill and taking more precautions during the procedure are required to ensure the safety of argon plasma coagulation treatment.
Adolescent ; Adult ; Aged ; Aged, 80 and over ; Argon ; therapeutic use ; Bronchial Diseases ; etiology ; surgery ; Bronchial Neoplasms ; complications ; Bronchoscopy ; Constriction, Pathologic ; Electrocoagulation ; methods ; Female ; Humans ; Male ; Middle Aged ; Retrospective Studies ; Tracheal Neoplasms ; complications ; Tracheal Stenosis ; etiology ; surgery ; Young Adult
6.Impact of specimen collection and storage consumable products on trace element quantitative analysis.
Yan-shuang SONG ; Yong-en GU ; Te BA ; Min ZHAI ; Ji PU ; Zhen-lin SHEN ; Shi-chuan TANG ; Guang JIA
Chinese Journal of Preventive Medicine 2012;46(7):640-643
OBJECTIVEThis study aimed to explore the impact of specimen collection and storage consumable products on trace element quantitative analysis.
METHODSDevices and consumable products of different brands used in specimen collection or storage were selected and treated separately as below:urine collection and storage tubes (Brand A, B, C and D, 2 samples for each brand) were treated with 1% of HNO(3) volume fraction for 2 - 4 h; blood taking device (Brand O, P and Q, 3 samples for each brand) were used for ultra-pure water samples collecting as simulation of blood sampling;dust sampling filters (Brand X, Y and Z, 2 samples for each brand) were cold digested by nitric acid for 12 h, followed by microwave digestion. Then cadmium, cobalt, chromium, copper, iron, manganese, molybdenum, nickel, lead, selenium, stannum, titanium, vanadium and zinc concentrations in the solutions obtained during the course of collect or storage were quantified by inductively coupled plasma mass spectrometer.
RESULTSFor the urine collection and storage consumable products, background values of elements were described as mean of parellel samples. The consentration of 14 quantified elements were relatively low for 5 ml cryogenic vials (brand B) with background values range of 0.001 - 0.350 ng/ml. The background values of copper of 50 ml centrifuge tubes (brand A), chromium of 5 ml cryogenic vials (brand C) and zinc of 1.5 ml centrifuge tubes (brand D) were relatively high, which were 1.900, 1.095 and 1.368 ng/ml, respectively. Background values of elements in blood sampling devices were described as x(-) ± s. Background values of chromium for brand O, P and Q were (0.120 ± 0.017), (0.337 ± 0.093) and (0.360 ± 0.035) ng/ml; for copper were (0.050 ± 0.001), (0.017 ± 0.012) and (0.103 ± 0.015) ng/ml; for lead were (0.057 ± 0.072), (0.183 ± 0.118) and (0.347 ± 0.006) ng/ml; for titanium were (7.883 ± 0.145), (8.863 ± 0.190) and (8.613 ± 0.274) ng/ml; zinc were (2.240 ± 0.573), (42.140 ± 22.756) and (8.850 ± 3.670) ng/ml. There were statistically differences of background values for chromium, copper, lead, titanium and zinc among the above three brands of blood sampling devices (all P values < 0.05). For air sampling filters, background values of elements were described as mean of parellel samples. Background values of chromium and nickel of sampling filters (brand X) were lowest, which were 17.000 and 15.400 ng per piece, respectively; while background values for other elements were relatively high, the quantification of cadmium, cobalt, copper, iron, manganese, molybdenum, lead, selenium, stannum, titanium, vanadium and zinc were 0.250, 0.550, 48.500, 690.000, 25.500, 0.900, 6.500, 10.550, 7.950, 10.500, 0.850, 370.000 ng per piece, respectively. Background values of chromium and nickel of sampling filters (brand Z) were highest, which were 171.000 and 29.850 ng per piece.
CONCLUSIONBackground values of trace elements varied among products of different brands, and the most noticable differences were found in chromium, manganese, nickel, lead, stannum and zinc.
Environmental Monitoring ; methods ; Quality Control ; Specimen Handling ; methods ; Trace Elements ; analysis
7.Evidence-based study of chromate exposed workers' health surveillance indexes.
Yong-en GU ; Qin QIAN ; Shan-fa YU ; Ji ZHANG ; Li WANG ; Zu-chang ZHAO ; Yan-shuang SONG ; Tian CHEN ; Jing-Lin YANG ; Tian-Cheng WANG ; Yun WANG ; Guang JIA
Chinese Journal of Preventive Medicine 2013;47(9):848-854
OBJECTIVEThe health surveillance proposal for chromate exposed workers was provided and analyzed on the evidence-based study and then to be improved.
METHODFirstly, the related literatures were searched about liver damage, micronuclei, urinary chromium and hexavalent chromium exposure in Evidence Based Medicine Reviews such as Cochran library, OVID Medline, Web of knowledge in December 2011; and then, these literatures were reviewed in according to inclusion and exclusion criteria; 22 articles totally were retrieved, evaluated and classified in according to the grading standard by Oxford Centre for Evidence-based Medicine.Finally, field epidemiological investigation was further adopted to confirm the efficiency and feasibility of this proposal, combined with cost-effectiveness analysis:the ratio of total cost divided survival years was used to express the cost-effectiveness.
RESULTOnly the glutamic pyruvic transaminase test could not reflect liver damage caused by chromate exposure well; Urinary chromium correlated well with the index reflecting body damage caused by chromate exposure; Binucleated cells micronucleus index in peripheral blood lymphocyte could reflect the genetic damage caused by chromate exposure. As for health economic evaluation of chromate lung cancer, the value of cost/effectiveness was ¥42 321.61 per year that was far below the value of common people (¥252 868.97 per year) .
CONCLUSIONIt was suggested that serum glutamic pyruvic transaminase test should be replaced by liver function test, urinary chromium should be classified as a compulsory index and binucleated cells micronucleus index in peripheral blood lymphocyte should be supplied as a recommended index.
Alanine Transaminase ; blood ; Chromates ; urine ; Evidence-Based Medicine ; Humans ; Micronucleus Tests ; Occupational Exposure ; Population Surveillance
8.Korean Multicenter Study of Te tanus Antibody Titer (KoMUST).
Ho Jung KIM ; Gu Hyun KANG ; Gi Woon KIM ; Sang Chul KIM ; Young Sik KIM ; Chun Ho KIM ; Hee Cheol AHN ; Se Hyun OH ; Yoo Sang YOON ; Kang Hyun LEE ; Sam Woo LEE ; Jae Bae LEE ; Jin Woong LEE ; Tai Ho IM ; Jae Bong CHUNG ; Soo Hyeong CHO ; Kwang Won CHO ; Jun Hwi CHO ; Jin Kyung CHO ; Michael SungPil CHOI ; En Seok HONG ; Yong Hwa LEE
Journal of the Korean Society of Emergency Medicine 2005;16(6):667-676
PURPOSE: We determine the Korean antibody titer and positive rate of tetanus by using a with qualitative test (ELISA) and a quantitative test (TQS(R)). METHODS: This study was prospective collecting study with uncontolled patients who were admitted in 21 Emergency Departments during 3 months in South Korea. We measured TQS(R) and collected the serum with a centrifuge for 5 groups, which was classified with age: 2~10 years (I), 11~20 years (II), 21~30 years (III), 31~40 years (IV), 41~60 years (V), in each hospital. The freezed serum and the protocol with TQS(R) results were taken at the Soonchunhyang University Bucheon hospital to be analyzed. RESULTS: The number of enrolled patients was 1816 (male 58%). The positive rate of TQS(R) was 835 patients (46%), and there was no relation with region or sex. In sex and age, there was a definitive decline in the group III fort males and females. The results of ELISA was showed that 62.8% (> 0.15 IU/ml) and 52.2% (> 0.2 IU/ml) had protective levels of tetanus antibody. The proportion decreased to approximately 43% and 18% among persons 40~60 years of age at each level of antibody titers. By region and population, there was no statistical relationship with TQS(R) and ELISA, but previous military service was associated with a higher prevalence of protective antibodies to tetanus (p<0.001). CONCLUSIONS: A substantial portion of adults in South Korea do not have antibody levels that are protective against tetanus. Also, the mean level of tetanus antibody titers was definitively lower than those of other developed conturies and consistently decreased with aging. Therefore, an adult formulation diphteria and tetanus toxoid every 5 or 10 years is recommended for all adults between 20 and 60 years of age after being tested with TQS(R) in South Korea.
Adult
;
Aging
;
Antibodies
;
Emergency Service, Hospital
;
Enzyme-Linked Immunosorbent Assay
;
Epidemiology
;
Female
;
Gyeonggi-do
;
Humans
;
Korea
;
Male
;
Military Personnel
;
Prevalence
;
Prospective Studies
;
Tetanus
;
Tetanus Toxoid