1.Construction and Optimization of Alzheimer's Disease Classification Model Based on Brain Mixed Function Network Topology Parameters and Machine Learning
Xiao-yu HAN ; Xiu-zhu JIA ; Yang LI ; Meng-ying LOU ; Yong-qi NIE ; Xin-ping GUO ; Lu YU ; Zhi-yuan LI ; Lian-zheng SU
Progress in Modern Biomedicine 2025;25(11):1770-1778
Objective:To explore the interrelationship between brain functional networks and features in functional magnetic resonance imaging(fMRI)of patients with Alzheimer's disease(AD),and to construct mixed-function networks(MFN),and apply them in machine learning classification models to improve the accuracy of AD classification.Methods:102 AD patients and 227 healthy subjects in the Alzheimer's Neuroimaging Initiative(ADNI)dataset were retrospectively analyzed.The partial correlation brain network of the blood oxygen level dependent(BOLD)signal was calculated and fused with low-frequency wave amplitude(ALFF),fractional low-frequency wave amplitude(fALFF)and local consistency(ReHo)features to construct MFN.Network topology parameters were extracted,and a variety of machine learning classification models were constructed based on MFN topological parameters,accuracy,precision,recall and area under the curve(AUC)were used to evaluate the predictive efficiency of the models.Results:By constructed MFN and calculated intra group to inter group ratio(IIGR),35 features could be obtained from ALFF,fALFF and ReHo feature topological parameter analysis,after rank sum test and FDR correction,there were statistical differences among 28 features(P<0.05).The classification results show that,all the five classifiers have high classification performance on the test data set.The accuracy,precision and recall rates of random forest(RF),adaptive lifting algorithm(AdaBoost),guided aggregation algorithm(Bagging)and support vector machine(SVM)were all 99.7%,and the AUC values were up to 100%,99.5%,99.1%and 99.5%,respectively.The accuracy(98.5%),precision(98.5%),recall(98.5%),and AUC(99.1%)of the multi-layer perceptron(MLP)were slightly lower than other models,but remained excellent.It was worth noting that RF has the highest AUC value of all models at 100.0%,while Bagging has the lowest AUC value(99.1%)in the integrated approach.The results of performance comparison show that,MFN classification model can significantly improve the recognition and classification of AD disease,and greatly improve the performance of various indicators of the classifier.The results showed that,MFN classification model was superior to intelligent classification based fusion,DBN-based multitask learning,PVT-TSVM,unsupervised learning and clustering,SVM and SVM of degree 3 polynomial kernel function in key indicators such as accuracy(99.13%),AUC(99.42%),recall rate(99.46%)and specificity(99.42%)with plasma proteins,machine learning algorithms.It was further proved that MFN classification model has good generalization ability and robustness in AD disease classification.Conclusion:The AD classification model constructed based on brain mixed function network topology parameters and machine learning can improve the accuracy of AD classification.
2.Prediction of gastric cancer T staging using oral contrast-enhanced ultrasonography combined with contrast-enhanced CT
Aiqing LU ; Fei QIU ; Xin DONG ; Xiaoyan LI ; Xiuyun SUN ; Xuefeng LI ; Zhaoxin JIN ; Xiankai WANG ; Yong ZHANG
Chinese Journal of Radiological Health 2025;34(3):368-372
Objective To explore the value of oral contrast-enhanced ultrasonography (OCEUS) combined with contrast-enhanced CT in predicting preoperative T staging in patients with gastric cancer. Methods A retrospective analysis was conducted on 80 patients with gastric cancer confirmed via endoscopic biopsy or postoperative pathology at the First People’s Hospital of Jining from January 2021 to November 2024. The cohort included 56 males and 24 females, aged 38-79 years, with a median age of 55.9 years. All patients underwent both OCEUS and contrast-enhanced CT within one week prior to surgery. T staging of gastric cancer was determined using OCEUS, contrast-enhanced CT, or their combination. The results were compared with pathological T staging, and statistical differences in accuracy were analyzed. Results Pathological T staging identified T1 in 9 cases, T2 in 16 cases, T3 in 42 cases, and T4 in 13 cases. OCEUS indicated T1 in 6 cases, T2 in 14 cases, T3 in 50 cases, and T4 in 10 cases, with an accuracy rate of 80.0%. Contrast-enhanced CT indicated T1 in 4 cases, T2 in 12 cases, T3 in 52 cases, and T4 in 12 cases, with an accuracy rate of 75.0%. The combination of OCEUS and contrast-enhanced CT indicated T1 in 6 cases, T2 in 15 cases, T3 in 47 cases, and T4 in 12 cases, with an accuracy rate of 87.5%. The combined approach demonstrated significantly higher accuracy in preoperative T staging compared to either method alone (P < 0.05). Conclusion The combination of OCEUS and contrast-enhanced CT improves the accuracy of preoperative T staging in gastric cancer patients, providing valuable support for their diagnosis and treatment.
3.Clinical characteristics and oncological outcomes of patients with clear cell borderline ovarian tumor
Jun LI ; Wei-yong GU ; Jie-yu WANG ; Bei-bei WU ; Xin LU ; Rui-fang CHEN
Fudan University Journal of Medical Sciences 2025;52(1):55-62
Objective To explore the clinical and pathological characteristics and oncological outcomes of clear cell borderline ovarian tumor(CCBOT),and provide guidance for the diagnosis and treatment of this disease in the future.Methods A total of 23 CCBOT patients who underwent surgical treatment in our hospital from May 2011 to Aug 2022 were enrolled,and the clinical information of 19 CCBOT patients in the Ricotta's cohort was integrated.The clinical pathological characteristics and oncological outcomes of these 42 patients were retrospectively analyzed.Results This study enrolled 42 CCBOT patients,including 23 from our cohort and 19 from the Ricotta G's cohort.Compared with the Ricotta's cohort,the proportion of CCBOT patients with endometriosis in our cohort(34.8%)was significantly higher than that in the Ricotta's cohort(5.3%)(P<0.05).In our cohort,22 patients had information on intraoperative frozen section evaluation,and the accuracy of intraoperative frozen section evaluation was 50%(11/22).The other 50%(11/22)of patients were underestimated by intraoperative frozen section evaluation.The merged cohort indicated that the median age of the patients was 60 years old,occuring more common in postmenopausal women(66.7%).Most cases presented with pelvic masses(59.5%)and abdominal pain or distension(19.0%).This disease mostly involved unilateral ovaries(90.5%).Information on preoperative tumor markers was largely missed,making it difficult to draw an accurate evaluation for them.Ten cases(23.8%)underwent fertility sparing surgery,and 32 cases(76.2%)underwent radical surgery.The pathologic report indicated that all patients were stage I patients and 21.4%patients had endometriosis.Among these patients,32 patients underwent total hysterectomy,of which 10(31.3%)had concurrent endometrial lesions.The median follow-up time was 68 months,with a minimum follow-up of one month and a maximum follow-up of 231 months,and no recurrence or death was observed.Conclusion CCBOT patients usually had an good prognosis with a low recurrence rate.Fertility sparing surgery was safe and feasible,but attention should be paid to exclude concurrent endometrial lesions.Given the rarity of CCBOT,future multicenter prospective studies are needed to better elucidate the clinical pathological features and prognosis of patients with CCBOT.
4.Mechanosensory activation of Piezo1 via cupping therapy: Harnessing neural networks to modulate AMPK pathway for metabolic restoration in a mouse model of psoriasis.
Ruo-Fan XI ; Xin LIU ; Yi WANG ; Han-Zhi LU ; Shao-Jie YUAN ; Dong-Jie GUO ; Jian-Yong ZHU ; Fu-Lun LI ; Yan-Juan DUAN
Journal of Integrative Medicine 2025;23(6):721-732
OBJECTIVE:
Psoriasis, a common chronic inflammatory skin condition with genetic underpinnings, is traditionally managed with cupping therapy. Although used historically, the precise mechanical effects and therapeutic mechanisms of cupping in psoriasis remain largely unexamined. This study aimed to evaluate cupping therapy's efficacy for psoriasis and investigate its role in modulating inflammatory responses and cellular metabolism.
METHODS:
Psoriasis was induced in mice using topical imiquimod (IMQ). The effects of cupping on psoriatic lesions were assessed using the Psoriasis Area and Severity Index score, histology, immunohistochemistry, and immunofluorescence staining. polymerase chain reaction sequencing (RNA-seq) and Western blotting were conducted to examine changes in mRNA expression and the AMP-activated protein kinase (AMPK) signaling pathway.
RESULTS:
Cupping therapy significantly reduced inflammation, epidermal thickness, and inflammatory cell infiltration in mice with IMQ-induced psoriasis. Immunohistochemistry and immunofluorescence showed lower expression of inflammatory markers and a shift in T-cell populations. RNA-seq and Western blotting indicated that cupping upregulated Piezo1 and activated the AMPK pathway, improving energy metabolism in psoriatic skin.
CONCLUSION
Cupping therapy reduces epidermal hyperproliferation and inflammation in psoriasis, rebalancing the local immune microenvironment. Mechanistically, cupping promotes calcium influx via Piezo1, activates AMPK signaling, and supports metabolic homeostasis, suggesting therapeutic potential for psoriasis. Please cite this article as: Xi RF, Liu X, Wang Y, Lu HZ, Yuan SJ, Guo DJ, Zhu JY, Li FL, Duan YJ. Mechanosensory activation of Piezo1 via cupping therapy: Harnessing neural networks to modulate AMPK pathway for metabolic restoration in a mouse model of psoriasis. J Integr Med. 2025; 23(6):721-732.
Animals
;
Psoriasis/chemically induced*
;
Mice
;
AMP-Activated Protein Kinases/metabolism*
;
Disease Models, Animal
;
Cupping Therapy/methods*
;
Signal Transduction
;
Imiquimod
;
Ion Channels/genetics*
;
Male
;
Mechanotransduction, Cellular
5.Association between Fish Consumption and Stroke Incidence Across Different Predicted Risk Populations: A Prospective Cohort Study from China.
Hong Yue HU ; Fang Chao LIU ; Ke Yong HUANG ; Chong SHEN ; Jian LIAO ; Jian Xin LI ; Chen Xi YUAN ; Ying LI ; Xue Li YANG ; Ji Chun CHEN ; Jie CAO ; Shu Feng CHEN ; Dong Sheng HU ; Jian Feng HUANG ; Xiang Feng LU ; Dong Feng GU
Biomedical and Environmental Sciences 2025;38(1):15-26
OBJECTIVE:
The relationship between fish consumption and stroke is inconsistent, and it is uncertain whether this association varies across predicted stroke risks.
METHODS:
A cohort study comprising 95,800 participants from the Prediction for Atherosclerotic Cardiovascular Disease Risk in China project was conducted. A standardized questionnaire was used to collect data on fish consumption. Participants were stratified into low- and moderate-to-high-risk categories based on their 10-year stroke risk prediction scores. Hazard ratios ( HRs) and 95% confidence intervals ( CIs) were estimated using Cox proportional hazard models and additive interaction by relative excess risk due to interaction (RERI), attributable proportion (AP), and synergy index (SI).
RESULTS:
During 703,869 person-years of follow-up, 2,773 incident stroke events were identified. Higher fish consumption was associated with a lower risk of stroke, particularly among moderate-to-high-risk individuals ( HR = 0.53, 95% CI: 0.47-0.60) than among low-risk individuals ( HR = 0.64, 95% CI: 0.49-0.85). A significant additive interaction between fish consumption and predicted stroke risk was observed (RERI = 4.08, 95% CI: 2.80-5.36; SI = 1.64, 95% CI: 1.42-1.89; AP = 0.36, 95% CI: 0.28-0.43).
CONCLUSION
Higher fish consumption was associated with a lower risk of stroke, and this beneficial association was more pronounced in individuals with moderate-to-high stroke risk.
Humans
;
China/epidemiology*
;
Male
;
Female
;
Stroke/etiology*
;
Middle Aged
;
Prospective Studies
;
Incidence
;
Aged
;
Animals
;
Fishes
;
Risk Factors
;
Diet
;
Seafood
;
Adult
;
Cohort Studies
6.Preliminary study on the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
Xin LI ; Yuzong LU ; Yongtao YANG ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(5):689-695
OBJECTIVES:
This study aimed to investigate the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
METHODS:
Ten digital impressions of patients undergoing continuous crowns or fixed bridge restoration supported by two implants were obtained, and resin models with implant replicas were 3D printed. Scanning rods were fixed on the replicas 3, 7, and 14 days after printing. The 3D, linear, and angular deviations of the scanning rods at different times were analyzed through Geomagic Wrap 2021 software.
RESULTS:
The position of the replicas shifted mesiolingually, in the same direction as the shrinkage of the model. From day 7 onward, the 3D, distance linear, and angular deviations of the replicas (scanning rod) significantly increased compared with those on the 3rd day (P<0.05). On the 14th day, the changes were even more pronounced, with the above deviations showing statistical significance (P<0.05) compared with those for the 3-day and 7-day groups. No statistical difference in height linear deviation was observed among the groups.
CONCLUSIONS
The insufficient dimensional stability of 3D printed resin models can lead to changes in the relative position and angle of the replicas, thereby affecting the accuracy of the replicas in recreating the implant's position. Complete manufacturing of prosthesis is recommended within 7 days after the model is printed.
Printing, Three-Dimensional
;
Humans
;
Dental Implants
;
Models, Dental
;
Dental Impression Technique
;
Crowns
7.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
8.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures
9.Explanation and interpretation of blood transfusion provisions for children with hematological diseases in the national health standard "Guideline for pediatric transfusion".
Ming-Yi ZHAO ; Rong HUANG ; Rong GUI ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(1):18-25
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion is one of the most commonly used supportive treatments for children with hematological diseases. This guideline provides guidance and recommendations for blood transfusions in children with aplastic anemia, thalassemia, autoimmune hemolytic anemia, glucose-6-phosphate dehydrogenase deficiency, acute leukemia, myelodysplastic syndromes, immune thrombocytopenic purpura, and thrombotic thrombocytopenic purpura. This article presents the evidence and interpretation of the blood transfusion provisions for children with hematological diseases in the "Guideline for pediatric transfusion", aiming to assist in the understanding and implementing the blood transfusion section of this guideline.
Humans
;
Child
;
Hematologic Diseases/therapy*
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic
10.Explanation and interpretation of the compilation of blood transfusion provisions for children undergoing hematopoietic stem cell transplantation in the national health standard "Guideline for pediatric transfusion".
Rong HUANG ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Ming-Yi ZHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Rong GUI ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(2):139-143
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion for children undergoing hematopoietic stem cell transplantation is highly complex and challenging. This guideline provides recommendations on transfusion thresholds and the selection of blood components for these children. This article presents the evidence and interpretation of the transfusion provisions for children undergoing hematopoietic stem cell transplantation, with the aim of enhancing the understanding and implementation of the "Guideline for pediatric transfusion".
Humans
;
Hematopoietic Stem Cell Transplantation
;
Child
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic

Result Analysis
Print
Save
E-mail