1.Pituitary Stalk Transection Syndrome
Journal of Korean Society of Endocrinology 1996;11(3):324-329
We experienced one case of severe pituitary dwarfism in a 16 years old male boy that magnetic resonance image(MRI) revealed transection of the pituitary stalk with the ectopic location of posterior pituitary gland and hypoplastic anterior pituitary gland. The serum growth horrnone(GH) response to clonidine and L-dopa revealed severe GH deficiency. The patient revealed normal response in TSH, prolactin and LH, FSH to TRH and LHRH respectively. So far, the primary cause of idiopathic pituitary dwarfism in many patients was due to hypoxic injury to hypothalmus by perinatal insults. In this patients, there was no history of perinatal insults and postnatal head trauma. We report a case of severe dwarfism due to hypogenesis of anterior pituitary gland.
Clonidine
;
Craniocerebral Trauma
;
Dwarfism
;
Dwarfism, Pituitary
;
Gonadotropin-Releasing Hormone
;
Humans
;
Levodopa
;
Male
;
Pituitary Gland
;
Pituitary Gland, Anterior
;
Pituitary Gland, Posterior
;
Prolactin
2.A study on the change of the lymphocyte subsets after splenectomy by flow cytometer.
Hoi Sang JEONG ; Baik Hwan CHO ; Yong HWANG
Journal of the Korean Surgical Society 1992;43(4):574-584
No abstract available.
Lymphocyte Subsets*
;
Lymphocytes*
;
Splenectomy*
3.Embolization of carotid-cavernous fistula using a silicone balloon and a tracker catheter system.
Sun Yong KIM ; Kil Ho CHO ; Bok Hwan PARK
Journal of the Korean Radiological Society 1992;28(1):36-41
With the recent introduction and development of the detachable balloon system, it has become the treatment of choice in the management of carotid cavernous fistulas(CCFs). But, since most delivery systems for embolization of CCF mainly depend on flow guidance for balloon delivery, in cases of small fistula, pseudoaneurysm and arterialized venous collaterals, failure of balloon embolization can occur. To overcome these limitations, the authors designed and used a new versatile, steerable, and flow-guided detachable balloon system by using a Tracker catheter system with silicone or latex balloons. Using this maneuver, we could get successful fistula occlusion in 7 out of 8 patients(silicone balloon). But in one case, we had to occlude the internal carotid artery at the fistula site, proximal and distal cervical portions of the internal carotid artery. This balloon delivery system proved to provide high selectivity for fistula and relatively ease of handing.
Aneurysm, False
;
Balloon Occlusion
;
Carotid Artery, Internal
;
Catheters*
;
Fistula*
;
Hand
;
Latex
;
Silicon*
;
Silicones*
5.The Surgical Approach for Direct Repair and Reconstruction on Posterior Cruciate Ligament Injury in the Knee Joint
Jin Hwan AHN ; Yong Girl LEE ; Hwang Keon CHO
The Journal of the Korean Orthopaedic Association 1988;23(4):1015-1019
The PCL is the strongest ligament in the knee joint. And it gives the posterior stability to the knee joint and act on rotation of knee joint. The many authors reported the surgical approaches for PCL. But none of them was satisfactory for exposure for PCL. Authors report the approach for repair and reconstruction on PCL injury The purpose of this report is to get the more satisfactory exposure of operation field for anatomical repair of injuried PCL. 1. PCL injury combined with MCL injury. a) MCL injury at its femoral attachment area. Detach the injuried MCL from femoral attachment completely, continue with anteromedial incision, and can observe both femoral and tibial attachment of PCL and ACL. b) MCL injury at its tibial attachment area. Retract the injuried MCL, medial meniscus, joint capsule superiorly, and through between medial meniscus and tibial proximal protion, also can observe the tivial attachment of PCL. 2. Isolated PCL injury. a) at tibial attachment(avulsion fracture) Through posterior approach or straight anteromedial approach, incised the posteromedial joint capsule, and can observed the tibial attachment of PCL. b) at substance level. Detach the MCL from its femoral attachment with bone-block and apply the knee valgus force. And can observe the entire length of PCL. Also reinforce the repaired site of PCL by reconstruction using a semitendinosus tendon.
Joint Capsule
;
Knee Joint
;
Knee
;
Ligaments
;
Menisci, Tibial
;
Posterior Cruciate Ligament
;
Tendons
6.The cervical spinal fractures : comparison of the sites and incidences according to the causes and the types of the injuries.
Jae Ho CHO ; Kil Ho CHO ; Woo Mock BYUN ; Sun Yong KIM ; Bok Hwan PARK
Yeungnam University Journal of Medicine 1993;10(1):114-126
The fractures of the cervical spine are relatively uncommon, but they may cause serious neurologic deficits temporarily or permanently. So, it is very important to treat the patients early by way of exact evaluation for the sites and the mechanisms of the injuries. The authors reviewed retrospectively 188 cervical spinal fractures in 100 patients from Sep. 1984 to Aug. 1990. Commonly involed levels were C5 and C6 in lower cervical level and C2 in upper cervical level and the sites in each spine were body; lamina and odontoid process. The hyperflexion injury was the most common type of the cervical spinal fractures occupying 53% of all cervical fractures and cause more multipe fractures(2.26 fractures/patient) than in hyperextension (1. 68 fractures/patient). In hyperflexion injuries, body, transverse and spinous process were commonly involved but lamina fracture was relatively common in hyperextension injury. The dislocations associated with fractures were developed most commonly in hyperflexion injury and 70% of these were anterior dislocation and the most commonly involved levels were C5-6 and C6-7. In conclusion, hyperflexion injury needs more close examination for the entire spinal levels than injuries of other mechanisms because it results in more severe fractures with or without dislocation and relatively frequent multiple fractures in different levels.
Dislocations
;
Humans
;
Incidence*
;
Neurologic Manifestations
;
Odontoid Process
;
Retrospective Studies
;
Spinal Fractures*
;
Spine
7.Detection of human CTLA-4 by using anti-peptide antibody.
Yong Hoon CHUNG ; Yang Ja CHO ; Seog Won LEEM ; Chang Hwan PARK ; Yong CHOI ; Dupont BO
Journal of the Korean Society for Microbiology 1993;28(3):229-237
No abstract available.
Humans*
8.Clinical observation for severed stensen's duct.
Han Yong KIM ; Hwan Ig KIM ; Byung San KIM ; Sam Yong LEE ; Bek Hyun CHO
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1991;18(2):256-264
No abstract available.
Salivary Ducts*
9.Treatment of Tibial Medial Bone Defect in Primary TKA.
Woo Shin CHO ; Key Yong KIM ; Soo Sung PARK ; Jung Hwan KIM ; Kwang Hwan JUNG ; Duck Hyun KIM
Journal of the Korean Knee Society 1999;11(1):13-19
There are several rnethods to correct the tibial bony defect including resection, cement filling, autograft or allograft and metal augmentation. The purpose of this study is to find the adequate treatment method of tibia bony defect through analysis of the result with above methods. From Sep. 1993 to Dec. 1997, the authors analyzed 93 cases of tibial medial bony defect corrected by overresection of lateral condyle, allograft and metal wedge or block among 358 cases of primary total knee arthroplasty(TKA) operated at Asan Medical Center. All cases were devided into four groups according to the treatment method; group A(31 cases) with overresection of lateral condyle, group B(37 cases) with metal wedge, group C(21 cases) with metal block and group D(4 cases) with allograft. The mean follow up period was 23.6 months(12 56 months). The results were as follows, 1. There were no definite statistical difference between group A, B, C and D in HSS knee score, ROM, correction of deformity. But in group D, there is one case of loss of the correction. 2. Loosening of the implant was not noted, but 17 cases of mild bony resorption was found just beneath the implant. It was particularly prominent in group B(9 cases) than group A(5 cases) and C(3 cases). 3. Among 4 cases of allograft, one has developed collapse of allograft. 4. 3 cases of deep infection developed only in group C, which were followed by revision TKA. Although further follow up study should be carried out, we concluded that resection of lateral tibial condyle, allograft, metal augmentation is a good substitute to the correction of the tibial bony defect in primary TKA.
Allografts
;
Autografts
;
Chungcheongnam-do
;
Congenital Abnormalities
;
Follow-Up Studies
;
Knee
;
Tibia
10.The Effect of Melatonin on Mouse Jejunal Crypt Cell Survival and Apoptosis.
Jin Oh KANG ; Eun Young HA ; Hyung Hwan BAIK ; Yong Ho CHO ; Seong Eon HONG
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2000;18(1):59-66
PURPOSE: To evaluate protective mechanism of melatonin against radiation damage and its relationship with apoptosis in mouse jejunum. MATERIALS AND METHODS:' 168 mice were divided into 28 groups according to radiation dose and melatonin treatment. To analysis crypt survival, microcolony survival assay was done according to Withers an (l Elkind's method. To analysis apoptosis, TUNEL assay was done according to Labet-Moleur's method. RESULTS: Radiation protection effect of melatonin was demonstrated by crypt survival assay and its effect was stronger in high radiation dose area. Apoptosis index with 8 Gy irradiation was 18.4% in control group and 16.5% in melatonin treated group. After 18 Gy, apoptosis index was 17.2% in control group and 15.4% in melatonin treated group. Apoptosis index did not show statistically significant difference between melatonin treated group and control group. CONCLUSION: Melatonin shows clear protective effect in mouse jejunum against radiation damage but it.', protective effect seems not to be related with apoptosis protection effect.
Animals
;
Apoptosis*
;
Cell Survival*
;
In Situ Nick-End Labeling
;
Jejunum
;
Melatonin*
;
Mice*
;
Radiation Protection