1.Evaluation the safety and efifcacy of corsair microcatheterin the recanalization for coronary chronic total occlusion with transradialantegrade approach
Lei GE ; Hao LU ; Yuxiang DAI ; Chenguang LI ; Qing QIN ; Jianying MA ; Yizhe WU ; Li SHEN ; Xiangfei WANG ; Qibing WANG ; Yan YAN ; Bing FAN ; Dong HUANG ; Kang YAO ; Feng ZHANG ; Juying QIAN ; Junbo GE
Chinese Journal of Interventional Cardiology 2014;(6):349-352
Objective The aim of this study was to evaluate the safety and efficacy of 135 cm Corsair microcatheter inpercutaneous coronary intervention (PCI) for coronary chronic total occlusion (CTO) with antegrade approach via radial artery. Methods From June 2010 to February 2014, a total of 81 patients with CTO lesions treated with 135cm Corsair microcatheter (Asahi Intec Co, Japan) and transradial antegrade approach was enrolled in this study. The success rate of CTO-PCI, the rate of Corsair microcatheter crossing the CTO lesions and the number of balloon catheters utilization were retrospectively analyzed. Unique complications related to the Corsair microcatheter were also documented. Results Success recanalization of CTO were achieved in 73 (90.1%) patients. Crossing the CTO body with Corsair microcatheter was found in 56(84.8%) patients. The number of balloon utilized after Corsair microcatheter crossing the CTO was much lower than that of patients who Corsair microcatheter failed to cross (1.3±0.6 per patient versus 2.8±1.2per patient, P < 0.05). The success recanalization rate of combined using Fielder XT guidewire with Corsair microcatheter was 51.5%. There was no complications related to Corsair microcatheter during the index procedure, no major adverse cardiac events during in-hospital clinical follow-up. Conclusions Corsair microcatheter was safe and effective in the recanalization for CTO with transradialantegrade approach. It can simplify the CTO-PCI procedure and reduce the number of balloon catheters.
2.Analysis of extreme obesity in two pedigrees due to leptin receptor mutation
Jingya YE ; Zhenzhen FU ; Wei GUAN ; Yizhe MA ; Yingyun GONG ; Shuai MA ; Xuan YE ; Chenxi ZHAO ; Xiaomei GENG ; Zhong LI ; Hui LIANG ; Hongwen ZHOU
Chinese Journal of Endocrinology and Metabolism 2019;35(1):32-36
This study reported two women with extreme obesity who underwent metabolic surgery due to their mutations in leptin receptor (LEPR).Genomic DNA was extracted from the anticoagulant blood samples of the two patients and their parents.A panel of genes related to metabolic diseases or whole exon sequencing was screened and the results were confirmed by Sanger sequencing.This is the first time that these three mutations in LEPR were reported.Two patients complained insatiety and early-onset obesity since childhood at clinics.Patient 1 was a 39-year-old woman with height 150 cm,weight 130 kg,and BMI 57.8 kg/m2.Serum leptin level was 156.4 μg/L.A homozygous mutation of c.2317G>T was found in exon 15 of LEPR gene in patient 1,which was descended from her father and mother respectively.Patient 2 was a 37-year-old woman with height 158 cm,weight 167 kg,and BMI 67 kg/m2.Serum leptin level was 193.4 μg/L.Genetic analysis showed compound heterozygous mutations of c.1482delT and c.1892C > A.Her father showed heterozygous c.1482delT mutation,and her mother carried heterozygous c.1892C > A mutation.Two patients all underwent metabolic surgery with body weight reduction of about 22 kg and 40 kg respectively after first six months.However,the follow-up studies showed that the body weight of patient 1 rebounded to pre-surgery level in two years and patient 2 did not further lose weight in the following six months.
3.Computer-aided design of an improved lamina hook and finite element analysis of its use in fixation of lumbar spondylolysis
Hongliang GAO ; Hua LIU ; Tao ZHANG ; Chengwei YANG ; Yizhe WANG ; Zirong HUANG ; Wenhua ZHANG ; Long CHEN ; Bing KANG ; Yuxuan MA ; Songkai LI
Chinese Journal of Trauma 2024;40(7):593-604
Objective:To design an improved lamina hook system and compare its biomechanical properties with traditional lamina hook system in fixation of lumbar spondylolysis.Methods:The thin layer CT data of the lumbosacral vertebrae of 20 healthy young male servicemen who underwent physical examination in the outpatient department of the 940th Hospital of Joint Logistics Support Force of PLA from January 2021 to August 2022 were collected. The age of the subjects was 20-30 years [(25.0±3.0)years]. A 3-dimensional model of the L 5 vertebral body was constructed using the 3-dimensional modeling software. The new improved lamina hook was designed according to the measurements including the thickness of the middle area, the longest longitudinal diameter, the curvature radius of the lower edge, the angle between the upper and lower tail ends, the thickness of the lower edge, and the longest diameter of the lower edge of the bilateral L 5 vertebral plates. One serviceman was selected from the aforementioned group to construct a linear finite element model of segments L 4-S using the 3-dimensional virtual software (normal model, model A), based on which, the L 5 bilateral spondylolysis model (model B), improved lamina hook model (model C) and traditional lamina hook models (model D) were designed. By constraining both sides of the sacrum and applying a longitudinal load of 400 N on the L 4 vertebral body, the upper 1/3 gravity of the body was simulated, and with a bending moment of 10 N·m along the X, Y, and Z directions, motions of forward flexion, backward extension, lateral bending, rotation, etc were simulated. The range of motion of segment L 4/5 and L 5/S 1 of model A was evaluated and compared with the findings of the previous researches to verify its effectiveness. The overall range of motion of models A, B, C, and D, the range of motion of segment L 4/5 and L 5/S 1, the maximum overall displacement, the maximum displacement and stress of the isthmus, the stress distribution and maximum stress of internal fixation of models C and D, and the stress distribution and maximum stress of the vertebral body of models C and D were compared. Results:(1) During forward flexion, backward extension, lateral bending and rotation, the range of motion of model A was 5.01°, 4.03°, 3.91° and 1.42° in segment L 4/5, and was 4.62°, 2.51°, 2.40° and 1.23° in segment L 5/S 1. (2) The overall range of motion, range of motion of segment L 4/5 and L 5/S 1 and maximum overall displacement of models A, C, and D were similar in axial compression, forward flexion, backward extension, left bending, and left rotation, while those of model B were significantly increased. (3) There was no significant difference in the maximum displacement of the isthmus of models A, C, and D under different motion modes, while the maximum displacement of model B in the isthmus was significantly larger than that of models A, C, and D, especially during rotation, increased by 295%, 277%, and 276% respectively. The maximum stress of the isthmus of model C was 0.938 MPa, 1.698 MPa, 0.410 MPa, 2.775 MPa, and 1.554 MPa respectively. The maximum stress in the isthmus of model D was 0.590 MPa, 1.297 MPa, 0.520 MPa, 3.088 MPa, and 2.072 MPa respectively. The maximum stress of the isthmus of models C and D was similar during axial compression and forward flexion, while the stress of the isthmus of model C was smaller than that of model D during backward extension, lateral bending, and rotation, decreased by 21.1%, 10.2%, and 25.0% respectively compared with model D. (4) The maximum stress of internal fixation in models C and D during forward flexion, backward extension, left bending, and left rotation was 135.220 MPa, 130.180 MPa, 200.940 MPa and 306.340 MPa respectively, and was 131.840 MPa, 112.280 MPa, 349.980 MPa and 370.140 MPa respectively. The maximum stress of internal fixation in the two models of internal fixation during forward flexion and backward extension was similar, while it was decreased by 42.6% and 17.2% in model C during left bending and left rotation, compared with model D. (5) The maximum stress of the vertebral body during forward flexion, backward extension, left bending, and left rotation was 79.787 MPa, 36.857 MPa, 37.943 MPa and 96.965 MPa respectively in model C, but was 80.104 MPa, 64.236 MPa, 196.010 MPa and 193.020 MPa respectively in model D. The maximum stress of models C and D was all distributed in the contact area with the internal fixation, and especially during backward extension, left bending, and left rotation, when it was reduced by 42.6%, 80.6%, and 49.8% of model C respectively, compared with that of model D. Conclusions:The improved laminar hook is more consistent with the Chinese anatomized structure of the lamina. Compared with the traditional lamina hook system, the improved lamina hook system can effectively reduce the displacement in all directions and range of motion of lumbar spondylolysis, therefor can significantly reduce the stress of internal fixation and vertebral body and has better biomechanical performance.