1.Effect of Xugu-Huoxue decoction for the patients with femoral neck fracture after internal fixation with hollow screw fixation
Yiyin HAN ; Fuchao SUN ; Xiangjun FAN ; Bo LIU
International Journal of Traditional Chinese Medicine 2017;39(3):204-207
Objective To evaluate effect of Xugu-Huoxue decoction on the treatment of patients with femoral neck fracture after internal fixation with hollow screw fixation. Methods A total of 120 patients with femoral neck fracture were randomly divided into the treatment group and the control group according to the inclusion criteria, 60 patients in each group. The control group was treated with cannulated screw internal fixation; the observation group was treated with Xugu-Huoxue decoction at the second day after the operation. Both groups were assessed with the Harris hip function score at the end of 12 months after operation. The SF-36 scale was used to evaluate the quality of life of the patients. Results The total effect rate of the observation group was 88.3% (53/60) and the control group was 71.7% (43/60). The difference between the 2 groups was statistically significant (χ2=5.208, P=0.022). At 12 months after surgery, the pain (41.4 ± 7.3 vs. 32.2 ± 5.7, t=7.738), the joint function (45.7 ± 6.2 vs. 36.3 ± 7.2, t=7.701), joint mobility (5.0 ± 0.8 vs. 3.1 ± 0.8, t=13.115), and the total score of Harris (87.7 ± 4.6 vs. 65.4 ± 5.4, t=24.461) in the observation group were significantly higher than those in the control group (P<0.001). The physical function (83.1 ± 7.2 vs. 78.8 ±14.2, t=2.095), body pain (82.1 ± 9.9 vs. 67.7 ± 11.1, t=7.524), the overall health (76.6 ± 10.3 vs. 68.8 ± 14.4, t=3.401) and activity (81.1 ± 7.9 vs. 76.6 ± 11.2, t=2.549) in the observation group were higher than those in the control group (P<0.05 or P<0.01). Conclusions The Xugu-Huoxue decoction could improve the prognosis of patients with femoral neck fractures after cannulated screw fixation, promote the recovery of hip function and improve the quality of life.
2.Therapeutic effect comparation between less invasive stabilization system plate and anatomical plate internal fixation for the treatment of tibial plateau fractures
Xiangjun FAN ; Yiyin HAN ; Fuchao SUN ; Nan ZHU
Chinese Journal of Postgraduates of Medicine 2016;39(12):1105-1108
Objective To observe the therapeutic effect between less invasive stabilization system (LISS) plate and anatomical plate internal fixation for the treatment of tibial plateau fractures. Methods The clinical data of 58 patients with tibial plateau fractures were retrospectively analyzed. The patients were divided into LISS plate group and anatomical plate group according to the internal fixation method with 29 cases each. The operative time, blood loss, incision length, fracture healing time, postoperative weight-bearing time, postoperative complications and therapeutic effect (according to Rasmussen knee joint function score scale) were compared between 2 groups. Results The operative time, incision length, blood loss and incidence of postoperative complications in LISS plate group were significantly lower than those in anatomical plate group:(68.5 ± 7.1) min vs. (92.3 ± 9.4) min, (5.8 ± 1.4) cm vs. (8.6 ± 2.1) cm, (208.5 ± 27.8) ml vs. (329.7 ± 25.2) ml and 17.2%(5/29) vs. 41.4%(12/29), and the excellent rate was significantly higher than that in anatomical plate group: 86.2% 25/29) vs. 62.1%(18/29), and there were statistical differences (P<0.05);there were no statistical differences in fracture healing time and postoperative weight-bearing time between 2 groups (P>0.05). Conclusions Both of LISS plate and anatomical plate internal fixation for the treatment of tibial plateau fractures have good clinical efficacy, but the LISS plate has advantages of shorter operation time, less tissue trauma, less blood loss, quicker fracture healing and less postoperative adverse reaction.