1.The appearance and clinical significance of persistent carotid-basilar artery anastomoses diagnosed by CT and MR angiography
Yipu MAO ; Longbai MA ; Tao HUANG
Journal of Practical Radiology 2015;(6):909-912
Objective To explore the appearance of CT angiography(CTA)and magnetic resonance angiography (MRA)in persis-tent carotid-basilar artery anastomoses,and discuss its clinical significance.Methods 1 7 patients of persistent carotid-basilar artery anastomoses diagnosed by CT and MR angiography were retrospectively reviewed.10 patients were examined by craniocervical CTA, 7 patients were examined by cranial and cervical MRA,and 3 patients were examined by CTA and MRA.Results 10 patients had persistent trigeminal arteries (PTA).Based on Saltzman type:6 cases were Saltzman type Ⅰ,2 cases were Saltzman typeⅡ,and 2 cases were Saltzman type Ⅲ.1 case of 3 persistent hypoglossal arteries(PHA)originated from the right carotid artery,and 2 cases originated from the left external carotid artery.2 cases of 4 proatlantal intersegmental artery(PIA)were right ipsilateral,and 2 cases were left ipsilateral.1 case of PTA and 1 case of PHA associated with an aneurysm.6 cases of PTA,2 cases of PHA and 1 case of PIA complicated with ipsilateral vertebral arteries artopied or hypoplasia of the contralateral vertebral artery.Conclusion CTA and MRA can demonstrate clearly the course of persistent carotid-basilar artery anastomoses and its complicating intracranial coexisting abnormalities.Diagnosis of this anatomic variation may be helpful for providing reliable data to the guidance of surgery and interven-tional treatment.
2.Value of 256-slice CTA for evaluation of coronary artery fistula
Yipu MAO ; Longbai MA ; Chuan LI ; Chaolong JIANG
Journal of Practical Radiology 2017;33(9):1416-1419
Objective To investigate the clinical value of 256-slice CT angiography (CTA) in diagnosing coronary artery fistula(CAF).Methods A total of 18 patients with CAF were analyzed retrospectively.The raw data were transferred to the work station.Image reconstruction techniques were employed, including multiplanar reconstruction (MPR),curved planar reconstruction (CPR),maximum intensity projection (MIP) and volume render (VR).Results Coronary artery angiography showed fistula affluxed to the pulmonary artery in 5 cases,affluxed to the coronary sinus in 5 cases,affluxed to the right atrium in 3 cases,affluxed to the left atrium in 3 cases, affluxed to the right ventricle in 2 cases.The blood flow from abnormal vessels to pulmonary arteries was demonstrated in 5 patients,and injection sign or hyper-density of contrast material in the main pulmonary artery was seen.The tortuous vascular networks on the surface of the main pulmonary artery trunk were seen in 2 cases.Formation of aneurysm was seen in 3 cases.Conclusion 256-slice CTA can precisely show the detailed anatomy variations and heomodynamic information of CAF, and directly display the abnormal vessels with multiple image reconstruction techniques.
3.The study of the correlation of middle meatus volume and maxillary fungal ball.
Haiyan LI ; Jianping LIANG ; Hong YUAN ; Yipu MAO
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2014;28(23):1860-1862
OBJECTIVE:
Observing the anatomic variation and measuring the bone volume of meatus and nasal cavity by analyzing the expression of paranasal sinus CT. Searching whether these variation and volume data are related to maxillary fungal ball.
METHOD:
Measuring the double side bone volume of middle meatus,nasal cavity and the rate of middle meatus volume in the same side of nasal cavity respectively in the normal group, the maxillary fungal ball group. Observing the anatomic variation and statistically evaluating the anatomic variation and volume of nasal cavity and nasal meatus.
RESULT:
In the maxillary fungal ball group, the affected side and the contralateral side volume of middle meatus,nasal cavity and the rate of middle meatus volume in the nasal cavity had no statistical difference (P>0.05); Comparing the middle meatus volume and the rate of middle meatus of the maxillary fungus ball group affected side and normal group,there was statistical difference (P<0. 05). In the maxillary fungal ball group and the normal group, the morbidity of deviation septum were 24. 24% and 33. 33%, the morbidity of OMC variation were 30. 3% and 26. 67% (P<0.05), the morbidity of nasal anatomic variation were 54. 55% and 60.00%, there was no statistical difference (P>0.05).
CONCLUSION
Maybe there is a correlation between the enlarged bone middle meatus and the maxillary fungal ball. There is no relationship between the nasal anatomic variation and the maxillary fungal ball.
Humans
;
Mycoses
;
etiology
;
Nasal Cavity
;
anatomy & histology
;
microbiology
;
Nasal Septum
;
Paranasal Sinuses
4.The value of dynamic contrast-enhanced MRI and diffusion tensor imaging in grading of glioma
Yipu MAO ; Longbai MA ; Wu HAN ; Yongta HUANG ; Haiming WEI
Journal of Practical Radiology 2017;33(2):190-193
Objective To explore the value of dynamic contrast-enhanced MRI (DCE-MRI)and diffusion tensor imaging(DTI)in grading of glioma.Methods 3.0T DCE-MRI and DTI scans were performed in 31 patients with glioma confirmed by pathology.Capacity volume transfer constant (Ktrans ),extravascular extracellular volume fraction (Ve ),exchange rate constant (Kep ),initial area under the gadolinium concentration-time curve (iAUC),and relative fractional anisotropy (rFA)were measured in the low grade glioma (LGG)and the high grade glioma (HGG).The correlation between parameters of DCE-MRI and rFA with microvessel denisity (MVD)and microvessel structure (MVS)were performed by Spearman rank correlation analysis.Results The MVD and MVS were positive correlation with the grading of glioma.Ktrans ,Kep ,Ve ,iAUC and rFA values of the LGG were (0.02±0.01)min-1 ,1.82 (0.18-8.54)min-1 ,0.05±0.03, 2.47±1.66 and 0.55±0.22,respectively.Ktrans ,Kep ,Ve ,iAUC and rFA values of the HGG were (0.1 1±0.02)min-1 ,1.31 (0.12-7.58)min-1 ,0.28±0.10,10.84 ±6.46 and 0.28 ±0.08,respectively.The differences of all parameters between the LGG and the HGG were statistically significant,except for Kep (P <0.05 ).Ktrans ,Ve and iAUC values were positive correlation with MVD and MVS (P <0.05),and rFA values were negative correlation with MVD and MVS (P <0.01).Conclusion The quantitative parameters of DCE-MRI and DTI have important values in grading of glioma and evaluating tumor angiogenesis and microvessel structure.
5.Application value of slice encoding for metal artifact correction-view angle tilting in chronic pain after total hip arthroplasty
Longquan HUANG ; Meihai XU ; Jieqin WEI ; Yipu MAO ; Wei SHEN ; Pingming LU ; Ai HE ; Yangyang PAN ; Dongmei FENG
Journal of Practical Radiology 2024;40(10):1707-1711
Objective To investigate the application value of slice encoding for metal artifact correction-view angle tilting(SEMAC-VAT)in chronic hip pain after total hip arthroplasty(THA).Methods A total of 22 patients who underwent TH A and required MRI reassessment for chronic hip pain were enrolled.All patients underwent coronal and axial short time inversion recovery(STIR)and SEMAC-VAT sequence scans.The prosthesis and surrounding artifact areas of STIR sequence and SEMAC-VAT sequence images were measured respectively.Likert scores were assigned to evaluate prosthesis clarity and visibility of surrounding anatomical structures.The number of abnormal lesions detected was recorded.Paired t-test and rank-sum test were used for comparisons between groups.Results Among the 22 patients,the mean prosthesis and surrounding artifact areas measured in coronal and axial STIR sequences were(73.08±11.28)cm2 and(34.36±8.47)cm2,respectively.For SEMAC-VAT sequences,the corresponding values were(44.30±8.41)cm2 and(23.08±5.85)cm2,respectively.These differences were statistically significant(t=13.942,8.659,P<0.05).SEMAC-VAT sequences had higher Likert scores on coronal and axial prosthesis clarity and surrounding anatomical structures visibility than STIR sequences(P<0.05).Additionally,SEMAC-VAT sequences were more effective in detecting abnormal lesions than STIR sequences(P<0.05).Conclusion Compared to STIR sequences,SEMAC-VAT sequences significantly reduce metal artifacts and enhance image quality in the assessment of chronic hip pain after THA.This technique is advantageous in detecting more positive signs,facilitating the evaluation of hip images in patients with chronic pain after TH A,and subsequently clarifying the etiology of pain.