1.Color Doppler ultrasonographic diagnosis of subacute thyroiditis
Li YANG ; Hongtao DUAN ; Yining SONG ; Shanshan ZHANG ; Xiaomin NIU ; Xue WANG ; Jianguo LI
Chinese Journal of Medical Imaging Technology 2009;25(12):2211-2213
Objective To assess the value of color Doppler ultrasonogarphy in the diagnosis of subacute thyroiditis (SAT). Methods Sixty-eight patients of SAT and 30 patients with thyroid papillary carcinoma were included, and their imaging features were retrospectively reviewed. Results All the patients with SAT had either focal or diffuse hypoechogenicity of the thyroid lobes with rich blood supplying in the diseased region, among them 52 patients (76.47%, 52/68) had tenderness on palpation. Diffuse and focal lesions were found in 40 (58.82%, 40/68) and 28 patients (41.18%, 28/68). The boundary and shape of focal lesions had no diagnostic characteristics compared with those of thyroid papillary carcinoma. Punctate calcification and resistance index (RI) in the nodule were significant different between the SAT and thyroid papillary carcinoma (P<0.05). Conclusion Color Doppler ultrasonography can display the features of SAT and is an effective method for the diagnosis of SAT.
2.Transfection of double gene co-expressing adenovirus vector into arthritis rats
Ping FAN ; Lan HE ; Zhiming HAO ; Dan PU ; Xiaohong LV ; Yining SUN ; Nan HU ; Yanhua WANG ; Xiaoming DING ; Yang LI ; Wujun XUE
Chinese Journal of Tissue Engineering Research 2015;(18):2825-2830
BACKGROUND:Abnormal activation of lymphocytes and nuclear factorκB-dependent non-specific inflammation are two major manifestations of joint damage in rheumatoid arthritis. Co-stimulatory signal CD40/CD40L is the dominant co-stimulatory factor in the recognition and activation of T cel s. IκBαeffectively inhibits nuclear factorκB pathway, prevent the inflammation in the central link, and suppress the damage caused by inflammatory factor in the synovial tissue.
OBJECTIVE:To investigate the therapeutic effect of double gene co-expressing adenovirus vector on arthritis based on an arthritis model rat transfected by CD40LIg-IRES2-IκBαco-expressing adenovirus vector.
METHODS:The pAdCD40LIg-IRES2-IκBαco-expressing adenovirus vector was established. Arthritic model was established through multi-subcutaneous injections of complete Freund's adjuvant of type col agen II (1 g/L) into Wistar rats. Then 20 arthritic rats were divided into two groups:untreated group and transfection group, receiving an injection of saline and pAdCD40LIg-IRES2-IκBαadenovirus vector to distal joint cavity of limbs, respectively.
RESULTS AND CONCLUSION:At 14 days post-transfection, compared with the untreated group, the mean arthritis index score, the CD40L expression of lymphocytes in synovial fluid, the nuclear factor-κB p65 expression in synovial tissue, and levels of interleukin-2, interleukin-6, tumor necrosis factor-α, matrix metal oproteinase-3 and matrix metal oproteinase-9 in synovial fluid of rats in transfection group were significantly lower than those in untreated group. Focal transfection of the CD40LIg-IκBαco-expression adenovirus vector can effectively inhibit arthritic symptoms, and reduce the expressions of inflammatory cytokine in synovial fluid and inflammatory molecule in synovial tissue of arthritic rats, which shows good therapeutic effect.
3.Chemical constituents from Callicarpa kwangtungensis and their hemostatic activities.
Shu-Tian XUE ; Wei LIU ; Tao YUAN
China Journal of Chinese Materia Medica 2023;48(14):3815-3825
This study aims to identify the chemical constituents from Callicarpa kwangtungensis and determine their activities. MCI, ODS, and Sephadex LH-20 chromatography and semi-preparative HPLC were employed to separate the chemical constituents. A total of 15 compounds were separated, and their structures were identified on the basis of spectroscopic analysis and comparison with the data in relevant literature. Specifically, the 15 compounds were 3-O-α-L-rhamnopyranosyl-6-O-β-D-apiofuranosyl-4-O-E-caffeoyl-D-glucopyranoside(1), 3,6-O-α-L-dirhamnopyranosyl-4-O-E-caffeoyl-D-glucopyranoside(2), β-OH-forsythoside B(3), β-OH-poliumoside(4),(+)-lyoniresinol-3α-O-β-D-apiofuranosyl-(1→2)-β-D-glucopyranoside(5),(+)-lyoniresinol-3α-O-β-D-glucopyranoside(6),(-)-lyoniresinol-3α-O-β-D-glucopyranoside(7), kelampayoside A(8), descaffeoylpoliumoside(9), acteoside(10), alyssonoside(11), poliumoside(12), isacteoside(13), acetyl forsythoside B(14), and forsythoside B(15). Compounds 1 and 2 were novel, and the NMR data of compounds 3 and 4 were reported here for the first time. Furthermore, the hemostatic activities of the extract and abundant ingredients(compounds 12 and 15) of C. kwangtungensis were determined with Yunnan Baiyao as the positive control and normal saline as the negative control. The extract and compounds 12 and 15 significantly shortened the tail tip bleeding time in mice.
Animals
;
Mice
;
Callicarpa
;
Hemostatics
;
China
;
Glycosides/chemistry*
4.Initial Experience of the Application of Third-generation Dual-source CT Scanner in High-pitch Angiography of Aorta.
Jixiang LIANG ; Lingyan KONG ; Zhengyu JIN ; Yun WANG ; Huadan XUE ; Yining WANG ; Daming ZHANG ; Jin CHEN
Acta Academiae Medicinae Sinicae 2017;39(1):68-73
Objective To evaluate the value of third-generation dual-source CT scanner in application of high-pitch aorta CT angiography(CTA). Methods Totally 59 patients clinically indicated for whole aorta angiography were divided into 2 groups using a simple random method:in group 1 there were 28 patients who underwent the examination on a third-generation dual-source CT device,with a collimation of 2×192×0.6 mm and a rotation time of 0.25 s;in group 2 there were 31 patients who underwent the examination on a second generation dual-source CT device,with a collimation of 2×128×0.6 mm and a rotation time of 0.28 s. Both groups were given the examination operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,a tube voltage of 100 kV,and automated tube current modulation using a reference tube current of 288 mA. A contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser in 5.0 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose(ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 19.44% lower (t=-3.989,P=0.000) in group 1 [(3.15±0.86)mSv] than in group 2 [(3.91±0.60)mSv]. These two groups showed no significant differences in SNR or CNR (all P >0.05). The subjective diagnostic quality values also showed no significant difference between two groups [(1.39±0.50)scores vs. (1.45±0.51)scores;W=814.5,P=0.651].Conclusion Compared with the second-generation dual-source CT scanner,the third-generation dual-source CT scanner in whole aorta CTA can remarkably reduce the radiation dose without affecting image quality.
Aorta
;
diagnostic imaging
;
Computed Tomography Angiography
;
methods
;
Humans
;
Radiation Dosage
;
Retrospective Studies
;
Signal-To-Noise Ratio
5.Initial Experience of the Application of Automated Tube Potential Selection Technique in High-pitch Dual-source CT Angiography of Whole Aorta Using Third-generation Dual-source CT Scanner.
Lingyan KONG ; Jixiang LIANG ; Huadan XUE ; Yining WANG ; Yun WANG ; Zhengyu JIN ; Daming ZHANG ; Jin CHEN
Acta Academiae Medicinae Sinicae 2017;39(1):62-67
Objective To evaluate the application of automated tube potential selection technique in high-pitch dual-source CT aortic angiography on a third-generation dual-source CT scanner. Methods Whole aorta angiography were indiated in 59 patients,who were divided into 2 groups using a simple random method:in group 1 there were 31 patients who underwent the examination with automated tube potential selection using a vascular setting with a preferred image quality of 288 mA/100 kV;in group 2 there were 28 patients who underwent the examination with a tube voltage of 100 kV and automated tube current modulation using a reference tube current of 288 mA. Both groups were scanned on a third generation dual-source CT device operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,collimation of 2×192×0.6 mm,and a rotation time of 0.25 s. Iterative reconstruction algorithm was used. For group 1,the volume and flow of contrast medium and chasing saline were adapted to the tube voltage. For group 2,a contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser at 5 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose (ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 21.3% lower (t=-3.099,P=0.000) in group 1 [(2.48±0.80) mSv] than in group 2 [(3.15±0.86) mSv]. Two groups showed no significant difference in attenuation,SD,SNR,or CNR at all evaluational parts of aorta (ascending aorta,aortic arch,diaphragmatic aorta,or iliac bifurcation)(all P>0.05). There was no significant difference in subjective diagnostic quality values of two groups [(1.41±0.50) scores vs. (1.39±0.50) scores;W=828.5,P=0.837]. Conclusion Compared with automated tube current modulation,the automated tube potential selection technique in aorta CT angiography on a third-generation dual-source CT can dramatically reduce radiation dose without affecting image quality.
Algorithms
;
Aorta
;
diagnostic imaging
;
Computed Tomography Angiography
;
methods
;
Humans
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
;
Signal-To-Noise Ratio
6.Primary pulmonary artery chondrosarcoma: the use of different imaging modalities.
Fengdan WANG ; Yining WANG ; Huadan XUE ; Yingqiang ZHANG ; Jian SUN ; Qi MIAO ; Yan ZHANG
Chinese Medical Journal 2014;127(15):2868-2869
7.Role and mechanism of caffeic acid in a mouse model of severe acute pancreatitis
Siyu XU ; Tao LIU ; Lulu LAN ; Yining XUE ; Wei WEI ; Yi HAN ; Sucheng MU ; Haiyan SONG ; Shilin DU
Journal of Clinical Hepatology 2025;41(4):722-730
ObjectiveTo investigate the effect and potential mechanism of caffeic acid (CA) on severe acute pancreatitis (SAP) induced by caerulein combined with lipopolysaccharide (LPS), and to provide a basis for the research on novel drugs for the treatment of SAP. MethodsC57BL/6J mice, aged 6 weeks, were divided into control group, model group, CA group, and octreotide acetate (OA) group, with 6 mice in each group. The mice in the control group were given injection of normal saline, and those in the other groups were given intraperitoneal injection of caerulein combined with LPS to establish a mouse model of SAP. At 1 hour after the first injection of caerulein, the mice in the CA group and the OA group were given intraperitoneal injection of CA or subcutaneous injection of OA at an interval of 8 hours. The general status of the mice was observed after 24 hours of modeling, and serum, pancreas, lung, and colon samples were collected. HE staining was used to observe the histopathological changes of the pancreas and lungs, and the serum levels of α-amylase, lipase, tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), alanine aminotransferase, aspartate aminotransferase, and creatinine were measured. RT-PCR was used to measure the expression of proinflammatory factors in the pancreas and lungs; myeloperoxidase (MPO) immunohistochemistry was used to observe the degree of neutrophil infiltration; Western blot was used to measure the activation of nuclear factor-kappa B (NF-κB) and the level of citrullinated histone H3 (CitH3), a marker for the formation of neutrophil extracellular traps (NETs), in the pancreas and lungs, as well as the expression level of ZO-1 in colon tissue. A one-way analysis of variance was used for comparison of continuous data between multiple groups, and the Dunnett’s t-test was used for further comparison between two groups. ResultsCompared with the control group, the model group had severe injury in the pancreas and lungs and significant increases in the activity of serum α- amylase and lipase and the levels of the proinflammatory cytokines IL-6, interleukin-1β (IL-1β), and TNF-α in serum and lung tissue (all P<0.05), as well as significant increases in NF-κB activation, neutrophil infiltration, and the formation of NETs in the pancreas and lungs (all P<0.05). Compared with the model group, the CA group had alleviated pathological injury of the pancreas and lungs and significant reductions in the activity of serum α-amylase and the levels of the proinflammatory cytokines IL-6, IL-1β, and TNF-α in serum and lung tissue (all P<0.05), as well as significant reductions in NF-κB activation, neutrophil infiltration, and the formation of NETs in the pancreas and lungs (all P<0.05). ConclusionCA can alleviate SAP induced by caerulein combined with LPS in mice, possibly by inhibiting neutrophil recruitment and the formation of NETs.
8.Nanoparticles with rough surface improve the therapeutic effect of photothermal immunotherapy against melanoma.
Jiao XUE ; Yining ZHU ; Shuting BAI ; Chunting HE ; Guangsheng DU ; Yuandong ZHANG ; Yao ZHONG ; Wenfei CHEN ; Hairui WANG ; Xun SUN
Acta Pharmaceutica Sinica B 2022;12(6):2934-2949
Photothermal therapy has been intensively investigated for treating cancer in recent years. However, the long-term therapeutic outcome remains unsatisfying due to the frequently occurred metastasis and recurrence. To address this challenge, immunotherapy has been combined with photothermal therapy to activate anti-tumor immunity and relieve the immunosuppressive microenvironment within tumor sites. Here, we engineered silica-based core‒shell nanoparticles (JQ-1@PSNs-R), in which silica cores were coated with the photothermal agent polydopamine, and a bromodomain-containing protein 4 (BRD4) inhibitor JQ-1 was loaded in the polydopamine layer to combine photothermal and immune therapy for tumor elimination. Importantly, to improve the therapeutic effect, we increased the surface roughness of the nanoparticles by hydrofluoric acid (HF) etching during the fabrication process, and found that the internalization of JQ-1@PSNs-R was significantly improved, leading to a strengthened photothermal killing effect as well as the increased intracellular delivery of JQ-1. In the animal studies, the multifunctional nanoparticles with rough surfaces effectively eradicated melanoma via photothermal therapy, successfully activated tumor-specific immune responses against residual tumor cells, and further prevented tumor metastasis and recurrence. Our results indicated that JQ-1@PSNs-R could serve as an innovative and effective strategy for combined cancer therapy.