1.Clinical value of intravascular ultrasound in diagnosing stent fracture: report of two cases with literature review
Journal of Interventional Radiology 2009;18(9):707-710
Stent fracture has been implicated as a cause of drug-eluting stent failure. The authors report here 2 cases with stent fractures which were diagnosed by coronary artery angiography and intravascular ultrasound (IVUS). Both of them received multiple-stent-implantation. Five stent fractures altogether were detected in two patients. All the involved stents were sirolimus-eluting ones. Angiographic study showed that three stent fractures were complete transverse linear fracture with stent displacement. IVUS demonstrated that three stent fractures were complete break and two were partial break. One fracture was located close to the overlapping site of two stents and another fracture was accompanied by the formation of a coronary aneurysm. Angiography and IVUS are helpful to identify stent fracture. In addition, IVUS is more likely to clarify the cause of stent failure as well as the mechanism of stent fracture.
2.Intravascular ultrasound assessment of the causes of coronary angiographic hazy lesions
Yingjia XU ; Weiyi FANG ; Xiangjun YANG
Clinical Medicine of China 2011;27(3):229-231
Objective To identify the causes of coronary angiographic hazy lesions by intravascular ultrasound (IVUS) to avoid inappropriate stenting. Methods Twenty-five cases with hazy regions on coronary angiogram were consecutively identified from July 2009 to March 2010. Hazy regions were defined by coronary arteriongraphy as reduced contrast density without a clearly defined intimal tear, dissection,thrombus,or stenosis ( > 50% ). This cohort of patients were subsequently underwent IVUS examinations and treated according to the results of IVUS. Results The lumen CSAs were settled as > 4. 0 mm2 in all examinations. Among all 25 cases,hazy lesions were located in left anterior descending in 12 patients, right coronary artery in 6 patients, left circumflex in 5 patients, and left main artery in 2 patients. According to the IVUS findings, 2 cases showed absolutely normal or near-normal arterial wall structure image, 10 cases showed calcified plaque,5 cases showed plaque rupture,3 cases showed eccentric plaque ,2 cases showed thrombosis formation,2cases showed dissection,1 case showed subintimal hematoma. Seven patients received stent implantation, and the rest accepted medical therapy. There were no in-hospital MACEs reported among all patients. Conclusion Nearly half of the coronary arteriongraphic hazy lesions were caused by calcified plaque. IVUS can distinguish calcified plaques from intimal tears, thrombus and other underlying etiologies,and help to avoid unnecessary stenting.
3.The effects of cisplatin on cancer stem cell markers of hepatocellular carcinoma cell line HepG2
Yingjia XU ; Yinjun XUE ; Chanjuan LU
International Journal of Laboratory Medicine 2016;37(8):1023-1025
Objective To observe the effects of cisplatin on the expression of tumor stem cell markers in human hepatoma cell line HepG2 .Methods The cultured human hepatoma HepG2 cells in logarithmic growth phase were used for the study ,which were divided into control(no special treatment was administrated) and experimental groups(cisplatin was added) ,then the rates of cell growth inhibition ,transitional healing rates and changes in tumor associated markers associated P53 ,caspase‐3 ,caspase‐8 ,CD133 ,a‐denosine triphosphate‐binding cassette superfamily G member 2(ABCG2) ,intercellular cell adhesion molecule‐1(ICAM‐1) were measured .Results Comparison of cell growth inhibition :with the increase of drug concentration increased ,compared with the con‐trol group ,the difference was statistically significant(P<0 .05) .Transitional healing rate:with the increase of drug concentration , compared with the control group ,the difference was statistically significant(P< 0 .05) .The expression of related tumor markers P53 ,caspase‐3 ,caspase‐8 increased while the drug concentrations increase and were higher in the control group(P< 0 .05) ,the difference were statistically significant .In the immunofluorescence for the detection of CD133 ,ABCG2 ,ICAM‐1 ,the fluorescence in‐tensity increased with the concentrations of cisplatin .Conclusion Cisplatin could inhibit the growth of tumor cells by up‐regulating the tumor markers such as P53 ,caspase‐3 and caspase‐8 .The migration of tumor cells in cell scratch test could also be inhibited by cisplatin w hile their drug resistance w ere enhanced .
4.A pilot study on efficacy and safety profile of a low clopidogrel maintenance dose following drug eluting stent implantation
Yingjia XU ; Tao WANG ; Weiyi FANG
Chinese Journal of Interventional Cardiology 2003;0(05):-
0.05).There were no statistical difference between the 50 mg IM group and the 75 mg NM group in secondary end-point.Conclusion Maintenance therapy with 50 mg domestic clopidogrel did not increase the 1-year incidence of major adverse cardiac events when compared with standard 75 mg of Plavix therapy.
5.Influence of MSCs Transplant on Ventricle Reconstruction in Mini Pig Model of Acute Myocardial Infarction
Yingjia XU ; Weihua WU ; Ritai HUANG ; Hongsheng ZHU
China Pharmacy 1991;0(06):-
OBJECTIVE: To study the influence of auto messenchymal stem cells(MSCs)transplant into the infracted area on the ventricle reconstruction in mini pig model of acute myocardial infarction. METHODS: The bone marrow of mini pig was collected and centrifuged in vitro for MSCs. Then after cultivation, transformation and labeling MSCs were injected into the ligated left anterior descending coronary artery and myocardium of mini pig,while the control group was administered with DMEM of the same dose. Doppler ultrasonography was performed separately at 3 weeks and 6 weeks. RESULTS: The left ventricular ejection fraction, shortening fraction, lateral thickening , and interventricular thickening in the experimental group were significantly improved, as compared with the control group, while the ventricular chamber in the experimental group was smaller than that in the control group. CONCLUSION: MSCs transplant can help to regenerate the myocardial issue in the infarcted area, thicken the myocardium, lessen the thinningz and cardiac muscle chamber, hence to slow down the process of ventricular reconstruction .
6.Research Achievements on Post-harvest Handling and Quality Control of Radix Paeoniae Alba
Ming KONG ; Yingjia BAI ; Jindi XU ; Min LU ; Xiaoning WANG ; Songlin LI
World Science and Technology-Modernization of Traditional Chinese Medicine 2014;(10):2248-2254
In present paper, research achievements of post-harvest handling concerning decorticating, boiling, sul-fur-fumigation, drying and sterilizing as well as quality control of Radix Paeoniae Alba were reviewed. Major prob-lems in the post-harvest handling and quality evaluation of Radix Paeoniae Alba were discussed. Strategies for im-provement in post-harvest handling and quality control were proposed, so that the safety and quality consistency can be assured in the medicinal application of Radix Paeoniae Alba.
7.Preoperative assessment of the accuracy of breast cancer size measured by two-dimensional ultrasound, three-dimensional volume ultrasound and ultrasound strain elastography and its influencing factors
Liling XIAO ; Yingjia LI ; Fei MA ; Mei YI ; Yang GAO ; Ziting XU
Chinese Journal of Ultrasonography 2021;30(5):414-419
Objective:To evaluate the accuracy of two-dimensional ultrasound(2D-US), three-dimensional volume ultrasound (3D-US) and ultrasound strain elastography (USE) in the measurement of preoperative tumor size of breast cancer and its influencing factors.Methods:A total of 101 patients with breast cancer in Nanfang Hospital of Southern Medical University from April to November 2016 were recruited in this study. The maximum diameter of the lesion was examined by 2D-US 3D-US and USE before core needle biopsy or surgery biopsy. The Bland-Altman analysis and intraclass correlation coefficient (ICC) were used to analyze the consistency between the ultrasonic technique measurements and the pathological measurements of postoperative lesion. Chi-square test or Fisher exact test was used to analyze whether the accuracy of three imaging techniques was affected by different clinical pathologic factors and imaging characteristics.Results:3D-US showed better agreement with histology than 2D-US and USE, with a higher ICC (ICC 3D-US=0.90>ICC 2D-US=0.81>ICC SUE=0.78) and low variation. In 3D-US, the accuracy rate of the age >40 years old group was higher than ≤40 years old group. In 2D-US, the measurement accuracy of invasive ductal carcinoma (IDC) without intraductal carcinoma in situ (DCIS) group was higher than DCIS with DCIS group, non-microcalcifications group was more accurate than microcalcifications group. The long diameter of lesion ≤2 cm group was more accurate than >2 cm group, IDC group was more accurate than invasive lobular carcinoma(ILC) group. In USE, the measurement accuracy of IDC without DCIS group was higher than DCIS with DCIS group, non-microcalcifications group was more accurate than microcalcifications group. All the differences mentioned above were statistically significant(all P<0.05). Conclusions:For accurate measurement of the size of breast cancer lesions, 3D-US is the best, which is least affected by clinicopathological factors and imaging features, followed by 2D-US and USE. This has certain significance for clinically determining the extent of breast cancer lesions.
8.Utility of 64-MSCT in assessing acute non-reperfused myocardial infarct size
Xinkai QU ; Weiyi FANG ; Jianding YE ; Shaofeng GUAN ; Ruogu LI ; Yingjia XU ; Yan SHEN ; Min ZHANG ; Hua LIU
Journal of Geriatric Cardiology 2013;(3):247-252
Objective To evaluate the utility of multi-slice computed tomography (MSCT) in assessing acute non-reperfused myocardial infarct size. Methods Seven domestic pigs (mean weight 17.3 ± 1.9 kg) underwent ligation of the distal left anterior descending artery to establish a model of acute myocardial infarction (MI). MSCT and triphenyltetrazolium chloride (TTC) staining were performed two hours later. The following data were acquired and analyzed:MI volume (%), CT values of the infarcted region, left ventricular cavity and normal cardiac tissue at various scanning time-points (1, 5, 10, 15, 20 min after contrast injection). Results Using MSCT, the overall MI volume showed a time-dependent decrease, with a reduction of 28.87%after 20 min. The greatest reduction occurred at the 5 min time-point. In TTC staining, MI volume was 9.87%± 2.44%. When MI size, as determined by MSCT, was compared with that by TTC staining in Bland-Altman plots, there was a better agreement at 5, 10, and 15 min time-points at 1 and 20 min. Conclusions The study indicates that double-phase scanning examination using MSCT is a useful tool to assess MI size, and the optimal late-phase scanning time-point set within 5-15 min of contrast injection.
9.Evaluation of conventional ultrasound in the detection of subclinical hemorrhage of hemophilia joint
Yaru ZHANG ; Hao LIU ; Fei MA ; Yang GAO ; Cong XU ; Mei YI ; Jing SUN ; Xiaoqin FENG ; Yingjia LI
Chinese Journal of Ultrasonography 2021;30(3):249-252
Objective:To explore the application value of conventional ultrasound(US) in detecting occult bleeding lesions in joints of patients with hemophilia.Methods:Twenty-seven children with severe hemophilia A who received factor Ⅷ prophylactic treatment from March 2017 to April 2018 in Nanfang Hospital, Southern Medical University were enrolled. Clinical data were collected from routine practice accompanied with US examination, hemophilia joint health score (HJHS) 2.1 assessment and the history of hemarthrosis of both ankles, elbows and knees at baseline and at 1 year follow-up.Results:A total of 157 joints of 27 patients were followed up for one year. During the treatments, 74 joints were found without history of hemarthrosis, among which the total US score of 14(14/74, 18.9%) joints increased, and HJHS 2.1 score of 11(11/74, 14.9%) joints developed. There was no significant change in the HJHS 2.1 score of 108 joints, among which 25 joints (25/108, 23.1%) had an increase in the total US score.However, there was no significant change in the total US score for 93 joints, of which 9(9/93, 9.7%) had an increase in HJHS 2.1 score.Conclusions:US examination can sensitively detect hemophilia arthropathy in joints without history of hemarthrosis and without obvious progression of arthropathy by HJHS 2.1 examination, and provide clinicians with more accurate joint information.
10.Status analysis and management reflection of the development of pediatric young scientists
Zhen WANG ; Wei LIU ; Shuang YIN ; Yingjia XU ; Jinyu LIU ; Qiongshu ZHAO ; Jun TAI ; Yang YU
Chinese Journal of Medical Science Research Management 2020;33(4):289-292
Objective:Through analysis of the development status of pediatric and the problems faced by pediatric young scientists, combined with the situation of research management, this paper puts forward some suggestions.Methods:Collect the identified problems of pediatric development, summarize the common ones and propose methodological strategies for scientific research management.Results:The development of pediatrics faces problems such as insufficient resources, unreasonable resource allocation and talents shortage.Conclusions:It is recommended to support the development of pediatric according to optimize the scientific research management model, establish a reasonable evaluation and incentive mechanism, establish a pediatric talent training model and team, improve the pediatric research level, and obtain policy support for salary, talent introduction and training, promotion of professional titles, research resources and so on.