1.Epidemiological characteristics analysis of tuberculosis among college students in Yangzhou during 2020-2024
Chinese Journal of School Health 2026;47(1):109-112
Objective:
To analyze the epidemiological characteristics of pulmonary tuberculosis (PTB) among college students in Yangzhou from 2020 to 2024, so as to provide a scientific basis for developing prevention and control strategies.
Methods:
An epidemiological investigation was conducted among 162 college students with PTB, and 7 134 of their contacts were screened. Data were obtained from the tuberculosis information management system and on campus screening records. Using descriptive epidemiological methods, trends in incidence, seasonal distribution, and bacteriological characteristics were analyzed.
Results:
From 2020 to 2024, the annual average incidence of pulmonary tuberculosis among college students in Yangzhou was 29.42 per 100 000, showing an overall fluctuating downward trend ( χ 2=12.36, P <0.01). Cases were mainly concentrated in summer and autumn, with the highest proportion in autumn (41.36%, 67/162), followed by summer (23.46%, 38/162). The proportion of etiologically positive cases increased from 37.21% in 2020 to 71.43% in 2024; among positive cases, the proportion of latent tuberculosis infection (LTBI) decreased from 66.67% (10/15) to 26.67% (4/15). The etiological positive rate was higher in females than in males ( χ 2= 11.76 , P <0.01). Comparison of screening methods showed that among index cases, the LTBI detection rate of the recombinant Mycobacterium tuberculosis fusion protein skin test (C-TST) was higher than that of the tuberculin skin test (TST), but the difference was not statistically significant ( χ 2=0.65, P =0.42); among close contacts, the detection rate of TST was higher than that of C-TST (15.1%,10.1%; χ 2=5.23, P <0.05).
Conclusion
From 2020 to 2024, the annual average incidence of pulmonary tuberculosis among college students in Yangzhou showed an overall fluctuating downward trend, with differences in TB infection screening methods and gender.
2.Application and regulatory challenges of organoid technology in medical field
Weilu CHENG ; Zehua WANG ; Yidan ZHANG ; Yinghui LIU
Chinese Journal of Tissue Engineering Research 2025;29(1):202-210
BACKGROUND:3D organoids have characteristics that resemble physiological tissues and to some extent mimic organ function,making them excellent models for applications ranging from basic development/stem cell research to personalized medicine. OBJECTIVE:To review and discuss the types of diseases and application areas such as tumor modeling that organoids can be applied to,as well as their regulatory status and challenges. METHODS:With"organoid,stem cell,disease model,3D printing technology,medical field"as Chinese and English search terms,we searched PubMed,Elsevier,WanFang,and CNKI databases to summarize and analyze organoid products at home and abroad,summarize the application of organoid technology in the medical field,and prospect the future development of organoid products in the medical field. RESULTS AND CONCLUSION:Organoids can break the limitations of traditional cell and animal models,avoid the ethical problems existing in clinical research,and have a high similarity to the source organ,a more similar performance to the physiology and pathology of human systems,and genetic stability,which has great advantages in current research.Organoids have been applied in the following fields:efficacy evaluation studies(preclinical models),including intestinal organoids,kidney organoids,liver organoids,gallbladder organoids,lung organoids,brain organoids,heart organoids,skin organoids,and reproductive system organoids;research on infectious diseases;cancer research and precision therapy;regenerative medicine;immune organoids.Although the United States,the European Union and China do not have perfect regulatory provisions,they are trying to promote the formulation of organoid regulatory laws and regulations.In China,although no organoid medical device products have been listed for the time being,its related regenerative medicine products have made breakthroughs.
3.Analysis of the correlation between the anatomical features of patent foramen ovale and right to left shunt
Yingying XU ; Yan SONG ; Hailan LIU ; Tingting LIU ; Yinghui CHEN ; Yanlin HE
China Modern Doctor 2024;62(9):66-70
Objective To investigate the correlation between the anatomical structure of patent foramen ovale(PFO)observed by transesophageal echocardiography(TEE)and the right to left shunt(RLS)grade of contrast-enhanced transthoracic echocardiography(c-TTE).Methods Ninety cases in which the presence of PFO was suggested by TEE examination as a diagnostic criterion from November 2021 to December 2022 in the First Hospital of Nanchang were retrospectively analysed.According to the c-TTE results of patients,the RLS was divided into 4 levels,and the correlation between PFO structural characteristics and RLS grading was analyzed.Results There was a positive correlation between PFO diameter size and RLS grading in resting state(r=0.381,P<0.05);The PFO diameter of patients with hypermobile interatrial septum(HIS)was larger and the difference was statistically significant(P<0.05);The PFO diameter of patients with persistent RLS was larger than that of excited phase patients,and the difference was statistically significant(P<0.05);There was no significant difference in RLS shunt degree between patients with long tunnel and those without long tunnel;There was no significant difference in RLS grade and PFO diameter size under Valsalva state.Conclusion Research has shown that certain anatomical structures of PFO interact with RLS grading,and PFO anatomical structures can also interact with each other(the opening diameter of the foramen ovale with HIS is larger);At the same time,TEE can clearly show the morphological characteristics of PFO and predict the degree of RLS,so as to further evaluate the possibility of ischemic stroke in patients with PFO,and provide more evidence for the indications for foramen ovale closure.
4.Effects of cognition-related lifestyles on early cognitive decline in community older adults in China
Haowei LI ; Shige QI ; Shengshu WANG ; Shanshan YANG ; Shimin CHEN ; Rongrong LI ; Xuehang LI ; Shaohua LIU ; Junhan YANG ; Huaihao LI ; Yinghui BAO ; Yueting SHI ; Zhihui WANG ; Yao HE ; Miao LIU
Chinese Journal of Epidemiology 2024;45(1):63-70
Objective:To investigate the distribution characteristics of cognition-related lifestyles of elderly in communities and explore the integrated effects on early cognitive decline.Methods:The participants were from the Project of Prevention and Intervention of Neurodegenerative Disease for Elderly in China. A total of 2 537 older adults aged ≥60 years without dementia in the 2015 baseline survey and the 2017 follow-up survey were included. The information about their cognition-related lifestyles, including physical exercise, social interaction, leisure activity, sleep quality, smoking status, and alcohol consumption, were collected through questionnaire survey and the integrated scores were calculated. Multivariate logistic regression analysis was used to assess the association between integrated cognition-related lifestyle score and early cognitive decline.Results:In the 2 537 older adults surveyed, 28.7% had score of 5-6, while only 4.8% had high scores for all 6 healthy lifestyles. Significant differences in healthy lifestyle factor distributions were observed between men and women. Multivariate logistic regression model showed that the risks for early cognitive decline in the older adults who had lifestyle score of 4 and 5-6 were lower than that in those with lifestyle score of 0-3 ( OR=0.683, 95% CI: 0.457-1.019; OR=0.623, 95% CI: 0.398-0.976; trend P=0.030). In the women, the risks for early cognitive decline was lower in groups with score of 4 and 5-6 than in group with score of 0-3 ( OR=0.491, 95% CI: 0.297-0.812; OR=0.556, 95% CI: 0.332-0.929; trend P=0.024). Conclusion:Cognition-related healthy lifestyles are associated with significantly lower risk for early cognitive decline in the elderly, especially in women.
5.Clinical application of additive manufacturing technology
Chinese Journal of Tissue Engineering Research 2024;28(17):2782-2788
BACKGROUND:Additive manufacturing technology provides strong technical support for personalized and precise medical treatment due to its rapid prototyping,digitalization,and personalization.Therefore,its medical devices have developed rapidly in orthopedics,oral,preoperative planning,craniomaxillofacial,and other clinical applications. OBJECTIVE:To briefly introduce the progress of additive manufacturing technology and its commercial application in the clinic in and outside China. METHODS:Wanfang Data,China National Knowledge Infrastructure(CNKI),PubMed,Elsevier,Springer Link databases,and the websites of National Medical Products Administration and FDA were searched using"additive manufacturing,medical device,clinical application,3D printing"as Chinese search terms and"additive manufacturing(AM),additive manufacturing technology,medical device,clinical application,3D printing"as English search terms.The search time ranged from January 2010 to March 2023,and a few classical long-term articles were included. RESULTS AND CONCLUSION:Additive manufacturing technology is classified by the form of raw materials(liquid-based,solid-based,and powder-based).At present,there are seven kinds of additive manufacturing processes,including fused deposition molding,stereo-curing molding,powder bed melting,directed energy deposition,binder jet 3D printing,inkjet printing,and layered solid manufacturing.The marketed additive manufacturing products include orthopedic products,dental products,preoperative planning guide plate/bone model products,and craniomaxillofacial products.The orthopedic products include matching long-segment bone defect restoration,interbody fusion cage,knee joint orthosis,vertebral prosthesis,thoracolumbar fusion matching prosthesis system,knee prosthesis,and hip prosthesis.Dental products include light-curing resin for additive manufacturing and BB Base 3D Printing Resin for Denture Base.The products of preoperative planning guide plates/bone models include bone models,medical orthopedic surgical guide plates,customized dental implant guide plates,and human organ models.The craniomaxillofacial products include polycaprolactone scaffolds,patient-specific skull implants,OsteoFab patient-specific face device,SpinFab VBR prosthesis,and TruMatch CMF titanium alloy 3D printing prosthesis system.
6.Methodology of Scientific, Transparent and Applicable Rankings for Chinese Guidelines and Consensus Related Literature Published in the Medical Journals: ample Identification and Speciality Assignment
Hui LIU ; Nan YANG ; Qianling SHI ; Xufei LUO ; Hairong ZHANG ; Jinhui TIAN ; Yinghui JIN ; Yaolong CHEN ; METHODOLOGY AND TECHNOLOGY SPECIALISATION COMMITTEE OF THE STAR WORKING GROUP
Medical Journal of Peking Union Medical College Hospital 2024;15(2):429-434
With the development of the Scientific, Transparent and Applicable Rankings tool for clinical practice guidelines(STAR), the publication of evaluation and ranking for scientificity, transparency and applicability of Chinese guidelines and consensus published in the medical journals in 2021and 2022, as well as the publication of the STAR evaluation and ranking for some specialities, the STAR evaluation and ranking has received widespread attention in the medical community. In order to further enhance its scientificity and transparency, Methodology and Technology Specialization Committee of the STAR Working Group presents this article to introduce sample identification and speciality assignment in the evaluation and ranking process.
7.Effects of acute normovolemic hemodilution on target-controlled infusion of etomidate blood concen-trations and adrenocortical function
Yinghui CUI ; Jiaming XU ; Tong LIU ; Haiyong TAO ; Xi-Aoyi XIE ; Shejun HU ; Xuefei WANG ; Jinghuo WANG ; Jianrong GUO
The Journal of Clinical Anesthesiology 2024;40(8):814-819
Objective To observe the effects of acute normovolemic hemodilution(ANH)on target-controlled infusion(TCI)of etomidate blood drug concentration and adrenal cortical function.Methods Sixty patients who undergo elective multisegmental spine surgery,35 males and 25 females,aged 30-60 years,BMI 20-25 kg/m2,ASA physical status Ⅰ or Ⅱ,were divided into two groups using random number table method:ANH group and control group,30 patients in each group.Both groups used a target-controlled infusion of etomidate for anesthesia induction and anesthesia maintenance.In the ANH group,ANH was performed after steady anesthesia induction,ideal Hct 28%to 30%,and transfused within 1 hour after surgery;the control group was routinely treated.The dosage of etomidate was recorded.Liquid chroma-tography-tandem mass spectrometry(LC-MS/MS)was used to detect etomidate blood concentrations at the immediate postoperative,10,20,and 30 minutes postoperative periods in the two groups,and the immedi-ate moment autologous blood collected into the storage bag,preserved in the storage bag for 1 hour,and the immediate moment transfused back in the ANH group.Plasma concentrations of cortisol(Cor),adrenocorti-cotropic hormone(ACTH),and aldosterone(ALD)were measured by chemiluminescence immunoassay(CLIA)before the induction of anesthesia,immediately after the operation,and at 1 day and 2 days postop-eratively.Results There was no significant difference in the total dosage of etomidate between the two groups.Compared with the immediate postoperative period,the plasma etomidate concentration was signifi-cantly decreased 10,20,and 30 minutes after surgery(P<0.05).Compared with the control group,the concentration increased significantly 10 minutes after surgery in the ANH group(P<0.05).The plasma concentrations of etomidate were(547.8±119.4)ng/ml at the immediate moment autologous blood collected into the storage bag,(536.7±107.8)ng/ml at the preserved in the storage bag for 1 hour,and(522.8±91.7)ng/ml at theimmediatemoment transfusedbackinthe ANHgroup.Comparedwithbeforein-duction of anesthesia,the concentration of Cor and ALD immediately after the operation decreased signifi-cantly(P<0.05)and the concentration of ACTH was significantly higher(P<0.05).There were no sta-tistically significant differences in the concentrations of Cor,ALD,and ACTH between the two groups before induction of anesthesia 1 day and 2 days postoperatively.Conclusion In the orthopedic surgery of TCI eto-midate,return transfusion of collected autologous blood transiently(about 10 minutes)increases etomidate blood concentrations,the function of adrenal cortical will recover to the preoperative level within 24 hours after the operation.
8.Clinical characteristics of eosinophilic lung diseases in children
Xiaolei XU ; Ju YIN ; Jun LIU ; Xiuyun LIU ; Yinghui HU ; Huiqing SHEN ; Guoli WANG ; Jing ZHANG ; Rui ZHANG ; Yan SU ; Runhui WU ; Baoping XU
Chinese Journal of Applied Clinical Pediatrics 2024;39(6):433-439
Objective:To analyze the clinical characteristics of eosinophilic lung diseases(ELD) in children to enhance pediatricians′ understanding of ELD.Methods:In this retrospective cross-sectional study, a total of 149 children with ELD were recruited from Beijing Children′s Hospital, Capital Medical University between April 1, 2007 and March 31, 2022.Chi-square test, Fisher′s exact test, Mann-Whitney U test and Kruskal-Wallis test were used to analyze data and conclude clinical characteristics.Spearman correlation was used to analyze the correlation between eosinophils in peripheral blood and bronchoalveolar lavage fluid.Chi-square test and Kappa consistency test were used to compare the differences and consistency in diagnostic results between bronchoalveolar lavage fluid or lung biopsy and eosinophil elevation with chest imaging abnormalities. Results:(1)The isolated lung involvement was mostly caused by allergic bronchopulmonary aspergillosis(9 patients), and other system involvement by idiopathic hypereosinophilic syndrome(89 patients).(2)The main respiratory manifestations included coughing(90 cases, 60.4%) and expectoration(41 cases, 27.5%), while 23.5%(35 cases) of patients had no respiratory symptoms; 50.3% had digestive system involvement, and 40.9% had skin involvement.These were the two most commonly affected organs.(3)Spearman correlation was performed between eosinophils in peripheral blood and bronchoalveolar lavage fluid( r=0.3, P<0.05).Chi-square test was performed to compare ELD diagnosed by bronchoalveolar lavage fluid or lung biopsy with peripheral blood eosinophilia accompanied by abnormal chest imaging( P<0.05).Kappa consistency test(Kappa<0.2) showed poor consistency between the two diagnostic methods. Conclusions:ELD are present in children, and multiple etiologies may be pathogenic.Among children with ELD, the isolated lung involvement is mainly caused by allergic bronchopulmonary aspergillosis.The digestive system and skin are the most commonly affected organs, except for lungs.The correlation between eosinophil levels in peripheral blood and bronchoalveolar lavage fluid is poor.
9.Development of a Traditional Chinese Medicine syndrome diagnosis scale for long-term simulated weightlessness experiments
Hongzhi SHI ; Chong XU ; Jiatuo XU ; Quanchun FAN ; Junlian LIU ; Liping TU ; Xiaojuan HU ; Chengpu ZHANG ; Shuang ZHAO ; Tao MI ; Yongzhi LI ; Yinghui LI
Space Medicine & Medical Engineering 2024;35(1):8-14
Objective To develop a Traditional Chinese Medicine(TCM)syndrome diagnosis scale suitable for evaluating the overall health status of participants in long-term simulated weightlessness experiments,and preliminarily evaluate its reliability and validity.Methods Based on the understanding of the pathogenesis of TCM in different stages of long-term manned spaceflight,a scale was developed through literature research and expert consultation.Test-retest reliability and internal consistency coefficient were used to test the reliability of the scale.Item analysis and factor principal component analysis were used to evaluate the validity of the scale,and a rotating component matrix was used to analyze the correlation between each item and dimension using 36 volunteers in a 90 days head down bed rest experiment as the research subjects.Results The scale contains eight dimensions and 57 items.The reliability analysis showed that the correlation coefficient of the total score of the scale for the first and second tests of 30 participants was 0.889,indicating high stability of the scale.The Cronbach coefficient of the scale was 0.934,indicating very good internal consistency.The split half reliability after correction was 0.858,indicating a high reliability of the scale.The validity analysis showed that the difference between the high score group and the low score one for each of the 57 items was statistically significant(P<0.01),and the Pearson correlation coefficient between each item and the total score of the scale was greater than 0.4(P<0.001).The cumulative contribution rate of 8 common factors extracted using principal component factor analysis was 55.293%,and the results of rotating component matrix analysis,after applying TCM theory and expert feedback,had a coincidence of up to 87.5%with the initial 8 dimensions,indicating good structural validity of the scale.Conclusion The scale has good reliability and validity,and can diagnose TCM syndromes.It is suitable for long-term simulated weightlessness experiment and provides an objective and quantitative new method for evaluating the subjective feelings of participants.
10.Research on the application of non-contact physiological and psychological detection in the analysis of long-term simulated weightlessness effects
Shuai DING ; Zi XU ; Qian RONG ; Shujuan LIU ; Zihao LIU ; Yuan WU ; Yao YU ; Zhili LI ; Cheng SONG ; Lina QU ; Hao WANG ; Yinghui LI
Space Medicine & Medical Engineering 2024;35(2):78-83,98
Objective Explore a non-contact physiological and psychological detection model based on facial video in simulations of weightlessness effects,research new methods for non-contact heart rate and negative mood state detection in long-term simulations of weightlessness effect analysis.Methods Construct a non-contact physiological and psychological data collection system for fusion analysis of visible light and thermal infrared videos.Collect physiological and psychological data of volunteers in the"Earth Star-Ⅱ"90-day head-down bed rest experiment.A non-contact heart rate detection model based on GCN facial multi-region feature fusion and a non-contact negative mood state detection model considering data reliability were constructed,and the effectiveness of the models were validated with finger clip heart rate and POMS-SF scale as labels.Results The experimental results show that the average difference in the Bland-Altman plot of the non-contact heart rate detection model is-1.26 bpm,and 96.3%of value error detection data falls within the 95%confidence interval,indicating a high consistency between the model detected heart rate and the finger clip heart rate.The non-contact negative mood state detection model achieves an accuracy of>0.85 for detecting tension,depression,anger,and fatigue.Features such as heart rate,AU06,eye gaze,and head pose were observed to be important to mood state detection.Conclusion Non-contact physiological and psychological detection methods not only can be utilized for long-term physiological analysis in simulations of weightlessness effects,but also provide a novel technical approach for on-orbit astronauts health assurance during long-term space flight in the future.


Result Analysis
Print
Save
E-mail