1.Stratified random sampling survey on senile chronic kidney diseases among elderly people aged over a certain Crops
Xue SONG ; Wenli WU ; Jiang CHENG ; Min GE ; Xinhong LU ; Zhaohui DENG ; Mengjie LIANG ; Yingbo SONG ; Ye ZHANG ; Weidong YI ; Xueli LIANG ; Shuang LIU ; Lei WANG ; Yan LI ; Xin ZHANG
Chongqing Medicine 2016;45(10):1360-1363,1366
Objective To understand the prevalence rate and related factors of chronic kidney disease (CKD) among elderly people aged more than 65 years old in the 66th regiment of the fourth division of A Crops in Xinjiang .Methods A total of 2 030 elderly people aged more than 65 years old in the 66th regiment of the fourth division of XPCC were distributed in 6 communities . Totally 334 permanent residents aged more than 65 years old were chosen from 2 communities by the stratified random sampling method .The renal injury indicators and related factors were detected .Results Among 329 residents with intact data ,after the age correction ,the prevalence rate of albuminuria ,hematuria and renal function decrease were 22 .2% ,14 .2% ,4 .9% ,respectively .The prevalence rate of CKD in this group was 32 .8% ,CKD stage 1―3 were dominated .The awareness rate was 15 .1% .The multiva‐riate Logistic regression analysis showed that gender and hypertension were independently associated with CKD .Conclusion The prevalence rate of CKD among elderly people aged over 65 years old in the 66th regiment of the fourth division of this Crops is high‐er .The related factors are gender and hypertension .
2.Comparative analysis on detection results of 4 items of liver enzymology in 11 clinical laboratories of Xinjiang Production and Construction Corps
Yingbo SONG ; Mengjie LIANG ; Xinhong LU ; Zhaohui DENG ; Jiang CHEN ; Wei GUO ; Liang WU ; Tianmei GONG ; Wenli WU ; Hongmei LI ; Chun SU ; Shisong WANG ; Qian YANG ; Xin ZHANG
International Journal of Laboratory Medicine 2018;39(11):1289-1292,1296
Objective To understand the comparability of the detection results of four items (ALT ,AST , GGT ,ALP) of liver enzymology in 11 clinical laboratories in Xinjiang Production and Construction Corps (XPCC) and offer reference for improving mutual recognition of the results .Methods Eleven clinical labora-tories of XPCC organized the result comparability tests of 4 items of liver enzymology twice in 2017 ,and the samples with 5 batches were completed in each comparability test .One set of detection system in each labora-tory was used as comparability system according to comparability scheme .The detection results were analyzed through Robust Z Score and the evaluation criterion was :|Z|≤2 "satisfied";2< |Z|<3"warning";|Z|≥3 "not satisfied".Results The detection results of all 10 batch samples in 4 clinical laboratories showed |Z|≤2 in 2 comparability tests .In the first comparability test ,the detection results of 5 batch samples for 4 items were |Z|≤2 in 5 laboratories .In the second comparability test ,the detection results of 5 batch samples for 4 i-tems were |Z|≤2 in 8 laboratories ,but the ALT results of 5 batch samples in 1 laboratory showed positive deviation(Z≥3)and the GGT results of 5 batch samples in the other laboratory showed negative deviation (Z≤ -3) .Conclusion The 11 clinical laboratories in XPCC should continuously improve quality management system and make sure that the mutual recognition of the detection results of 4 items of liver enzymology is effective .
3.The effects of repeated high acceleration on implant osseointegration in SD rats
Xiaoni ZHOU ; Xiangdong LIU ; Yingbo JI ; Shuai HUANG ; Yingliang SONG ; Wei MA
Journal of Practical Stomatology 2024;40(2):204-209
Objective:To investigate the effects of repeated high acceleration(+Gz)on implant osseointegration in SD rats.Methods:18 SD rats were divided into+Gz and control groups randomly(n=9),and 1 implant was placed in each femur of the rat's lower limb.24 hours postoperatively,the experimental rats were exposed to+Gz of 4 to 9 G with 1 G/s environment 3 times a week,while the con-trol rats were fed normally.3 rats from each of the 2 groups were sacrificed at 2,4 and 8 weeks after implantation.Micro-CT,sequential fluorescence double labeling,and histological examination were perfomed for the analysis of implant osseointegration.Results:The bone volume fraction(BV/TV),trabecular number(Tb.N),mineral apposition rate(MAR),implant-bone contact rate(BIC)and bone area in implant thread(BA)of the+Gz group were significantly lower than those of the control group at 2 weeks(P<0.05),and so as to MAR,BA at 4 weeks(P<0.05),while there was no significant difference of the parameters at 8 weeks after implantation.Conclusion:In SD rats early exposure to+Gz environment postoperatively may have a negative effect on initial osseointegration by slowing bone forma-tion.However,it will not lead to poorer bone mass when sustained over a long period.