1.Clinical observation on treatment of snake bite induced disseminated intravascular coagulation by qinwen baidu decoction.
Ying-nian MIAO ; Mao-chao CHEN ; Zhi HUANG
Chinese Journal of Integrated Traditional and Western Medicine 2003;23(8):590-592
OBJECTIVETo observe the effect of Qinwen Baidu Decoction (QBD) in treating snake bite induced dissseminated intravascular coagulation (DIC).
METHODSForty-six patients were randomly divided into the control group (n = 16) and the treated group (n = 30). They were all treated with the conventional therapy, including application of anti-snake venom serum and supplement of blood agglutination factors. For the treated group, QBD was administered additionally. The efficacy of treatment, chief indexes for DIC (platelet, fibrinogen and prothrombin time) and their recovery time, etc. were observed.
RESULTSThe total effective rate of the treated group was 93.33%, which was higher than that of the control group (56.35%), and the recovery time of chief DIC indexes in the treated group was significantly shorter than that in the control group respectively (P < 0.01).
CONCLUSIONQBD shows obvious effects of shortening therapeutic course and enhancing efficacy in treating snake bite induced DIC.
Adolescent ; Adult ; Combined Modality Therapy ; Disseminated Intravascular Coagulation ; drug therapy ; etiology ; Drugs, Chinese Herbal ; therapeutic use ; Female ; Humans ; Immune Sera ; Male ; Middle Aged ; Phytotherapy ; Single-Blind Method ; Snake Bites ; complications ; drug therapy ; Snake Venoms ; immunology
2.Differential gene expression of liver carcinoma cell after transfection of by ARL-1 with microarray.
Da-nian TANG ; Yong-guo LI ; Jun-min WEI ; Xiang-dong YANG ; Min-wei ZHU ; Pei WU ; Xiong-ying MIAO
Chinese Journal of Surgery 2003;41(3):180-182
OBJECTIVETo study the difference of the gene expression profile and to identify the different expression after transfection of the ARL-1 gene.
METHODSThe cDNA probes were synthesized from total RNA of study group and control group, which was differentially hybridized to cDNA chips and confirmed by a gene specific semiquantitative reverse transcription polymerase chain reaction (RT-PCR).
RESULTSSix kinds of gene expression were increased and 9 kinds of gene expression were decreased. The findings were correlated with protein metabolism, signal pathway, metastasis, and drug resistance.
CONCLUSIONScDNA chips showed that gene expression profile of liver carcinoma cell was changed after transfection of the ARL-1 gene. It is a useful method in understanding the mechanism of drug resistance.
Aldehyde Reductase ; genetics ; Drug Resistance, Neoplasm ; Gene Expression Profiling ; Humans ; Liver Neoplasms ; drug therapy ; genetics ; Oligonucleotide Array Sequence Analysis ; Transfection
3.Beneficial effects of natural Jeju groundwaters on lipid metabolism in high-fat diet-induced hyperlipidemic rats.
Yan Chao WANG ; Jin Miao LU ; Hui Zi JIN ; Ai Niu MA ; Jin Yang ZHANG ; Nian GONG ; Qi XIAO ; Bin ZHU ; Ying Fang LV ; Na YU ; Wei Dong ZHANG ; Yong Xiang WANG
Nutrition Research and Practice 2014;8(2):165-171
BACKGROUND: Groundwater is believed to possess many beneficial effects due to its natural source of various minerals. In this study, we examined the effects of natural Jeju groundwater S1 (Samdasoo(TM)), S2 and S3 pumped up from different locations of Jeju Island, Korea, along with local tap water, on body weight gain, serum lipids and lipoproteins, and liver histopathology in high-fat diet-induced hyperlipidemic rats. MATERIALS/METHODS: Rats were randomly and equally divided into 6 groups. Different water samples were supplied to the hyperlipidemic rats as their daily drinking water and the widely-used anti-hyperlipidemic drug simvastatin was used as a positive control. Body weight, serum lipids and lipoproteins were measured weekly. Liver weight, liver index and liver histopathology were examined after the execution of the rats. RESULTS: After drinking Jeju groundwaters for two months, S2 but not S3 significantly reduced weight growth and serum triglycerides levels and increased high density lipoprotein-C (HDL-C) without affecting total cholesterol or LDL-C. S1 and particularly S2 significantly reduced the severity of liver hypertrophy and steatosis. All Groundwaters had much higher contents of vanadium (S3>S2>S1>>tap water) whereas S1 and S2 but not S3 markedly blocked autoxidation of ferrous ions. CONCLUSION: Jeju Groundwater S1 and particularly S2 exhibit protective effects against hyperlipidemia and fatty liver and hypothesize that the beneficial effect of Jeju Groundwaters may be contributed from blockade of autoxidation of ferrous ions rather than their high contents of vanadium.
Animals
;
Body Weight
;
Cholesterol
;
Drinking
;
Drinking Water
;
Fatty Liver
;
Groundwater*
;
Hyperlipidemias
;
Hypertrophy
;
Ions
;
Korea
;
Lipid Metabolism*
;
Lipoproteins
;
Liver
;
Minerals
;
Rats*
;
Simvastatin
;
Triglycerides
;
Vanadium
;
Water
4.Prevalence, awareness, treatment, and control of hypertension in the non-dialysis chronic kidney disease patients.
Ying ZHENG ; Guang-Yan CAI ; Xiang-Mei CHEN ; Ping FU ; Jiang-Hua CHEN ; Xiao-Qiang DING ; Xue-Qing YU ; Hong-Li LIN ; Jian LIU ; Ru-Juan XIE ; Li-Ning WANG ; Zhao-Hui NI ; Fu-You LIU ; Ai-Ping YIN ; Chang-Ying XING ; Li WANG ; Wei SHI ; Jian-She LIU ; Ya-Ni HE ; Guo-Hua DING ; Wen-Ge LI ; Guang-Li WU ; Li-Ning MIAO ; Nan CHEN ; Zhen SU ; Chang-Lin MEI ; Jiu-Yang ZHAO ; Yong GU ; Yun-Kai BAI ; Hui-Min LUO ; Shan LIN ; Meng-Hua CHEN ; Li GONG ; Yi-Bin YANG ; Xiao-Ping YANG ; Ying LI ; Jian-Xin WAN ; Nian-Song WANG ; Hai-Ying LI ; Chun-Sheng XI ; Li HAO ; Yan XU ; Jing-Ai FANG ; Bi-Cheng LIU ; Rong-Shan LI ; Rong WANG ; Jing-Hong ZHANG ; Jian-Qin WANG ; Tan-Qi LOU ; Feng-Min SHAO ; Feng MEI ; Zhi-Hong LIU ; Wei-Jie YUAN ; Shi-Ren SUN ; Ling ZHANG ; Chun-Hua ZHOU ; Qin-Kai CHEN ; Shun-Lian JIA ; Zhi-Feng GONG ; Guang-Ju GUAN ; Tian XIA ; Liang-Bao ZHONG ; null
Chinese Medical Journal 2013;126(12):2276-2280
BACKGROUNDData on the epidemiology of hypertension in Chinese non-dialysis chronic kidney disease (CKD) patients are limited. The aim of the present study was to investigate the prevalence, awareness, treatment, and control of hypertension in the non-dialysis CKD patients through a nationwide, multicenter study in China.
METHODSThe survey was performed in 61 tertiary hospitals in 31 provinces, municipalities, and autonomous regions in China (except Hong Kong, Macao, and Taiwan). Trained physicians collected demographic and clinical data and measured blood pressure (BP) using a standardized protocol. Hypertension was defined as systolic BP ≥ 140 mmHg and/or diastolic BP ≥ 90 mmHg, and/or use of antihypertensive medications. BP < 140/90 mmHg and < 130/80 mmHg were used as the 2 thresholds of hypertension control. In multivariate logistic regression with adjustment for sex and age, we analyzed the association between CKD stages and uncontrolled hypertension in non-dialysis CKD patients.
RESULTSThe analysis included 8927 non-dialysis CKD patients. The prevalence, awareness, and treatment of hypertension in non-dialysis CKD patients were 67.3%, 85.8%, and 81.0%, respectively. Of hypertensive CKD patients, 33.1% and 14.1% had controlled BP to < 140/90 mmHg and < 130/80 mmHg, respectively. With successive CKD stages, the prevalence of hypertension in non-dialysis CKD patients increased, but the control of hypertension decreased (P < 0.001). When the threshold of BP < 130/80 mmHg was considered, the risk of uncontrolled hypertension in CKD 2, 3a, 3b, 4, and 5 stages increased 1.3, 1.4, 1.4, 2.5, and 4.0 times compared with CKD 1 stage, respectively (P < 0.05). Using the threshold of < 140/90 mmHg, the risk of uncontrolled hypertension increased in advanced stages (P < 0.05).
CONCLUSIONSThe prevalence of hypertension Chinese non-dialysis CKD patients was high, and the hypertension control was suboptimal. With successive CKD stages, the risk of uncontrolled hypertension increased.
Adult ; Aged ; Awareness ; Female ; Humans ; Hypertension ; complications ; epidemiology ; therapy ; Male ; Middle Aged ; Prevalence ; Renal Insufficiency, Chronic ; complications
5.Effect of High Suspension and Low Incision Surgery Based on Traditional Ligation of Chinese Medicine in Treatment of Mixed Haemorrhoids: A Multi-centre, Randomized, Single-Blind, Non-inferiority Clinical Trial.
Xiao-Qiang JIA ; Wei-Wei CAO ; Long-Fang QUAN ; Wei-Bing ZHAO ; Fang CHENG ; Shan JIA ; Liu-Quan FENG ; Xu-Feng WEI ; Zhen-Nian XIE ; Dong WANG ; Chun-Yan XU ; Chun-Hui CUI ; Xing-Juan CAI ; Lan-Ye HE ; Zhan-Jun WANG ; Ying TIAN ; Shu-Min SHI ; Si-Miao SUN ; Liang SU ; Meng-Fan ZHAI
Chinese journal of integrative medicine 2021;27(9):649-655
OBJECTIVE:
To observe the clinical effect of high suspension and low incision (HSLI) surgery on mixed haemorrhoids, compared with Milligan-Morgan haemorrhoidectomy.
METHODS:
A multi-centre, randomized, single-blind, non-inferiority clinical trial was performed. Participants with mixed haemorrhoids from Xiyuan Hospital of China Academy of Chinese Medical Sciences, Beijing Rectum Hospital, Air Force Medical Center of People's Liberation Army of China, and Puyang Hospital of Traditional Chinese Medicine were enrolled from September 2016 to March 2018. By using a blocked randomization scheme, participants were assigned to two groups. The experimental group was treated with HSLI, while the control group was treated with Milligan-Morgan haemorrhoidectomy. The primary outcome was the clinical effect evaluated at 12 weeks after operation. The secondary outcomes included the number of haemorrhoids treated during the operation, pain scores, use of analgesics, postoperative oedema, wound healing, incidence of anal stenosis, anorectal manometry after operation, as well as surgical duration, length of stay and total hospitalization expenses. A safety evaluation was also conducted.
RESULTS:
In total, 246 eligible participants were enrolled, with 123 cases in each group. There was no significant difference in the clinical effect between the two groups (100.00% vs. 99.19%, P>0.05). Compared with the control group, the number of external haemorrhoids treated during the operation and the pain scores after operation were significantly reduced in the experimental group (P<0.05 or P<0.01); the patient number with wound healing at 2 weeks after operation and the functional length of anal canal at 12 weeks after operation were significantly increased in the experimental group (P<0.05). There was no significant difference in the incidence of anal stenosis, the numbers of patients using analgesics and patients with postoperative oedema between the two groups after operation (P>0.05). The surgical duration and length of stay in the experimental group were significantly longer than those in the control group, and the total hospitalization expense was significantly higher than that in the control group (all P<0.05). No adverse events were reported in either group during the whole trial or follow-up period.
CONCLUSION
HSLI had the advantages of preserving the skin of anal canal completely, alleviating postsurgical pain and promoting rapid recovery after operation. (Registration No. ChiCTR1900022883).
6.Analysis of Factors Associated with Death in Maintenance Hemodialysis Patients: A Multicenter Study in China.
Kang-Kang SONG ; De-Long ZHAO ; Yuan-Da WANG ; Yong WANG ; Xue-Feng SUN ; Li-Ning MIAO ; Zhao-Hui NI ; Hong-Li LIN ; Fu-You LIU ; Ying LI ; Ya-Ni HE ; Nian-Song WANG ; Cai-Li WANG ; Ai-Hua ZHANG ; Meng-Hua CHEN ; Xiao-Ping YANG ; Yue-Yi DENG ; Feng-Min SHAO ; Shu-Xia FU ; Jing-Ai FANG ; Guang-Yan CAI ; Xiang-Mei CHEN
Chinese Medical Journal 2017;130(8):885-891
BACKGROUNDPatients on hemodialysis have a high-mortality risk. This study analyzed factors associated with death in patients on maintenance hemodialysis (MHD). While some studies used baseline data of MHD patients, this study used the most recent data obtained from patients just prior to either a primary endpoint or the end of the study period to find the characteristics of patients preceding death.
METHODSParticipants were selected from 16 blood purification centers in China from January 2012 to December 2014. Patients' data were collected retrospectively. Based on survival status, the participants were divided into two groups: survival group and the death group. Logistic regression analysis was performed to determine factors associated with all-cause mortality.
RESULTSIn total, 4104 patients (57.58% male, median age 59 years) were included. Compared with the survival group, the death group had more men and more patients with diabetic nephropathy (DN) and hypertensive nephropathy. The patients preceding death also had lower levels of diastolic blood pressure, hemoglobin, serum albumin, serum calcium, serum phosphate, Kt/V, and higher age. Multivariate analysis revealed that male sex (odd ratio [OR]: 1.437, 95% confidence interval [CI]: 1.094-1.886), age (OR: 1.046, 95% CI: 1.036-1.057), and presence of DN (OR: 1.837, 95% CI: 1.322-2.552) were the risk factors associated with mortality. High serum calcium (OR: 0.585, 95% CI: 0.346-0.989), hemoglobin (OR: 0.974, 95% CI: 0.967-0.981), albumin (OR: 0.939, 95% CI: 0.915-0.963) levels, and dialysis with noncuffed catheter (OR: 0.165, 95% CI: 0.070-0.386) were protective factors based on a multivariate analysis.
CONCLUSIONSHemodialysis patients preceding death had lower hemoglobin, albumin, and serum calcium levels. Multivariate analysis showed that male sex, age, DN, low hemoglobin, low albumin, and low serum calcium were associated with death in hemodialysis patients.
Adult ; Aged ; China ; Female ; Humans ; Male ; Middle Aged ; Multivariate Analysis ; Renal Dialysis ; adverse effects ; mortality ; Retrospective Studies ; Risk Factors
7.Safety, Effectiveness, and Manipulability of Peritoneal Dialysis Machines Made in China: A Randomized, Crossover, Multicenter Clinical Study.
Xue-Ying CAO ; Ya-Ni HE ; Jian-Hui ZHOU ; Shi-Ren SUN ; Li-Ning MIAO ; Wen CHEN ; Jing-Ai FANG ; Ming WANG ; Nian-Song WANG ; Hong-Li LIN ; Jian LIU ; Zhao-Hui NI ; Wen-Hu LIU ; Yu NA ; Jiu-Yang ZHAO ; Zhi-Yong GUO ; Hong-Guang ZHENG ; Wei SHI ; Geng-Ru JIANG ; Guang-Yan CAI ; Xiang-Mei CHEN
Chinese Medical Journal 2018;131(23):2785-2791
Background:
Automated peritoneal dialysis (APD) can cater to individual needs, provide treatment while asleep, take into account the adequacy of dialysis, and improve the quality of life. Currently, independent research and development of APD machines made in China are more conducive to patients. A randomized, multicenter, crossover study was conducted by comparing an APD machine made in China with an imported machine. The safety, effectiveness, and manipulability of the two machines were compared.
Methods:
Two hundred and sixty patients who underwent peritoneal dialysis (PD) on a regular basis in 18 centers between August 2015 and February 2016 were included. The inclusion criteria include age ≥18 years and PD ≥30 days. The exclusion criteria were as follows: hemodialysis; exit site or tunnel infection; and peritonitis ≤30 days. The patients were randomly divided into Group A, who were first treated with a FM machine made in China, then changed to an imported machine; and Group B, who were treated using the reverse sequence. APD treatment was performed with 10 L/10 h and 5 cycles of exchange. After 72 h, the daily peritoneal Kt/V, the accuracy of the injection rate, accuracy of the injection temperature, safety, and manipulability of the machine were assessed. Noninferiority test was conducted between the two groups.
Results:
The daily peritoneal Kt/V in the APD machine made in China and the imported APD machine were 0.17 (0.14, 0.25) and 0.16 (0.13, 0.23), respectively. There was no significant difference between the groups (Z = 0.15, P = 0.703). The lower limit of the daily Kt/V difference between the two groups was 0.0069, which was greater than the noninferiority value of -0.07 in this study. The accuracy of the injection rate and injection temperature was 89.7% and 91.5%, respectively, in the domestic APD machine, which were both slightly better than the accuracy rates of 84.0% and 86.8% in the imported APD machine (89.7% vs. 84.0%, P = 0.2466; 91.5% vs. 86.8%, P = 0.0954). Therefore, the APD machine made in China was not inferior to the imported APD machine. The fuselage of the imported APD machine was space-saving, while the APD machine made in China was superior with respect to body mobility, man-machine dialog operation, alarm control, and patient information recognition.
Conclusions:
The FM machine made in China was not inferior to the imported APD machine. In addition, the FM machine made in China had better operability.
Trial Registration
Clinicaltrials.gov, NCT02525497; https://clinicaltrials.gov/ct2/results?cond=&term=NCT02525497&cntry=& state=&city=&dist=.
Adult
;
China
;
Cross-Over Studies
;
Female
;
Humans
;
Male
;
Middle Aged
;
Multicenter Studies as Topic
;
Peritoneal Dialysis
;
adverse effects
;
instrumentation
;
methods
;
Quality of Life
;
Temperature