1.Progress of “Cocktail" probe substrates approaches
Ying LIU ; Jianjie JIAO ; Jianshi LOU
Chinese Journal of Clinical Pharmacology and Therapeutics 2004;0(11):-
The method of simultaneous administration of several probe substrates is called “Cocktail" approaches. The objective of the article is to review the application of this technique in characterizing the activity of multiple drug-metabolizing enzymes and in clinical researches. This paper also shows Five-drug and Six-drug Cocktail set for evaluating in vivo activity of drug-metabolizing enzymes.
2.Comparative study of optical coherence tomography angiography and ICGA in central serous chorioretinopathy
Bin, MO ; Hai-Ying, ZHOU ; Xuan, JIAO ; Wu, LIU
International Eye Science 2017;17(7):1351-1355
AIM:By analyzing optical coherence tomography angiography (OCTA) characteristics of central serous chorioretinopathy (CSC) and comparing the differences of CSC between OCTA and indocyanine green angiography(ICGA), to explore if OCTA can substitute ICGA for diagnosis of CSC patients, and guide the treatment of photodynamic therapy (PDT).METHODS: We reviewed 30 eyes of 30 patients with CSC, who were diagnosed by fluorescein angiography (FFA) and ICGA at Beijing Tongren Eye Center from November 2015 to March 2016.All patients underwent best-corrected visual acuity (BCVA) measurement, intraocular pressure, slit-lamp examination, indirect ophthalmoscope, color fundus photography, FFA, ICGA and OCTA.FFA and ICGA were captured by Spectralis HRA + OCT (Spectralis HRA + OCT;Heidelberg Engineering, Heidelberg, Germany).OCTA was performed by RTVue XR Avanti device (OptovueInc, Fremont, CA) with 6mm×6mm Angio Retina mode.The software (version 2017.100.0.1;OptovueInc) automatically segmented the tissue into four layers, the characteristics of choriocapillaris layer were analyzed.At the same time, the differences between OCTA and ICGA images were compared among CSC patients.The maximum diameters and areas of both choroidal hyperperfusion in ICGA and high flow signal in OCTA were measured.Then, the paired t test was used to analyze the differences between the maximum diameter and area of OCTA and ICGA measurement.RESULTS: Among 30 cases, high blood flow signals of OCTA were clearly visible in 27 cases, namely the coarse grain region;the inner low flow signals surrounded by high blood flow signals were seen in 21 cases;the outer low flow signals surrounding high blood flow signals were seen in 7 cases.High blood flow signals of OCTA were corresponded with the choroidal hyperperfusion of ICGA images;among these 30 cases, there were low reflection shadows in choroidal hyperperfusion with ICGA for 22 cases, for 21 cases out of these 22 cases, low flow signals inside of high flow signals of OCTA could be seen;9 out of 30 cases, there were low reflection halo outside of choroidal hyperperfusion of ICGA, and 7 out of these 9 cases, low flow signals outside of high flow signals of OCTA could be seen;still for those 30 cases, leakage point in late ICGA could be seen with 14 cases, however, special flow signals in OCTA could not be seen for them.For ICGA, the maximum diameter of choroidal hyperperfusion was 1.589±0.295mm, whose area was 0.705±0.131mm2;while for OCTA, the maximum diameter of high flow signal was 1.576±0.293mm, whose area was 0.745±0.138mm2.By using paired t test, there was no statistical difference between the maximum diameter of choroidal hyperperfusion in ICGA and the maximum diameter of high flow signal in OCTA, nor difference between the area of ICGA and OCTA.CONCLUSION: The high flow signals can be clearly visible in OCTA, which are corresponded with choroidal hyperperfusion in ICGA.OCTA can substitute ICGA for diagnosis of CSC patients, and guide the treatment of PDT.
3.The influence of different dosage of protamine neutralization heparin on perioperation of on-pump coronary artery bypass grafting
Ying TIAN ; Jingxue JIAO ; Xuwei LIU ; Shanshan HAN ; Weitie WANG
Tianjin Medical Journal 2017;45(7):726-729
Objective To investigate the effect of different doses of protamine neutralizing heparin on perioperation of on-pump coronary artery bypass graftting (CABG).Methods A total of 180 on-pump CABG patients hospitalized from January 2015 to November 2016 were randomly divided into three groups,the protamine group l,protamine group 2 and protamine group 3,60 patients in each group.Heparin (3 mg/kg) was used before extracorporeal circulation.After intracardiac operation was over,protamine was used to neutralize the heparin to adjust the activated clotting time (ACT) in protamine group 1,which was 10% higher than that of intubation.Meanwhile,protamine group 2 was neutralized to equal to the ACT before intubation,and protamine group 3 was 10% lower than that before the intubation.The differences of intraoperative and postoperative parameters were compared between the three groups.Results No death was found in the three groups during hospitalization.Comparing with protamine group 1 and protamine group 2,the time of operation,the ACT before the leaving operation room,the ACT of the first hour after returning to ICU,the amount of bleeding during operation,the time of closing and the amount of red blood for transfusion were decreased in protamine group 3 (P > 0.05).The total amount of protamine for neutralizing and the ratio of protamine and heparin were significantly increased in protamine group 3 (P < 0.05).The heart dysfunction after operation,perioperative myocardial infarction,pulmonary edema,pulmonary infection,renal dysfunction,poor wound healing,neurological complications,and time of in hospital stay showed no significant differences between three groups (P>0.05).Conclusion ACT below 10% of preoperation is safe,after neutralization of heparin by protamine,which can obviously reduce the bleeding,the time of sternal closure and the amount of red blood cell transfusion,showing a positive clinical significance.
4.Consistency Study of PowerPlex?21 Kit and GoldeneyeTM 20A Kit and Forensic Application
He REN ; Ying LIU ; Qingxia ZHANG ; Zhangping JIAO
Journal of Forensic Medicine 2014;(3):191-193
To ensure the consistency of genotype results for PowerPlex?21 kit and GoldeneyeTM 20A kit. Methods The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. Results All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P>0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymor-phism information content was 0.810. Conclusion PowerPlex?21 kit and GoldeneyeTM 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.
5.Establishment and effect assessment of complementary succession mode
Lili XIA ; Jinfeng WU ; Ying LIU ; Jiao ZHU ; Heng JIANG
Chinese Journal of Practical Nursing 2016;32(32):2542-2545
Objective To explore the establishment and evaluation of various forms of complementary transfer. Methods The former method using the traditional handover method, the establishment of various forms of complementary shift model improved, including optimized bedside handover, handover of patients′ bedsore image and emotional barometer over emotional changes, establish WeChat group to observe improvement;the first two months (99 cases, monitoring 42 days) and the improvement after the six months (97 cases, monitoring 43 days) score of nurses for the patient to grasp, bedside shift time and transfer the missing information. Concrete research and implementation methods, research objects, sample size, measurement indicators, evaluation methods, etc. Results Both shift mode, there is no information on patients admitted to general statistical difference (P>0.05);under complementary shift mode, nurse the patients′ condition from the master score (80.95 ± 4.30) points increased to (84.88 ± 4.01) points, in which the patients′condition data mastery score from (40.81 ± 2.02) points increased to (44.16 ± 2.88) points, nursing problems and measures of control points value from (13.21 ± 1.54) points increased to (14.44 ± 1.72) points, the difference was statistically significant (t =4.362, 6.209, 3.462, P<0.01);general information master score, treatment information at its disposal no difference scores statistically significant (P>0.05). Bedside nurse shift change time decreased from former improvements (31.21 ± 2.63) minutes to (14.42 ± 2.40) minutes, and the difference was statistically significant (t=30.767, P=0.000). Shift nurse missing information dropped from 16 times to 7 times, the difference was statistically significant (χ2=5.124, P=0.024). Conclusions Complementary model can reduce the insufficiency of current clinical succession work, help nurse master the patients′physical and mental conditions and more comprehensive understanding of the ward, reduce the omission or missing information and improve the working efficiency and responsibility.
6.Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application.
He REN ; Ying LIU ; Qing-Xia ZHANG ; Zhang-Ping JIAO
Journal of Forensic Medicine 2014;30(3):191-193
UNLABELLED:
To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit.
METHODS:
The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained.
RESULTS:
All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810.
CONCLUSION
PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.
DNA/analysis*
;
DNA Fingerprinting
;
DNA Primers
;
Genotype
;
Heterozygote
;
Humans
;
Microsatellite Repeats
;
Paternity
;
Polymerase Chain Reaction
;
Polymorphism, Genetic
7.Preparation and Characteristics of Patterned TiO2 Thin Film onTC4 Made by Sol-gel Method
Journal of Medical Biomechanics 2010;25(1):E021-E025
Objective To improve the long-term biocompatibility and mechanical stability of Titanium alloy implants. Method micro-nano patterned TiO2 thin films have been prepared on TC4 substrates via a sol-gel dip-coating method with Ti(OC4H9)4 (TEOT) as precursor and polyethylene glycol (PEG) as organic template. The influence of PEG concentration upon the morphology of the target films has been studied by using AFM. The wettability and tribological properties of the target films have been studied by means of optical contact angle measuring instrument and UMT-2. Results When increasing the PEG concentration to 3.5g/100mL, a parallel arranged groove structure can be obtained on the surface of the sample; compare with TiO2 sol-gel film without adding organic template, the wear resistance of the patterned film is better. Conclusions The feature of the patterned TiO2 films can be controlled by adding different amount of organic template; and it has been proved that a certain kind of patterned structure can improve the wear resistance of the film.
8.Quality control of multicenter nursing investigation research
Jing JIAO ; Xinjuan WU ; Xiaojing ZHANG ; Zhen LI ; Jing CAO ; Ge LIU ; Ying LIU
Chinese Journal of Nursing 2017;52(5):589-591
Quality management of scientific research is a systematic work,quality control of multicenter nursing research depends on perfect and effective quality management system,measures and procedures,as well as rigorous scientific attitude in project team. To establish and improve quality management system of scientific research,to for-mulate standard quality control procedures,to promote the usage of electronic data acquisition system in multicenter nursing researches,and to improve scientific,standard,and refined quality management of research are effective mea-sures to guarantee quality control of multicenter nursing research. This paper summarized quality control methods for multicenter investigation,to provide more experience for nursing researchers as references.
9.Multicenter survey on nurses' knowledge and attitude on common complications among bedridden patients in Chinese hospitals
Jiaqian LI ; Jing CAO ; Jing JIAO ; Zhen LI ; Ge LIU ; Ying LIU ; Fangfang LI ; Xinjuan WU
Chinese Journal of Nursing 2017;52(3):327-331
Objective To investigate the knowledge and attitude of nurses on prevention and intervention of common complications among bedridden patients in Chinese hospitals and to explore the influential factors.Methods It was a cross-sectional study.A total of 3 903 nurses from 6 tertiary hospitals,11 secondary hospitals and 8 primary hospitals from 6 provinces and cities were recruited by convenience sampling and surveyed using selfdesigned questionnaires.Results Nurses' average scoring rate of knowledge and attitude were 73.46% and 85.02%.Level of hospitals,whether in ICU or not,age,working time,educational background,job title,position,employment form were influential factors for nurses' knowledge (P<0.05).Meanwhile,level of hospitals,educational background,position,employment form were influential factors for nurses' attitude (P<0.05).Conclusion Nurses took a positive attitude for prevention and intervention of common complications among bedridden patients,while the level of nurses' knowledge should be improved.
10.Design and application of the electronic data capture system in multi-center nursing study
Zhen LI ; Jing JIAO ; Jing CAO ; Ge LIU ; Ying LIU ; Fangfang LI ; Xiaojing ZHANG ; Xinjuan WU
Chinese Journal of Nursing 2017;52(6):730-733
We designed and applied the electronic data capture system (EDC) in order to strengthen the re-search quality and improve the efficiency of data collection of multi-center nursing research. According to the needs of research,we reasonably designed the EDC structure and functions,including data collection,verification, summary and export. Further improvement was performed after EDC was inputted into using. By using EDC,resear-chers from sub-centers completed the data collection smoothly,and the data quality met with research requirements. The design and application of EDC could effectively guarantee the data quality and improve the research efficiency.