1.Development and application of universal and specific diagnostic reagents for human respiratory adenovirus
Jing, CHEN ; Zhang-yi, QU ; Feng-xiaug, WEI ; Hong-yau, ZHANG ; Peng, WANG ; Ying-chen, WANG ; Hai-ying, JIANG
Chinese Journal of Endemiology 2008;27(6):686-690
Objective To establish a specific,sensitive,simple human respiratory adenovirus detection method to put a good experimental foundation for developing universal and specific diagnostic reagents of human respiratory adenovirus.Methods The nucleotide sequences of 10 serotype of human respiratory adenovirus were obtained from GenBank.Highly consewed five pairs of universal and specific adenovirus primers were designed on the evaluation of multiple sequence alignment of the 10 full genomic sequences with the software DNAMAN 5.2.2,Gene Runner 3.05,BLAST,and to ensure that the polymerase chain reaction(PCR)products were type-specific.NP-40 sample lytic method was employed to prepare the template.The effectiveness,specificity and sensitivity of primers were evaluated.And PCR was carried out to test 64 samples of throat swabs of acute respiratory infection children.The positive PCR products were sequenced directly to identify the adenovirus serotypes.The positive specimens was inoculated on HeLa cells to observe cytopathie effect(CPE)under light microscope,and virus morphology were observed under electron microscope.Results BLAST results indicated that the five pairs of primers were specific adenovirus primers with low homology to the others.The primers were identified as PCR positive fragments obtained by using five pairs of primers to amplify the human adenovirus type 3 DNA,which did not react to the respiratory syncytial virus and Coxsackie virus.the effectiveness and specificity of the primer were thus indicated.PCR sensitive results showed 10-5 dilutin of adenovirus culture and DNA sample could be deteeted which meant the method was sensitive and stable.Two PCR positive specimens were detected in 64 clinical samples.the positive rate was 3.13%(2/64).Using the two PCR positive specimens to inoculate the HeLa cells,the typical adenovirus CPEs of rounded and aggregated,detatched cells were observed under light microscope.And a large number of adenovirus typical particles with characteristic lattice arrangement were observed in the infected cells under electron microscope.PCR product sequencing results showed that these two isolated adenoviruses were typed in human adenovims group B.Conclusions Universal and specific adenovirus PCR primers with the serotype specificity of the PCR products were designed successfully.The PCR primers was sensitive and specific and could be routinely applied in clinical adenovirus diagnosis for respiratory specimens.
2.Virtual reality mobile application to improve videoscopic airway training: A randomised trial.
Ying Wei YAU ; Zisheng LI ; Mui Teng CHUA ; Win Sen KUAN ; Gene Wai Han CHAN
Annals of the Academy of Medicine, Singapore 2021;50(2):141-148
INTRODUCTION:
Flexible bronchoscopic intubation (FBI) is an important technique in managing an anticipated difficult airway, yet it is rarely performed and has a steep learning curve. We aim to evaluate if the integration of virtual reality gaming application into routine FBI training for emergency department doctors would be more effective than traditional teaching methods.
METHODS:
We conducted a randomised controlled trial to compare self-directed learning using the mobile application, Airway Ex* in the intervention group versus the control group without use of the mobile application. All participants underwent conventional didactic teaching and low-fidelity simulation with trainer's demonstration and hands-on practice on a manikin for FBI. Participants randomised to the intervention arm received an additional 30 minutes of self-directed learning using Airway Ex, preloaded on electronic devices while the control arm did not. The primary outcome was time taken to successful intubation.
RESULTS:
Forty-five physicians (20 junior and 25 senior physicians) were enrolled, with male predominance (57.8%, 26/45). There was no difference in time taken to successful intubation (median 48 seconds [interquartile range, IQR 41-69] versus 44 seconds [IQR 37-60], P=0.23) between the control and intervention groups, respectively. However, the intervention group received better ratings (median 4 [IQR 4-5]) for the quality of scope manipulation skills compared to control (median 4 [IQR 3-4], adjusted P=0.03). This difference remains significant among junior physicians in stratified analysis.
CONCLUSION
Incorporating virtual reality with traditional teaching methods allows learners to be trained on FBI safely without compromising patient care. Junior physicians appear to benefit more compared to senior physicians.
3.Comparison of Reusable Models in Pericardiocentesis Simulation Training.
Ziwei LIN ; Crystal Harn Wei SOH ; Mui Teng CHUA ; Jingping LIN ; Cheryl Jing Yi HO ; Julia Ying Hui LEE ; Fang Yu Tracy SHEN ; Ying Wei YAU ; Win Sen KUAN
Annals of the Academy of Medicine, Singapore 2020;49(12):971-977
INTRODUCTION:
Pericardiocentesis is a potentially life-saving procedure. We compared two low-cost models-an agar-based model and a novel model, Centesys-in terms of ultrasound image quality and realism, effectiveness of the model, and learners' confidence and satisfaction after training.
METHODS:
In this pilot randomised 2x2 crossover trial stratified by physician seniority, participants were assigned to undergo pericardiocentesis training either with the agar-based or Centesys model first, followed by the other model. Participants were asked to rate their confidence in performing ultrasound-guided pericardiocentesis, clarity and realism of cardiac structures on ultrasound imaging, and satisfaction on a 7-point Likert scale before and after training with each model.
RESULTS:
Twenty participants with median postgraduate year of 4 (interquartile range [IQR] 3.75-6) years were recruited. Pre-training, participants rated themselves a median score of 2.5 (IQR 2-4) for level of confidence in performing pericardiocentesis, which improved to 5 (IQR 4-6) post-training with Centesys (
CONCLUSION
Centesys achieved greater learner satisfaction as compared to the agar-based model, and was an effective tool for teaching ultrasound-guided pericardiocentesis and drain insertion.
4.Pre- and apnoeic high-flow oxygenation for rapid sequence intubation in the emergency department (the Pre-AeRATE trial): A multicentre randomised controlled trial.
Mui Teng CHUA ; Wei Ming NG ; Qingshu LU ; Matthew Jian Wen LOW ; Amila PUNYADASA ; Matthew Edward COVE ; Ying Wei YAU ; Faheem Ahmed KHAN ; Win Sen KUAN
Annals of the Academy of Medicine, Singapore 2022;51(3):149-160
INTRODUCTION:
Evidence regarding the efficacy of high-flow nasal cannula (HFNC) oxygenation for preoxygenation and apnoeic oxygenation is conflicting. Our objective is to evaluate whether HFNC oxygenation for preoxygenation and apnoeic oxygenation maintains higher oxygen saturation (SpO2) during rapid sequence intubation (RSI) in ED patients compared to usual care.
METHODS:
This was a multicentre, open-label, randomised controlled trial in adult ED patients requiring RSI. Patients were randomly assigned 1:1 to either intervention (HFNC oxygenation at 60L/min) group or control (non-rebreather mask for preoxygenation and nasal prongs of at least 15L/min oxygen flow for apnoeic oxygenation) group. Primary outcome was lowest SpO2 during the first intubation attempt. Secondary outcomes included incidence of SpO2 falling below 90% and safe apnoea time.
RESULTS:
One hundred and ninety patients were included, with 97 in the intervention and 93 in the control group. Median lowest SpO2 during the first intubation attempt was 100% in both groups. Incidence of SpO2 falling below 90% was lower in the intervention group (15.5%) compared to the control group (22.6%) (adjusted relative risk=0.68, 95% confidence interval [CI] 0.37-1.25). Post hoc quantile regression analysis showed that the first quartile of lowest SpO2 during the first intubation attempt was greater by 5.46% (95% CI 1.48-9.45%, P=0.007) in the intervention group.
CONCLUSION
Use of HFNC for preoxygenation and apnoeic oxygenation, when compared to usual care, did not improve lowest SpO2 during the first intubation attempt but may prolong safe apnoea time.
Adult
;
Cannula
;
Emergency Service, Hospital
;
Humans
;
Intubation, Intratracheal
;
Rapid Sequence Induction and Intubation
;
Respiration, Artificial