1.Thrombolysis efficiency of urokinase plasminogen activator-loaded anionic lipid microbubbles combined with low-frequency ultrasound in vitro
Yihan CHEN ; Ping WANG ; Fei YAN ; Fei NI ; Hongmei LIU ; Hairong ZHENG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2014;34(2):121-124
Objective To prepare urokinase plasminogen activator (uPA)-loaded anionic lipid microbubbles (uPA-MBs) for thrombolysis with low-frequency ultrasound in vitro.Methods Anionic microbubbles composing of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC),1,2-dipalmitoyl-sn-glycero-3-phospho-(l'-rac-glycerol) (DPPG),1,2-distearoyl-sn-glycero-3-phosphoethanol amine-N (succinyl PEG2000) (DSPE-PEG2000) and perfluoropropane (C3F8) were prepared by the mechanical vibration method.Then,the resulting anionic microbubbles were incubated with uPA.uPA-MBs were obtained via electrostatic adsorption.Bubble size and distribution were measured by particle size analyzer.FITC-labeled uPA-MBs were obtained and observed under fluorescence microscope.The surface potential of uPA-MBs and plain microbubbles (P-MBs) were detected by Zeta potential analyzer.Sodium dodecyl sulfonate-polyacrylamide gel electrophoresis (SDS-PAGE) was used for confirming the binding of uPA protein and anionic microbubbles.The encapsulation efficiency of uPA-MBs was determined by bicinchoninic acid (BCA) protein assay kit under three different dosages of uPA (10 000,50 000 and 100 000 U).The thrombolysis efficiency of uPA-MBs combined with low-frequency ultrasound was examined in vitro.Two-sample t test,one-way analysis of variance and Bonferroni test were performed to analyze the data.Results UPA-MBs were successfully obtained with the mean particle size of (1.76±0.29) μm.The surface potential of these bubbles was significantly higher than that of P-MBs:(-36.64±0.21) mV vs (-66.33±2.38) mV (t =21.538,P<0.05).Fluorescence microscope showed a green shell of FITC-labeled uPA-MBs.The encapsulation efficiency of uPAMBs with the added dosage of 10 000 U was (42.01±2.02) %,which was significantly higher than those of 50000 and 100 000 U ((33.24±1.95)% and (33.10±1.65)% respectively,F=22.340,P<0.05).The thrombolysis efficiency by saline was (4.09±0.80)%,saline + ultrasound (8.50±1.48)%,MBs + ultrasound (14.27± 1.59) %,uPA-MBs + ultrasound (35.72±6.31) % and uPA (16.87±0.46) %,respectively (F =48.783,t =-8.613,-7.273,-5.942,-6.908,all P<0.05).Conclusion Anionic microbubbles can successfully load uPA,and achieve significantly better thrombolysis effect when combined with low-frequency ultrasound.
2.Investigation of viremia persistence time in genotype 4 hepatitis E virus infection
Yihan LU ; Anqun HU ; Yingjie ZHENG ; Yiyun TAN ; Fadi WANG ; Xinsen YU ; Qingwu JIANG
Chinese Journal of Infectious Diseases 2009;27(9):535-539
Objective To determine the persistence time of genotype 4 hepatitis E (HE) viremia after the onset of clinical symptoms in HE patients and provide essential data for study on HE epidemiologieal transmission, so that to evaluate potential contagiousness of HE patients after clinical stage. Methods The first serum samples from 162 HE patients after hospitalized in Eastern China were collected and tested for hepatitis E virus (HEV) RNA by nested reversed transcription- polymerase chain reaction (RT-PCR). The persistence time of HEV viremia after the onset of clinical symptoms was estimated with Kaplan-Meier survival analysis. Results HEV RNA was detectable in 101 out of 162 serum samples with positive rate of 62.35%, which was all grouped to genotype 4 by homology analysis. Furthermore, HEV RNA was detectable in 74 (64.91%) out of 114 male and 27 (56.25%) out of 48 female, which was not significantly different (χ2 = 1.08, P=0. 30). Kaplan-Meier survival analysis showed that the median persistence time of HEV genotype 4 viremia was 24 days after the onset of clinical symptoms (95% CI: 18-30 days), which meant that the viremia of 50% HE patients remaining detectable up to 24 days after the onset. The 75% and 25% percentiles were 14 days and 31 days, respectively. There was no significant difference of viremia persistence time between male and female (Breslow test: P=0.98, Tarone-Ware test: P=0.91). Conclusions The viremia of 75% patients with HEV genotype 4 infection could persistent until 2 weeks after the onset of clinical symptoms and that of some patients could persistent over 1 month. It is indicated that the viremia is still persistent and HE patient could be a reservoir even after the clinical symptoms disappeared and biochemical marks normalized.
3.Factors of Families Related to Outcome of Rehabilitation for Cerebral Palsy Children
Chunlei WANG ; Jiaxing XIE ; Wenjuan LI ; Xiujuan GU ; Zhijun LI ; Weili QU ; Yihan ZHENG
Chinese Journal of Rehabilitation Theory and Practice 2014;20(11):1083-1085
Objective To investigate the factors of families related to the outcome of rehabilitation for cerebral palsy children. Methods Families of 153 cerebral palsy children were investigated with questionnaires of family condition, knowledge of cerebral palsy, compliance,and the Eysenck Personality Questionnaire, Marital Quality Questionnaire, Social Support Scale, Symptom Check List, Happiness Index.The children were assessed with Comprehensive Assessment for Disable Children before and after rehabilitation. Results There were significant differences of compliance, knowledge of cerebral palsy, being of other healthy children, personality of extraversion/introversion and lying,and mental symptom between the families of the cerebral palsy children improved or not after rehabilitation (P<0.05). Multivariate Logistic regression analysis showed that, being of other healthy children, personality of extraversion/introversion and mental symptom were the independent factors. Conclusion It may relate to the outcome of rehabilitation for cerebral palsy children of family condition, personality and mental health of the families, which need further intervention.
4.A study on epithelial cell adhesion molecule targeted nucleic acid aptamer drug conjugate in gastric cancer targeted treatment
Tao PAN ; Yihan ZHENG ; Hui CAO ; Lin TU ; Yang SUN
Chinese Journal of Digestive Surgery 2023;22(10):1219-1225
Objective:To investigate the affinity and toxicity of epithelial cell adhesion molecule (EpCAM) targeted nucleic acid aptamer drug conjugate SYL3C-MMAE on human gastric epithelial cells GES-1 (hereinafter referred to as GES-1 cells) and human gastric cancer cells AGS and MKN45 (hereinafter referred to as AGS cells and MKN45 cells).Methods:The experimental study was conducted. The expression level of EpCAM in gastric cancer tissues was detected using immunohistochemistry. The mRNA expression level of EpCAM in gastric cancer tissues was detected using real-time fluorescence quantitative PCR (RT-PCR). The expression level of EpCAM protein in GES-1, AGS and MKN45 cells was detected using Western blot. The affinity of SYL3C on GES-1, AGS and MKN45 cells was detected using flow cytometry. SYL3C-MMAE was synthesized through a thiol-maleimide reaction. The toxicity of drugs on GES-1, AGS and MKN45 cells was detected using CCK-8 assay. The cell cycle condition of GES-1, AGS and MKN45 cells after drug treatment was detected using propidium iodide (PI) staining. Observation indicators: (1) expression of EpCAM in gastric cancer; (2) affinity of antibodies targeting EpCAM and SYL3C on GES-1, AGS and MKN45 cells; (3) situation of drug synthesis; (4) drug toxicity and inhibition of cell cycle. Measurement data with normal distribution were represented as Mean± SD. One-way ANOVA was used for comparison among multiple groups, and pairwise comparison was conducted using the least significant difference test. Comparison of unequal variances was conducted using the Welch' t test. Measurement data with skewed distribution were represented as M(IQR), and comparison between groups was conducted using the paired rank sum test. Count data were described as absolute numbers, comparison between groups was conducted using the paired chi-square test. Results:(1) Expression of EpCAM in gastric cancer. Results of immunohistochemistry on tissue microarrays showed that the positive rate of EpCAM was 82.9%(29/35) and 22.9%(8/35) in the 35 pairs of gastric cancer and its adjacent tissues (normal tissues), respectively, showing a significant difference between them ( P<0.05). Results of RT-PCR showed that the mRNA relative expression levels of EpCAM was 1.23 (4.13) and 4.04 (1.72) in 12 pairs of gastric cancer and its adjacent tissues respectively, showing a significant difference between them ( Z=-2.67, P<0.05). Results of Western blot showed that the relative expression levels of EpCAM protein in GES-1, AGS, and MKN45 was 0, 1.00, and 0.27, respectively, with the expression level of EpCAM protein in AGS cells as the standard. (2) Affinity of antibodies targeting EpCAM and SYL3C on GES-1, AGS and MKN45 cells. Results of flow cytometry showed that antibodies targeting EpCAM and SYL3C had good affinity on AGS and MKN45 cells but no affinity on GES-1 cells. (3) Situation of drug synthesis. Results of mass spectrometry showed that the drug solution of compound formed by connecting SYL3C with monomethylorestatin E (VcMMAE) exhibited a strong peak at the molecular weight position of 16 355, consistent with the expected molecular weight of the SYL3C-MMAE complex, indicating that SYL3C-MMAE was successfully synthesized. (4) Drug toxicity and inhibition of cell cycle. Results of CCK-8 assay showed that the half maximal inhibitory concentration (IC 50) of VcMMAE on GES-1, AGS and MKN45 cells was 123.00, 30.48 and 51.83 nmol/L, respectively. The IC 50 of SYL3C-MMAE on GES-1, AGS and MKN45 cells was 241.80, 20.66 and 27.64 nmol/L, respectively. Results of PI staining and flow cytometry showed that both VcMMAE and SYL3C-MMAE could induce G2/M phase blockage in the cell cycle of GES-1, AGS and MKN45 cells. Conclusion:The SYL3C-MMAE has a good affinity on gastric cancer cells. Compared with VcMMAE, SYL3C-MMAE exhibits efficient inhibition on gastric cancer cells, but less influence on normal cells.
5.Changes of cytokines IL-4 and IFN-γ of serum in patients with chronic insomnia and mild cognitive impairment
Xinwei ZHENG ; Dong LI ; Lijuan GENG ; Chenfei LIU ; Su MA ; Huimiao LIU ; Yihan LIU ; Sai ZHANG ; Ping GU
Chinese Journal of Behavioral Medicine and Brain Science 2020;29(8):700-705
Objective:To investigate the characteristics of serum cytokine IL-4 and IFN- γ levels in patients with chronic insomnia with mild cognitive impairment (MCI), and to further explore the relationship between cognitive function and IL-4 and IFN-γ in patients with chronic insomnia.Methods:Sixty-two patients with chronic insomnia were divided into MCI group( n=30) and non-MCI group( n=32) according to the scores of Montreal cognitive assessment(MoCA), mini-mental state examination(MMSE) score and chief complaint of cognitive decline. Pittsburgh sleep quality index(PSQI), Hamilton depression scale(HAMD 24) and Hamilton anxiety scale 14 item(HAMA 14) were evaluated. Serum IL-4 and IFN-γ were detected by flow fluorescence, correlation analysis and regression analysis were carried out. Results:The levels of IL-4 and IFN-γ in MCI group were significantly lower than those in non-MCI group (IL-4: 0.875(0.143, 1.655)μg/L, 1.855(0.813, 2.723)μg/L; IFN-γ: 0.450(0.173, 1.163)μg/L, 1.160(0.483, 3.075)μg/L, all P<0.05). There was no significant difference in IFN- γ/IL-4, PSQI, HAMA 14 and HAMD 24 scores between MCI group and non-MCI group. IL-4 was positively correlated with the total score of MoCA( r=0.318, P<0.05), orientation( r=0.324, P<0.05)and delayed recall( r=0.368, P<0.01). The results of multivariate regression showed that IL-4 had significant effects on MCI in patients with chronic insomnia( B=2.161, OR=8.682, 95% CI=2.058~36.633, P=0.003). Conclusion:The cognitive function of chronic insomnia is closely related to serum IL-4 and IFN-γ, and serum IL-4 has a protective effect on cognition in chronic insomnia patients. Therefore, it can be speculated that cytokines may be an important pathophysiological link of cognitive change in chronic insomnia patients.
6.Design and Experimental Research of Portable Extracorporeal Circulation Pipeline Performance Testing System.
Song LIU ; Ganying WANG ; Yihan WANG ; Ling PENG ; Jinlu ZHENG
Chinese Journal of Medical Instrumentation 2022;46(2):164-167
Aiming at the current situation of performance testing of hemodialysis extracorporeal circulation tubing, which has slow efficiency, inaccurate measurement, and inconvenient testing, a portable detection system for testing the performance of hemodialysis extracorporeal circulation tubing is designed. The system mainly includes a hardware system and a software system. The hardware system uses STM32F407 single-chip microcomputer as the core to design the driving control of the roller pump; the software system uses the C++ real-time operating system, and the flow detection data is transmitted to the upper computer through RS485 communication and displayed. Experimental showed that the system detects the accuracy and the stability of the flow rate. It has the characteristics of stability and high precision. The relative error of the experimental measurement is within the range of ±10%. The weight of the whole machine is 2 kg, which improves the efficiency by 50% compared with the traditional detection method.
Computers
;
Equipment Design
;
Extracorporeal Circulation
;
Microcomputers
;
Renal Dialysis
;
Software
7.Quantitative determination and optimun extraction technique of nine compounds of .
Yihan FENG ; Lei YIN ; Yuanrong LIU ; Lujing CAO ; Ning ZHENG ; Mingjuan LI ; Shuyu ZHAN
Journal of Zhejiang University. Medical sciences 2020;49(3):356-363
OBJECTIVE:
To establish the optimum extraction technique and high performance liquid chromatographic (HPLC) method to simultaneously quantify nine compounds of gallic acid, hydroxy-paeoniflorin, catechin, albiflorin, paeoniflorin, pentagalloylglucose, benzoic acid, benzoylpaeoniflorin and paeonol in .
METHODS:
Linear gradient elution was applied using water containing 0.1%phosphoric acid and acetonitrile as the mobile phase with a flow rate of 0.8 mL/min, column temperature of 30℃ and wavelength of 230 nm. The method of ultrasound extraction was used. Methanol and ethanol were used as extraction solvents, and three factors and three levels of orthogonal experiments was designed using L (3 ) table to investigate the effects of solvent concentration, ratio of liquid to material and extraction time on the total content of nine components of .
RESULTS:
HPLC method was verified to have high specificity, sensitivity and accuracy through methodological validation, and it could be used for simultaneous quantitative analysis of nine components of . The results showed that the optimum extraction technology of nine components of was using 70%ethanol as extraction solvent, ratio of liquid to material was 200 mL/g and ultrasound extraction time was 30 min.
CONCLUSIONS
HPLC method for the simultaneous determination of nine components of is established, and the optimum extraction technology is confirmed.
Chromatography, High Pressure Liquid
;
Drugs, Chinese Herbal
;
Paeonia
8.Analysis of Three-Dimensional Gait Characteristics before and after FSPR Surgery of Patients with Spastic Cerebral Palsy
Jie ZHANG ; Yihan XU ; Siyu LIN ; Caixia LI ; Wen XIA ; Jiejiao ZHENG
Journal of Medical Biomechanics 2021;36(5):E712-E717
Objective To analyze gait characteristics of patients with spastic cerebral palsy (CP) before and after functional selective posterior rhizotomy (FSPR) surgery, so as to evaluate curative effects of the surgery objective ly. MethodsFifteen patients with spastic CP to be treated by FSPR were selected. The VICON three-dimensional (3D) motion analysis system and AMTI 3D force plates were used to collect and analyze the spatiotemporal gait parameters, kinematic and dynamic parameters before and after FSPR surgery. Results After the surgery, the left and right support phases were longer,and the left-side step length was significantly larger. The step height, velocity and the max displacement of center of gravity (COG) in coronal plane were smaller than those before surgery.The sagittal plane angle (flexion and extension angle) of the knee during initial landing was significantly increased, while no significant differences were found in that of the hip and ankle.The range of motion (ROM) of the left/right hip, knee and ankle in sagittal plane was increased to some extent during walking, with statistical differences. The ROM of right ankle in coronal plane was also increased obviously. The minimum flexion angle of the right knee and the maximum plantar flexion angle of the left/right ankle were significantly reduced. The maximum vertical forces of left and right support phases were significantly increased, while no significant differences were found in torque of lower limbs. Conclusions The 3D gait analysis can be used to evaluate the effect of FSPR on patients with spastic CP. The spasticity of patients with spastic CP is relieved after FSPR surgery, and the spatiotemporal gait parameters and kinematics parameters are improved significantly. But the improvement of dynamic parameters was not obvious, and further rehabilitation treatment is needed.
9.Pathogenic mutation in a patient with Oguchi disease
Luqi XIA ; Xuebi CAI ; Yihan ZHENG ; Xinran WEN ; Fangyue ZHOU ; Nobuyuki NAO-I ; Zibing JIN
Chinese Journal of Ocular Fundus Diseases 2020;36(3):192-195
Objective:To identify the pathogenic mutation in a patient with Oguchi disease.Methods:A Japanese patient with Oguchi disease was enrolled in this study, and underwent a comprehensive medical history assessment and multiple ophthalmic examinations, including BCVA, OCT, color fundus photography and full field electroretinogram. Genomic deoxyribonucleic acid (DNA) was extracted from peripheral blood samples for whole exome sequencing. The gene mutation was detected, and the analysis software was used to determine the conservation of the mutation and the possible structural changes.Results:The patient, 71 years old, with consanguineous parents, complained of night blindness since early childhood. BCVA in both eyes was 0.7 and the golden-yellowish reflex appeared in the grey retina. The scotopic 0.01 ERGs showed a extinguished reaction in both eyes. The scotopic 3.0 ERGs showed a "negative" configuration with a significantly reduced a wave and a nearly absent b wave. A homozygous deletion mutation in the SAG gene (c.924delA, p.N309Tfs*12) in this patient was founded by DNA sequencing, which was predicted to generate prematurely truncated SAG protein and result in severe structural change. Homology analysis of the protein sequence indicated that the mutation resulted in an altered amino acid which was evolutionarily highly conserved among different species, strongly suggesting the potential pathogenicity of this homozygous mutation.Conclusion:The mutation c.924delA(309Tfs*12) in SAG cause Oguchi disease in this patient.