1.Decursin inhibits EC109 cells proliferation via suppression of JAK2/STAT3 signaling pathway
Changkang KE ; Yuying LIU ; Zhipei ZHANG ; Jiao ZHANG ; Yifang ZHU ; Jinwei LIU ; Ziqian WANG ; Jinbo ZHAO ; Xiaofei LI
Chinese Journal of Thoracic and Cardiovascular Surgery 2018;34(4):230-236
Objective To investigate whether decursin(Dec) could inhibit EC109 cells proliferation by suppression of janus kinase 2/signal transducer and activator of transcription 3 (JAK2/STAT3) signaling pathway in human esophageal squamous cell carcinoma.Methods The EC109 cells were treated with Dec(20,40,and 80 pmmol/L) for48 h.The cell viability was evaluated by MTT;the apoptotic cells was labelled by TUNEL;the mitochondrial oxidative stress level was detected by fluorescent staining;and western blotting was used to analyze the proteins of JAK2/STAT3 signaling and apoptosis in EC109 cells,respectively.After co-application of JAK2 / STAT3 antagonist(AG490),the inhibitory ability of Dec to EC109 was observed from the in vivo and in vitro levels.Results Compared to the control group,different concentrations of Dec dose-dependently down-regulated expressions of p-JAK2 [(55.89 ± 6.04) %] and p-STAT3 [(45.27 ± 8.65) %],repressed EC109 cell activity(0.43 ± 0.078),increased apoptotic rate[(35.31 ± 8.41)%],reduced MMP levels[(37.23 ± 6.89)%],promoted reactive oxygen species(ROS) [(231.81 ± 19.63)%],decreased glutathione (GSH) activity [(46.78 ± 6.91)%,P<0.05].However,Dec did not significantly affect the activity of the normal esophageal epithelium HET-1A cells(P >0.05).Meanwhile,Dec obviously leaded to reduction of Bcl2,increment of Bax,and augment of Caspase-3 cleavage (P <0.05).Additionally,the inhibitory effect of Dec on EC109 was specifically intensified after co-application of AG490 in vivo and in vitro levels(P <0.05).Conclusion Dec can fight against human esophageal squamous cell carcinoma in vitro and in vivo via activation of mitochondrial oxidative stress-induced apoptosis which was mediated by JAK2/STAT3 pathway.
2.Analysis on risk factors for norovirus outbreaks in Guangdong province, 2008-2015
Fen YANG ; Limei SUN ; Hui LI ; Lili GUO ; Ling FANG ; Xiaohua TAN ; Yifang LONG ; Changwen KE ; Jianfeng HE
Chinese Journal of Epidemiology 2017;38(7):906-910
Objective To analyze transmission factors of norovirus outbreaks in Guangdong province during 2008-2015 and provide evidence for the prevention and control of norovirus infection.Methods Epidemiological analysis was performed on the data of norovirus outbreaks reported in Guangdong from January 1,2008 to December 31,2015,which were obtained from the Public Health Emergency Management Information System of Guangdong province.The samples collected from the norovirus outbreaks were detected for norovirus by RT-PCR and the gene sequencing of the positive PCR products were performed.Results A total of 96 norovirus outbreaks were reported in Guangdong during 2008-2015.Sixteen outbreaks were reported during 2008-2012and 80 outbreaks were reported during 2013-2015 (83.3%).Eighty-two outbreaks (85.4%) occurred in schools.The infection routes included foodborne transmission in 39 outbreaks (40.6%),person to person transmission in 23 outbreaks (24.0%) and waterborne transmission in 8 outbreaks (7.3%).The gene sequencing results showed that variant G Ⅱ.4/Sydney2012 was the predominant pathogen for 6 of the 20 outbreaks (30.0%) during 2012-2013.Variant G lⅡ.17 was the predominant pathogens for 33 of the 53 outbreaks (62.3%) during 2014-2015.Conclusion The norovirus outbreaks in Guangdong during 2008-2015 were caused by foodborne and person to person transmissions of two emerging variant:G Ⅱ.4/Sydney2012 and G Ⅱ.17.
3.Quantitative study of intraoral scanners′ accuracy
Junkai CHEN ; Yuchun SUN ; Hu CHEN ; Yue CAO ; Yifang KE ; Yongsheng ZHOU
Chinese Journal of Stomatology 2021;56(9):920-925
Objective:To establish a standard method to evaluate the scanning accuracy of intraoral scanner (IOS) and to investigate six IOS′s scanning accuracy and the relationship between different scan span.Methods:Five simplified six abutments full arch model were fabricated by high accuracy (5 μm) milling machine with 7075 aluminum alloy. The machining accuracy, which was verified by a coordinate measuring machine with higher accuracy (0.7 μm), was considered as the reference accuracy. The model with the highest machining accuracy was considered as the test model in IOS′s scanning accuracy test, and computer-aided design (CAD) data of the model was used as the reference data. Six IOS scanned the test model 10 times with the same scanning path, obtained 60 test data. CAD data and test data were input into Geomagic Studio 2014. The preparation part above the margin of the abutments of the data was isolated and divided into 4 segments of interest: single crown, three-unit bridge, five-unit bridge, and full arch. The test data were then best-fit aligned to CAD data or each other followed by deviation analysis. Scanning trueness and precision were then calculated.Results:The mid-value of scanning trueness and precision of six IOS in single crown, three-unit bridge, five-unit bridge and full arch were 13.3-29.6 μm and 7.6-20.7 μm, 15.4-30.9 μm and 8.7-26.5 μm, 17.0-66.1 μm and 11.3-44.2 μm, 24.0-107.9 μm and 24.6-150.1 μm respectively.Conclusions:Long-span scanning can affect the accuracy of IOS to a varying extent.
4.Application and outlook of robotics in prosthetic dentistry
Yifang KE ; Yaopeng ZHANG ; Yong WANG ; Yuchun SUN
Chinese Journal of Stomatology 2021;56(9):939-944
At present, robotic system has been applied in many aspects of the field of prosthetic dentistry, such as tooth preparation, oral implant surgery, full denture arrangement, prosthodontic material testing and robotic education of prosthodontics. The advantages of prosthodontic robotics lie in their ability to perform quantitative and precise operations whilerepeating the work flow indefinitely, which assist dentists to complete heavy and complicated daily treatment. In the research and development of prosthodontic robotics, the limitation of oral operation space should be fully considered, and robotics should have high safety and flexibility. The review briefly summarizes the application and existing problems of robotics in prosthodontics, and provides references for further development and design.