1.Relationship between the cancer patients'right to know the true diagnosis and their satisfaction degree with nursing service
Chinese Journal of Practical Nursing 2008;24(12):69-71
Objective To study the relationship between the cancer patients'right to know the true diagnosis and their satisfaction degree with nursing service. Methods We randomly selected 746 patients from the tumor center, the circulation department,the respiration department and surgery department.Questionnaires were designed according to patients'right to know the true diagnosis and the results were analyzed. Results Cancer patients who don't know the true diagnosis wanted to acquire the true information about their diseases but nurses were supposed to keep secret of the actual diagnosis.This contradiction led to the impediment of communication between patients andf nurses compared with other department(P<0.05). Conclusion The right to know their true diagnosis proved to be important for cancer patients in that it could increase the compliance of patients and promote communications so that patients would accept nursing service and the satisfaction degree with nursing service would improved.
2.Comparison of Q-value guide LASIK and standardized LASIK for the treatment of myopia:a meta-analysis
Jie-liang, SHI ; Yi-fan, FENG ; Shi-hao, CHEN ; qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(5):437-443
Background Nowadays,customized ablation is widely used in the excimer laser corneal refractive Burgery.And the Q-value guide LASIK is one of the research hotspots. Objective Present study was to evaluate and compare the effectiveness of Q-value guide LASIK and standardized LASIK for myopia.Methods A systematic literature retrieval from 2003 through 2010 was conducted in the MEDLINE,CNKI,Cochrane Library,EMBASE.The literature examine possible difierences in uncorrected visual acuity(UCVA),Q-value,higher order aberrations(HOAs),and spherical equivalent(SE) between Q-value guide LASIK and standardized LASIK for correcting myopia.Statistical analysis was performed using a Review Manager 5.0 software.The data was extracted,and the methodological quality was evaluated by two reviewers independently.The quality of included literature was scored according to the Jadad Scale. Results A total of 14 studies involving 1617 patients(2956 eyes)was included in the meta-analysis.Of these fourteen studies,six studies were randomized trials and the other eight studies were retrospective cohort studies.According to the Jadad Scale,2 studies scored 3 points,and the other 12 studies scored 1~2 points.The results showed that the Q-value guide LASIK group had a better postoperative effectiveness in uncorrective visual acuity(UCVA)(WMD=0.04.95% CI 0.00 to 0.08,P<0.05).Q-value(SMD=-1.52,95% CI -2.23 to-0.81,P=0.00),total HOAs (SMD=-1.63,95% CI-2.57 to-0.69,P<0.05) and spherical-like aberrations ( SMD =-1.49,95% CI-2.22 to-0. 76,P<0. 00) after surgery. However, the number of eyes achieved UCVA≥20/20 ( OR= 1.16,95% CI 0. 61 to 2. 19,P=0. 65) ,coma-like aberrations (SMD=-1. 02,95% CI-0. 36to 0.11,P=0.29) and SE (WMD=0.10,95% CI-0.11 to 0.31,P=0.34) after surgery were comparable.Conclusion The effectiveness of Q-value guide LASIK is superior to standardized LASIK for treatment of myopia.High-quality clinical randomized-controlled study should be performed to further evaluate the comparable outcome of Q-value guide LASIK with standard LASIK.
3.Exploration of homogeneous care at Hunan Provincial People's Hospital
Yuelan QIN ; Zeya SHI ; Zhoumin SHEN ; Yimin ZHU ; Xiaomao SHI ; Jinyan ZHOU ; Yi YANG
Chinese Journal of Hospital Administration 2016;32(6):470-472
An introduction to the Basic service module featuring holistic,full flow and seamless connection built by the hospital.Authors described their experiences in achieving homogenous clinical nursing care,and pointed out that integrating medical humanistic care into the daily nursing process,can improve doctor-patient relationship and patients satisfaction,thus raising medical service quality and efficiency.
4.The mechanism of tenuigenin for eliminating waste product accumulation in cerebral neurons of Alzheimer's disease rats via ubiquitin-proteasome pathway.
Qin CHEN ; Yi-Qing CHEN ; Hai-Yan YE ; Jain-Qi YU ; Qi-Quan SHI ; Yan HUANG
Chinese Journal of Integrated Traditional and Western Medicine 2015;35(3):327-332
OBJECTIVETo explore the scavenging action of tenuigenin (TEN) on intracerebral amyloid β protein (Aβ) aggregation and the abnormal phosphorylated tau protein and its mechanism in Alzheimer's disease (AD) rats' brain.
METHODSAβ1-40 was injected into the right CA1 region hippocampus to establish the AD model. Successfully modeled rats were divided into the model group, the low, middle, high TEN group. Rats were administered with TEN (18.5, 37.0, 74.0 mg/kg) by gastrogavage. Besides, a sham-operation group was set up. Expression levels of Aβ1-40 and Tau p-Ser262 were detected by immunohistochemistry. Expression levels of ubiquitin (Ub) and Ub-protein ligase E3 were measured by Western blotting.The content of 26S proteasome was detected by ELISA.
RESULTSImmunohistochemical results showed that the number of Aβ and Tau p-Ser262 positively reacted neurons significantly increased in model group, when compared with the sham-operation group (P < 0.01). Results of Western blot showed expression levels of ubiquitinated protein were up-regulated and those of Ub-protein ligase E3 were down-regulated in the model group (P < 0.01). ELISA results showed that the content of 26S proteasome significantly decreased in AD rats' brain (P < 0.01). Compared with the model group, expression levels of Aβ1-40, Tau p-Ser262, and Ub significantly decreased; expression levels of Ub-protein ligase E3 apparently increased; the content of 26S proteasome significantly increased in each TEN treatment group (P < 0.05, P < 0.01). Best effect was shown in 37.0 mg/kg and 74.0 mg/kg TEN groups.
CONCLUSIONSUb proteasome pathway (UPP) participated in the occurrence of AD. TEN could obviously reduce intracere- bral Aβ1-40 accumulation and abnormal tau phosphorylation.
Alzheimer Disease ; metabolism ; Amyloid beta-Peptides ; Animals ; Drugs, Chinese Herbal ; pharmacology ; Hippocampus ; metabolism ; Neurons ; metabolism ; Phosphorylation ; Proteasome Endopeptidase Complex ; metabolism ; Rats ; Ubiquitin-Protein Ligases ; metabolism ; Ubiquitins
5.Jinlong capsule combined with chemoradiotherapy for NSCLC: a Meta-analysis.
Qiang LU ; Jing-bin LUO ; Yi-fan FENG ; Qin SHE ; Zhong-feng SHI
China Journal of Chinese Materia Medica 2015;40(22):4491-4496
The purpose of this study was to evaluate the effect and safety of Jinlong capsule combined with chemotherapy or radio-therapy for non-small cell lung cancer (NSCLS) using Meta-analysis. PubMed, Embase, CNKI and Wanfang databases were all searched without language restriction, and searching time was from January 1990 to July 2015. All eligible published studies were included in this study for quality assessment and data extraction. All the data were analyzed using Revman 5.3. A total of ten studies including 736 subjects (370 in Jinlong capsule plus chemoradiotherapy and 366 in chemoradiotherapy only) were finally included in this Meta-analysis. The result of Meta analysis showed that compared with pure chemoradiotherapy group, Jinlong capsule combined with chemoradiotherapy for NSCLC could improve the patients' curative effect (OR = 1.77, 95% CI: 1.29-2.43, P < 0.05), clinical benefit rate (OR = 1.89, 95% CI: 1.22-2.91, P < 0.05), life quality improvement rate (OR = 2. 56, 95% CI: 1.61-4.05, P < 0.05), and decrease leucopenia incidence rate (OR = 0.35, 95% CI: 0. 22-0.56, P < 0.05) and gastrointestinal reaction rate (OR = 0.67, 95% CI: 0.40-1.11, P < 0.05). The pooled results showed that Jinlong capsule combined with chemoradiotherapy for NSCLC could improve the curative effect and life quality, and decrease the adverse reaction of patients.
Antineoplastic Combined Chemotherapy Protocols
;
administration & dosage
;
Capsules
;
administration & dosage
;
Carcinoma, Non-Small-Cell Lung
;
drug therapy
;
radiotherapy
;
Chemoradiotherapy
;
Combined Modality Therapy
;
Drugs, Chinese Herbal
;
administration & dosage
;
Humans
;
Lung Neoplasms
;
drug therapy
;
radiotherapy
6.Meta-analysis of clinical effectiveness of on-flap and off-flap epi-LASIK for myopia
Yi-fan, FENG ; Shi-hao, CHEN ; Xin-jun, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(3):269-275
Background Recently,whether the epithelial flaps should be removed or preserved during the Epi-LASIK and its affection on clinical results are concerned.Objecfive This system analysis was to evaluate and compare the clinical effectiveness between on-flap Epi-LASIK and off-flap epi-LASIK for myopia. Methods A systematic literature retfieval was conducted in the MEDLINE,EMBase,Coehrane Library,CBM disc,CNKI from 2003 through 2009.The possible differences in reepithelization time,pain sensation,and haze after surgery were compared between on-flap and off-flap Epi-LASIK for myopia.The statistical analysis was performed using a RevMan 4.2 software.The data was extracted,and the methodological quality was evaluated by two reviewers independently with weighted mean difierence(WMD)for the effectiveness analysis and odds ratio(OR)for counting variable.The quality of included literature was scored according to the Jadad Scale. Results A total of 8 studies involving 251 patients(502 eyes)were included in the meta-analysis.Of these eight studies.five studies were randomized clinical trials and the other three studies were retrospective cohort studies.Compared with on-flap Epi-LASIK group,off-flap Epi-LASIK group had a better postoperative outcome in the mean reepithelization time(WMD=1.32,95%CI-1.82to-0.82,P<0.01)and pain scores at 3,5 day(WMD=-O.99,95%CI-1.71 to-0.28,P(0.01)(WMD=-0.94.95%CI-1.35 to-0.54,P<0.01)after surgery.No significant difierenees were found in the eye numbers of haze at 1 month(OR=0.62,95%C1 0.34 to 1.12,P=0.11),3 months(OR=0.70,95%C1 0.31 to 1.55,P=0.38)and 6 months(OR=1.14,95%C1 0.58 to 2.26,P=0.71)between these two types of operation.The pain scores at the first day after surgery was not significantly different between these two groups(WMD=-0.17,95%CI -0.55 to 0.20,P=0.37). Conclusion The effectiveness of off-flap Epi-LASIK is superior to on-flap Epi-LASIK for myopia.Some high-quality randomlizd and control studies are needed for the further clinical evaluation.
7.Meta analysis of randomized controlled clinical trial in the effect of hinge location on dry eye syndrome after LASIK
Yi-fan, FENG ; Ji-guo, YU ; Jie-liang, SHI ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(9):847-852
Background Dry eye syndrome is a frequent postoperative complication of laser in situ keratomileusis (LASIK).Some studies reported that the hinge location of corneal flap has influence on dry eye syndrome following LASIK,but others showed inverse views.Objective This systematic review was to evaluate and compare the effects of a superior-and nasal/temporal-hinge location on dry eye syndrome after LASIK.Methods A systematic literature retrieval was conducted in the Medline,Embase,Cochrane Library and CNKI from 1990 to 2011 according to designed searching strategy and relevant words.Published randomized-controlled clinical trial (RCT) data of the effect of superior-and nasal/temporal-hinge location on dry eye syndrome were extracted by two researchers separately.The outcome parameters,such as tear film breakup time (BUT),Schirmer Ⅰ test and corneal sensation were analyzed 1 week,3 months and 6-12 months postoperatively.The statistical analysis was performed using a RevMan 5.0 software and the quality of included literatures were graded according to the Jadad scale.Fixedeffect model was used for the inhomogeneity multiple studies (P≥0.1,homogeneity test I2 <50%),and random-effect model was used for the homogeneity studies.Results Ten pieces RCT papers were searched and 3 of them were rejected because of the lack of outcome data.In 7 included studies,652 eyes of 331 patients were involved in the Meta analysis,with the Jadad scores ≥ 3.BUT assessment was performed in 5 trials (530 eyes),Schirmer Ⅰ test evaluation was in 7 trials (652 eyes) and corneal sensation observation was in 4 trials (320 eyes),without significant homogeneity among the relevant literature(I2<50%).Meta analysis revealed that BUT in the eyes with superior-hinge group was obvious shorter than that in the eyes nasal/temporal-hinge group at 1 week (WMD =-0.42,95% CI:-0.79 to-0.06,P=0.020),but there was no signifieant difference in 3 months and 6-12 months duration postoperatively.Better corneal sensation was found at postoperative 3 months (WMD=-0.62,95%CI:-l.09 to-0.19,P=0.005) in the nasal/temporal-hinge group,but there was no difference in 1 week and 6-12 months duration postoperatively.No significant difference was seen between the two groups in Schirmer Ⅰ test during the follow-up period (P>0.05).Conclusions LASIK with nasal/temporal-hinge corneal flap can improve the corneal sensation and relief the dry eye syndrome after LASIK to some extent.More high-quality evidence-based studies are still needed for the further clinical evaluation.
8.Meta analysis of deep lamellar keratoplasty and penetrating keratoplasty for keratoconus
Jie-liang, SHI ; Yi-fan, FENG ; Ji-guo, YU ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;(10):926-931
Background Nowadays,keratoplasty is widely used in the treatment of keratoconus.Deep lamellar keratoplasty(DLKP)is one of the research hotspots.However,its effacacy and safety are still concerned.Objective This paper was to evaluate and compare the therapeutic outcomes between DLKP and penetrating keratoplasty(PKP) for keratoconus.Methods The peer-reviewed and published literature was searched from PubMed database,Cochrane Library,EMBase and CNKI to identify relevant trails comparing DLKP with PKP for keratoconus.Methodological quality and Meta-analysis were carried out according to the principle of evidence-based medicine.The statistical analysis was performed using Review Manager 5.0 software.Results Eleven studies with 2950 eyes were identified that compared the results of DLKP and PKP procedures for keratoconus directly.Of those studies reporting vision and refractive data,less patients underwent DLKP achieved a best corrected visual acuity (BCVA)of≥0.5 than DLKP(RR=0.91,95% CI:0.84-0.99,P=0.030) ;patients with DALK had severer myopia that those with PKP(RR =-0.60,95% CI:-1.43-0.23,P =0.150),but the astigmatism was comparative (WMD =0.21,95% CI:-0.48-0.91,P =0.550).Endothelial cell density values were higher in the DLKP group and the differences were significant.Endothelial immune graft rejection did not occur after DALK,and PKP had a higher overall graft rejection rate than DLKP(RR=0.06,95% CI:0.01-0.31,P=0.001).Conclusions According to the available data,PKP can imporve the BCVA and refractive results,but DLKP can avoid the risk of endothelial rejection and reduce the risk of late endothelial failure for keratconus.
9.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.
10.The BSA Structure Disruption by Ultrasound and High Pressure Treatment
Zhao-Feng LUO ; Xin QU ; Wan-Meng MU ; Qin SHI ; Yi ZHANG ;
China Biotechnology 2006;0(01):-
To investigate the structure disruption of BSA (1mg/ml, dissolved in PBS) induced by ultrasonication and the French press. The BSA solution was passed through the French press and received ultrasound irradiation, and then detected by HPLC(High-performance liquid chromatography),DLS(Dynamic Light Scattering),CD(Circular Dichroism)and nondenaturing SDS-PAGE. Detection results showed that BSA was polymerized after ultrasound irradiation and the polymerization can be reduced by adding mannitol (free radical scavenger). This means that the free radical play an important role in this process. However, the BSA passing through the French press for several times wasn’t polymerized, and the secondary structure was somewhat destroyed. These results suggested that ultrasound irradiation and French press destroy the molecular structure in different manners, so that the suitable cell lyses methods should be selected according to the characteristics of the protein.