4.Effects of simulated air diving on oxygen free radicals in rat splenic tissue.
Wei-Gang XU ; Heng-Yi TAO ; Shi-Ming CHEN
Chinese Journal of Applied Physiology 2006;22(2):194-224
Air
;
Animals
;
Diving
;
Male
;
Rats
;
Rats, Sprague-Dawley
;
Reactive Oxygen Species
;
metabolism
;
Spleen
;
metabolism
5.The effects of glycyrrhiza uralensis and glucocorticoid on sera interleukin-8 of smoking rats
Beilei ZHAO ; Hua XIONG ; Ming QI ; Yi SHI
Journal of Medical Postgraduates 2003;0(03):-
0.05]. Conclusion: Cigarettes smoking may increase the levels of sera IL-8 in rats,and it can been depressed by glycyrrhiza uralensis and glucocorticoid respectively,however glycyrrhiza uralensis show significantly faster and were powerful action than glucocorticoid.
6.Application of three-dimensional digital subtraction angiography in the evaluation of ruptured intracranial aneurysm after clipping
Hui SHI ; Bing ZHAO ; Ming ZHONG ; Yi ZHANG ; Kuang ZHENG ; Zequn LI ; Xianxi TAN
The Journal of Practical Medicine 2014;(7):1024-1027
Objective To assess the application of three-dimensional digital subtraction angiography (3D-DSA) in evaluation of ruptured intracranial aneurysm after clipping and to discuss the different variable use of vol-ume rendering(VR), gradient rendering (GR) and maximum intensity projection (MIP). Methods From January 2011 to December 2012 , 88 patients with 92 ruptured intracranial aneurysms were treated with clipping using titani-um clips in our hospital and followed up by both 2D-DSA and 3D-DSA. Residual aneurysms , Clips place, clips and parent arteries and stenosis of parent arteries were evaluated by volume rendering (VR), gradient rendering (GR) and maximum intensity projection (MIP). Results Among 92 clipped aneurysms, 23 residual aneurysms were found by 3D-DSA. Residual aneurysms were recorded according to the Sindou grade: 15 of gradeⅠ, 3 of gradeⅡ, 4 of grade Ⅲand 1 of grade Ⅳ. Three patients of grade Ⅲand 1 of grade Ⅳwith residual aneurysms were retreated by clipping or coiling, and 1 patient of grade Ⅲ was dead with rupture of residual aneurysm. The clips and number of clips were clearly visualized , and relationship between the clips and the aneurysms was well demonstrated by VR, GR and MIP images. VR, GR images showed the remnants clearly. Three-dimensional digital subtraction angiography did not showed accurate details of the stenosis of parent arties which required an analysis of 2D-DSA. Conclusion Three-dimensional digital subtraction angiography can be used for definite evaluation of resid-ual aneurysms after clipping, especially by VR, GR images. It is helpful to manage the residual ruptured aneurysms.
7.The Impact of PET-CT on Precise Radiotherapy Planning for Advanced Non-Small Cell Lung Cancer
Fang ZHANG ; Tao SHI ; Zhibin LANG ; Mingjuan SUN ; Ming ZHOU ; Yi ZHAO
Tianjin Medical Journal 2014;(11):1109-1111
Objective To investigate the impact of PET-CT on the target volume delineation and precise radiothera?py planning for patients with advanced non-small cell lung cancer (NSCLC). Methods PET-CT scanning was performed in 30 histologically proved NSCLC patients. The gross tumor volume (GTV) was delineated, and radiotherapy planning was es?tablished with identical parameters based on the CT image and PET-CT fused image, respectively. The differences of doses between GTV, planning target volume (PTV) and organsat rise (OAR) were compared. Results PET-CT image results changed the target volume delineation in 30 patients with 8 increased and 22 decreased. There were no differences in GTV and PTV between the VGTV and VPTV statistically, although PET-CT image changed conventional CT image size sketch of GTV and PTV. The V20 of total lung decreased in the PlanPET-CT compared with that of PlanCT (P<0.05), but no differences were found in the V30 of total lung, mean lung dose (MLD), the data of spinal cord, esophagus and heart. Conclusion PET-CT may reduce the radiation injuries in the lung and improve the target dose.
8.Nuclear factor ?B in LPS stimulated rat alveolar macrophages promotes TNF-? secretion
Fang ZHANG ; Ziling LI ; Yi SHI ; Ming ZHAO ; Xiaofeng XIN ; Guisheng QIAN
Chinese Journal of Pathophysiology 2000;0(07):-
AIM:To investigate the activation of nuclear factor ?B(NF-?B) induced by lipopolysaccharides(LPS) in rat alveolar macrophages(AMs) and its regulatory role in tumor necrosis factor(TNF-?) secretion.METHODS:The dynamic activity changes of NF-?B induced by LPS were determined with electrophoretic mobility shift assay(EMSA).Antisense oligonucleotides of NF-?B subunit(p65) were transfected into AMs prior to LPS stimulation.The effect of antisense oligonucleotide transfection on expressions of p65 and TNF-? in supernatant were measured with Western blotting and enzyme linked immunosorbent assay(ELISA),respectively.RESULTS:NF-?B activity increased markedly and reached its peak level at 4 h after LPS stimulation.After transfected with antisense oligonucleotides of NF-?B subunit(p65),expression of p65 and TNF-? in supernatant decreased markedly.CONCLUSION:NF-?B activity has a positive effect on regulating secretion of TNF-? in AMs induced by LPS.
9.Biodistribution and radioimmunoimaging of 131 I-Herceptin in healthy KM mice and nude mouse models bearing human ovarian cancer xenografts
Yi-zhen, SHI ; Min-chao, XIONG ; Jian-ming, HU ; Zeng-li, LIU ; Ben-xing, ZHU
Chinese Journal of Nuclear Medicine 2010;30(3):170-175
Objective To study the biodistribution of anti-HER-2/neu monoclonal antibody Herceptin labeled by 131I(131I-Herceptin) in healthy KM mice and nude mice bearing human ovarian cancer xenografts and radioimmunoimaging (RII) of the nude xenografts-bearing mice.Methods 131I-Herceptin was prepared using Iodogen method.The labeling efficiency, radiochemical purity, stability and immunocompetence were measured.The percentage activity of injection dose per gram of tissue (%ID/g) and the radioactivity ratio of tumor to non-tumor tissue (T/NT) were calculated for each time point.The optimal time for imaging was investigated by comparing the 131I-Herceptin SPECT for the nude mouse models bearing ovarian cancer xenografts at different time points.Results The labeling efficiency and radiochemical purity of 131I-Herceptin were 89.8% and 98.4%, respectively.The labeling was stable and had good immunocompetence.131 I-Herceptin was cleared rapidly mainly through liver, spleen and kidneys, consistent with first order two-compartment model.The uptake of 131I-Herceptin in the tumors bearing human SKOV-3 xenografts was much higher than that in nontumor tissue.The% ID/g was 18.08 in the tumor at 24 h post injection.The T/NT ratio increased with time and was 27.27 at 72 h post injection.The tumors in nude mice bearing SKOV-3 xenografts could be visualized on 131I-Herceptin SPECT imaging 2 h post injection; definitely identiffed 48 h post injection and the radioactivity ratio of tumor to contralateral tissue was 11.44 at 120 h post injection.However, the tumor in nude mice bearing HO-8910 xenografts did not show abnormal uptake of 131 I-Herceptin at each time point.Conclusions 131 I-Herceptin is a good radiopharmaceutical targeting SK-OV-3 xeuografts and it may be useful in imaging carcinoma of ovary and target therapy of its metastases with high HER-2/neu expression.
10.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.