1.Changes of Plasma Somatostatin in Children with Septic Shock
Ai-rong, HUANG ; Yi-mei, JIN ; Hao-mei, YANG
Journal of Applied Clinical Pediatrics 2006;0(22):-
Objective To explore the changes of plasma somatostatin(SST) in children with septic shock.Methods The level of plasma SST in children with septic shock (test group,n=21) on an empty stomach at shock stage,blood pressure and heart rate recovery stage,recovery stage(at that time clinical symptoms and signs disappeared,infection indicators such as blood routine and CRP returned to normal,about 6-12 days after admission) were detected by competive radioimmunassay,the level of SST in healthy children(healthy control group,n=25) on an empty stomach on morning was detected,too.The levels of plasma SST between septic shock concbined with paralytic ileus group and without paralytic ileus group were compared.Results 1.Level of plasma SST of test group at shock stage[(44.60?16.83) ng/L]was significantly lower than that of control group[(123.15?6.57) ng/L](t=-12.16 P0.05).The level of plasma SST of children with paralytic ileus [(28.10?7.0) ng/L] was significantly lower than that of children without paralytic ileus [(56.98?9.44) ng/L](t=-7.70 P
2.Studies on Establishing and Optimizing Conditions of Concentration Virus in Water Body
Bao-Jin PAN ; Jun-Yi LIU ; Mei-Liang WEI ;
Microbiology 1992;0(06):-
In this experiment six methods,calcium chloride(CaCl_(2)) precipitation,polyethylene glycol(PEG,pH7.0) precipitation,polyethylene glycol(PEG,pH11.5) precipitation,aluminum chloride(AlCl_(3)) precipitation,Amicon Utcra centrifugal filter devices and cellulose nitrate membrane were used to concentrate the vaccine poliovirus type 1(PV_(1)) added to water body;experimental conditions for concentration were selected and optimized.The results showed that two methods,CaCl_(2)and PEG(pH 7.0) precipitation were suitable for concentrating virus in large volumes of water while amicon utcra centrifugal filter devices for small ones.The virus recovery of the three methods reached a 100% rate.
3.Modified nasolacrimal duct stenting
Min TIAN ; Mei JIN ; Huanjun CHEN ; Yi LI
Journal of Interventional Radiology 2001;0(06):-
Objective Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting(100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting.
4.EFFECTS OF DAIDZEIN ON THE ENZYMES OF BONE METABOLISM AND BONE REBUILDING IN OVARIECTOMIZED RATS
Mei GAO ; Bangquan JIN ; Yi ZHANG ; Chen LIU
Acta Nutrimenta Sinica 1956;0(02):-
Obejective To study the effect of daidzein(Daid) on the enzymes of bone metabolism and bone rebuilding in ovariectomized rats.Method Sixty 3-mon female SD rats were divided into 6 groups:Sham,OVX,OVX-D1~D4 groups.Every day the rats in Sham and OVX groups were given distilled water,and the rats in OVX-D1,OVX-D2,OVX-D3,OVX-D4 groups were given 25,50,75,100 mg/kg bw Daid respectively.After 6 mon,all of rats were killed,and the blood,liver and femur were collected.The content of calcium and phosphorus in serum and the enzymes of bone metabolism were measured.Results The content of calcium,phosphorus and ATPase in serum was increased,but the activity of serum alkaline phosphatase(ALP) and tartrate-resistant acid phosphatase(TRAP-5b) was decreased dose-dependently in OVX-D groups compared with OVX group.Conclusion The expression of bone metabolism-associated enzymes could be inhibited,which resulted in inhibition of bone formation and absorbsion in ovariectomized rats.The new balance between bone formation and absorption could be rebuilt by Daid,through the mechanism of decreasing rate of bone conversion.
5.Effects of ginkgolide (Gin) on cerebral water content, Na+, K(+) -ATPase activity, MDA, lactic acid of rats during acute hypoxia condition.
Jian-Cheng LI ; Shu-Yi JIN ; Xiao-Mei WU
Chinese Journal of Applied Physiology 2003;19(3):239-273
Animals
;
Brain
;
metabolism
;
Female
;
Ginkgolides
;
pharmacology
;
Hypoxia
;
metabolism
;
Lactic Acid
;
metabolism
;
Male
;
Malondialdehyde
;
metabolism
;
Rats
;
Rats, Sprague-Dawley
;
Sodium-Potassium-Exchanging ATPase
;
metabolism
7.Preparation of pantoprazole sodium enteric-coated pellets-type tablets.
Mei-Mei CHEN ; Cheng-Run WANG ; Yi JIN
Acta Pharmaceutica Sinica 2011;46(1):96-101
This study is to prepare the pantoprazole sodium enteric-coated tablet which is compacted by pellets. The enteric-coated pantoprazole sodium pellets were prepared by fluid bed coating technology. The pantoprazole sodium enteric-coated tablets were prepared by direct compression of the enteric-coated pellets and suitable excipients. In vitro dissolution method and scanning electron microscope method were used for the observation of the drug release behavior before and after compression of the pellets. The optimized formulation is: the coating level is 55%, the plasticizer content is 20%, the ratio of Eudragit L30D-55/NE30D is 8 : 2, enteric-coated pellets/excipients (MCC/PPVP/PEG 6000 = 2 : 1 : 1) is 5 : 5, the enteric-coated tablets release in artificial gastric fluid in 2 h is less than 10%, while in artificial intestinal fluid in 1 h is more than 85%. The release behavior of pantoprazole sodium enteric-coated pellets-type tablet is quite well. And it may be used in industrial production.
2-Pyridinylmethylsulfinylbenzimidazoles
;
administration & dosage
;
chemistry
;
Chromatography, High Pressure Liquid
;
methods
;
Drug Carriers
;
Drug Compounding
;
methods
;
Excipients
;
Microscopy, Electron, Scanning
;
Plasticizers
;
chemistry
;
Polyethylene Glycols
;
chemistry
;
Polymethacrylic Acids
;
chemistry
;
Proton Pump Inhibitors
;
administration & dosage
;
chemistry
;
Solubility
;
Tablets, Enteric-Coated
;
chemistry
;
Technology, Pharmaceutical
8.Analysis of volatile constituents in two species of genus Magnolia by HS-SPME-GC-MS.
Lei SHI ; Jin-mei WANG ; Wen-yi KANG
China Journal of Chinese Materia Medica 2008;33(12):1429-1433
OBJECTIVETo analyze and compare the volatile constituents from M. biondii and M. liliflora.
METHODThe volatile constituents were extracted by head-space solid-phase microextraction, and analyzed by GC-MS.
RESULTSeventy two constituents were identified from M. biondii and M. liliflora, the content of the 25 constituents in both samples were similar, while the kinds of the constituents were obviously different.
CONCLUSIONThe volatile constituents were different between M. biondii and M. liliflora.
Drugs, Chinese Herbal ; chemistry ; isolation & purification ; Gas Chromatography-Mass Spectrometry ; Magnolia ; chemistry ; Solid Phase Microextraction ; Volatilization
9.Expression changes of Rhodopsin and recoverin in MNU-induced photoreceptor degeneration in rats
Wei, JIN ; Yi-Qiao, XING ; Hai-Feng, MEI ; Wen-Jun, WANG ; An-Huai, YANG
International Eye Science 2014;(10):1755-1759
AIM: To investigate the time - effect relationship between the expression of rhodopsin and recoverin and photoreceptor damage induced by N - nethl - N -nitrosourea ( MNU) .
METHODS: Thirty-six 7-week old Sprague-Dawley ( SD ) rats were intraperitoneally injected with MNU ( 60mg/kg ) and were put to death by dislocation of cervical vertebra 6, 12, 24h; 3, 7d after injection ( 6 per group) , respectively. As a control, six rats were injected with phosphate buffer saline (PBS) 5mL/kg and sacrificed on d3 after injection. The degree of photoreceptor apoptosis was detected by HE staining, terminal deoxynucleotidyl transferase-mediated dUTP nick end-labeling ( TUNEL ) and transmission electron microscope ( TEM ) in the right eyes. The mRNA expressions of rhodopsin and recoverin were detected different time after injection by Western blot and immunohistochemical method in the left eyes.
RESULTS:The dissolution of photoreceptor nucleus and apoptosis body were first perceived at 12h by TEM; most of cells at outer nuclear layer were presented positive reaction. The apoptotic index reached peak ( 29. 7% ±2.3%) at 24h which was coincided with the observation of TEM. The results of immunohistochemistry displayed that rhodopsin and recoverin were on a declining curve with time extension. Furthermore, the results of Western blot indicated that rhodopsin had dramatic decline at 6h after injection (P<0. 05), and extremely significant difference comparing to control group after 12h ( P<0. 01 ); while recoverin dramatic declined at 12h, and extremely significant difference after 24h (P<0. 01).
CONCLUSION:60mg/kg MNU intraperitoneally injection one - time may specifically induce photoreceptor apoptosis, The mechanism of down - regulation of rhodopsin and recoverin may be related to the selected apoptosis of photoreceptors.
10.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.