1.The design and application of fully automatic X-ray exposure control
Yi LIU ; Yong-Bo LIU ;
Chinese Journal of Radiology 2001;0(05):-
Objective To realize fully automatic X-ray exposure controlling,simplify operating processes,and improve the quality of images.Methods We designed 5 or 7 X-ray detectors with silicon batteries,improved film-holding board of the main engine of the X-ray machine,then assembled them by mechanical gearing,and thus made multi-measured-limit,automatically-changed X-ray detectors.Results When choosing film boxes according to the radiographed positions,the detectors will change automatically into measured-limits coinciding with the interested positions.The average density was around 1Ⅴ in 9 randomly selected photographs.High quality was achieved in up to 98% of 10 000 radiographed images for clinic radiography.Conclusion The key of X-ray automatic exposure controlling technology is X-ray detecting technology,by which the quality of image can be improved.
2. Phospholipase C signaling pathway and M channel modulation
Academic Journal of Second Military Medical University 2006;27(10):1138-1141
As an outward, voltage-dependent potassium channel, M type channel is crucial in the regulation of neuronal excitability; it is modulated by a variety of factors in vivo and its dysfunction often results in neuronal system diseases. Great efforts have been made to elucidate the mechanism underlying M channel modulation since its discovery decades ago. It is generally accepted that the Phospholipase C (PLC) signaling pathway plays a significant role in the M channel modulation. This review highlights the relationship between PLC signaling pathway and M channel modulation, as well as some recent progresses in the research of this field.
3.Short-term outcome of stent-assisted angioplasty for extracranial carotid stenosis
Bo HONG ; Jianmin LIU ; Yi XU
Journal of Interventional Radiology 1994;0(03):-
Objective To evaluate the safety and short term outcome of stent assisted angioplasty for extracranial carotid stenosis. Methods From October 2000 to September 2002, 93 cases of extracranial carotid stenosis, including 86 cases of carotid bifurcation stenoses, 4 of extracranial internal carotid stenoses, 2 of common carotid stenoses and 1 of functional external carotid stenosis, were treated by self expandable stent placement and angioplasty. Results Stent placement and angioplasty were successfully administered in all the 93 patients. The average stenosis rate was reduced from (79.5?14.6)% before treatment to (11.2?7.8)% after stent assisted angioplasty. There were only 1 case of TIA (1.1%) and 1 case of minor stroke (1.1%) during the operation, without mortality or major stroke. No cerebral ischemic attach occurred in the 91 patients during clinical follow up for a period of 3 25 months with an average of 7.9 months. Twenty nine patients were angiographically followed up 6 months after treatment with only one asymptomatic restenosis (3.4%). Conclusions Endovascular stent assisted angioplasty for extracranial stenosis is safe and effective with considerable good short term outcome.
4.Clinical study of endovascular stenting combined with coiling for treatment of intracranial wide-necked aneurysms
Jianmin LIU ; Yi XU ; Bo HONG
Journal of Interventional Radiology 1994;0(03):-
Objective To report experience of endovascular stenting combined with coiling for intracranial wide necked aneurysms and to investigate its indication, technical tip, prevention and treatment of complication, safety and efficacy. Methods The coronary stents were implanted across the neck of intracranial wide necked aneurysms in 105 patients (78 located in anterior circulation and 27 in posterior circulation). Microcatheters were introduced into the aneurysm sac through stent mesh. GDCs were used to embolize the aneurysms . Results The stents were deployed in 104 patients and total occlusion was obtained in 80 cases and more than 90% in 24 cases. The patients recovered well with patency of the parent arteries except one with cerebral infarction and another with carotid dissection during the procedure. The stent collapsed in one case after coiling.No re bleeding or symptom related to thrombosis occurred during clinical follow up for 3 28 months. Follow up angiogram in 62 cases showed no recanalization in all patients, but two with further thrombosis and one with mild stenosis in proximal segment of the stent. Conclusions Endovascular therapy combined stent implantation and microcoil placement would be a valid alteration for the treatment of complicated intracranial aneurysms. However, long term outcome need further study.
5.Treatment of anterior communicating artery aneurysms with Guglielmi detachable coils
Yi XU ; Jianmin LIU ; Bo HONG
Journal of Interventional Radiology 1994;0(03):-
90%) and partial in 46 (
6.Endovascular treatment of intracranial aneurysms with stents and coils
Jianmin LIU ; Bo HONG ; Yi XU
Journal of Interventional Radiology 1994;0(04):-
Objective Endovascular stenting or combined stenting and Guglielmi detachable coils packing for the treatment of intracranial fusiform and wide necked aneurysms were reported to access the feasibility of the procedures.Methods The coronary stents were implanted across the neck of 3 vertebral fusiform aneurysms and 6 wide necked aneurysms. Microcatheters were introduced into the aneurysm sacs through stent mesh, and finally GDCs were used to embolize the aneurysms. Results The stents were precisely deployed resulting in total occlusion of 7 cases with more than 90% occlusion in 2 cases. All patients recovered well with patency of the parent arteries.Conclusions Endovascular therapy with combined stent implantation and microcoil placement maybe a valid alteration for the treatment of intracranial fusiform or wide necked aneurysms.
7.Rupture during procedure for intracranial aneurysm embolization with GDC
Yi XU ; Jianmin LIU ; Bo HONG
Journal of Interventional Radiology 1992;0(01):-
Objective To analyze the causes, prevention and treatment of repture druing procedure for intracranial aneurysm embolization with GDC.Methods All the seven patients were embolized. Six patients were ruptured during the procedure and continuously embolized until the bleeding was halted. Another one was identified by post procedure CT. Results Four patients recovered unevent fully with one only suffering from mild deficit. Another 2 patients died of hyper intracranial pressure within one week. Conclusions Rupture during procedure of intracranial aneurysm embolization with GDC may be related to manipulation, properties of the parent artery and arneurysm. Continuous embolization with GDC will provide favorable prognosis for the patients.
8.Endovascular treatment of large and giant ophthalmic aneurysms with preservation of parent artery
Yi XU ; Jianmin LIU ; Bo HONG
Journal of Interventional Radiology 1992;0(01):-
Objective To evaluate the endovascular embolization treatment of large and giant ophthalmic aneurysms. Methods Three aneurysms were embolized with coils only and 5 aneurysms were treated with stent placement togather with subsequent coiling. Results In the 3 aneurysms treated only with GDC, total embolization was achieved in 1 and partial embolization in 2. In the stent placement and coiling case, 4 aneurysms were densely packed and another one was partially packed. Conclusions Combined stenting and coiling is effective and safe for the treatment of large and giant ophthalmic artery aneurysm with the preservation of parent artery.
10.Symptomatic cerebral vasospasm after early treatment of acutely ruptured aneurysms by endovascular embolization
Bo HONG ; Jianmin LIU ; Yi XU
Journal of Interventional Radiology 2003;0(S1):-
Objective We analyzed the incidence and treatment of symptomatic vasospasm after early endovascular therapy of ruptured aneurysms by endovascular embolization.Methods 329 patients classified as Hunt-Hess grades Ⅰto Ⅲ were embolized within 72 hours after aneurysm rupture. Symptomatic vasospasm was diagnosed as the onset of delayed neurological deterioration with evidence of angiographic or transcranial Doppler studies. Results Symptomatic vasospasm occurred in 62 patients (18.2%). Both Hunt-Hess grade and Fisher's scale before treatment correlated with the incidence of cerebral vasospasm. Among the 62 patients suffered from symptomatic vasospasm, 41 patients recovered well, 13 were moderately disabled, 6 were severely disabled and 2 patients died. Conclusions The incidence of symptomatic vasospasm was relatively low as compared to conventional open surgery. lumber puncture cerebral spinal fluid drainage may play an important role in reducing the incidence of cerebral vasospasm.