1.A Review on Researches on Resiliency Abroad
Chinese Journal of Clinical Psychology 2006;0(05):-
Resiliency is individual's capability to cover difficulties and make a good adaptation.This research reviews the researches on resiliency abroad.It summarizes the practical researches of resiliency from 3 aspects: ① The concept of resiliency;②The structure and intension of resiliency;③The measurement of resiliency.On this basis,it raises some questions in resiliency researches and puts forward the future direction.
3.A Pharmacodynamic Study of Penyan Qing Capsule
Biqiong SHEN ; Yi SITU ; Yongquan OU
Journal of Guangzhou University of Traditional Chinese Medicine 1999;0(02):-
Objective To explore the main pharmacological actions of Penyan Qing Capsule (PQC) for chronic pelvic inflammation. Methods The analgesic action of PQC was studied by mouse hot_plate method. Experiments of mouse auricular swell ing and rat agar_induced granuloma were carried out to investigate the anti_infl ammatory action of PQC. Effects of PQC on function of mouse mononuclear phagocyt es and rat mesenteric microcirculation were also studied. Results PQC increa sed the rat pain threshold, reduced mouse auricular swelling induced by xylene a nd the weight of rat agar_induced granuloma. PQC could also improved rat mesente ric microcirculation disorder induced by noradrenline and increase the function of mouse mononuclear phagocytes. Conclusion PQC exerts good anti_inflammatory and analagisic action and can improve microcirculation. This will supply pharm acodynamic evidence for the application of PQC in clinic.
4.Report of a case with long time persisted esophagus foreign associated with hoarse.
Lin GAO ; Wan-rong LI ; Xiao-yi OU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2010;45(9):772-772
Aged
;
Esophagus
;
Foreign Bodies
;
complications
;
diagnosis
;
Hoarseness
;
diagnosis
;
etiology
;
Humans
;
Male
5.The influence of non-ablating ultrasound pre-exposure on the efficacy of high intensity focused ultrasound in ablating VX2 liver tumors
Yan WANG ; Xia OU ; Hairong ZOU ; Jianzhong ZOU ; Yi ZHANG
Chinese Journal of Physical Medicine and Rehabilitation 2011;33(3):171-174
Objective To assess the influence of pre-exposure to non-ablating ultrasound on the effect of high intensity focused ultrasound(HIFU)ablation.Methods Forty rabbits with transplanted VX2 tumors on their livers were divided into three pre-exposure groups(60 W,80 W and 100 W)and a control group(O W),with 10 rabbits in each group.Each group was pre-exposed to lower intensity focused ultrasound at the corresponding power.From each group,5 rabbits were randomly selected to be exposed to HIFU on the next day.Each group received 14scans.The rabbits were sacrificed 24 h later to take tissue samples for tfipheny tetrazolium chloride(TTC)staining to measure the amount of coagulative necrosis.Hematoxylin and eosin(HE)staining and succinate dehydrogenase (SDH)were also measured to observe the structure and activation of pre-exposed tumors.Results After HIFU exposure,the ablated volumes increased with pre-exposure acoustic intensity,and all volumes were larger than those in the control group.The ablating efficiency in the 100 W group was the highest.The pre-exposure did not itself ablate tumor tissue,but in the 80 W and 100 W groups the structure and activation of the tissues changed.Those in the 60 W group were not obviously altered.Conclusion Prior exposure to non-ablating ultrasound can highly enhance the efficacy of HIFU ablation.
6.Study of stabilization of the enzyme activity of ALT and the matrix effects of betaine
Yuanzhu OU ; Yi JU ; Liping TANG ; Meijuan WANG ; Xiaoxuan YU
Chinese Journal of Laboratory Medicine 2011;34(2):175-178
Objective To investigate the stabilization of betaine on the enzyme activity of ALT in human serum at different temperatures, and to evaluate the matrix effects of human serum with betaine among different analytical systems. Methods The enzyme activity of ALT in human serums with l mol/L betaine stored at 37 ℃, 25 ℃, 4 ℃ and - 20 ℃ respectively were measured. The matrix effect experiment was carried out according to the procedures specified in Clinical and Laboratory Standards Institute (CLSI)document EP14-A. Four analytical systems were the candidates for evaluation, and Roche Diagnostics (Roche)-Hitachi analytical system served as the reference system. The enzyme activity of ALT of 40 patient specimens and 3-level specimens ( high, medium and low) with 1 mol/L betaine were measured using the evaluated methods and the reference method respectively. The linear regression analysis was performed to compare the mean y value of 3-level specimens with the statistically defined limits ( the two-tailed 95% prediction interval) derived from 40 patient specimen data. Results The enzyme activity of ALT could be stabilized with betaine in serum, which remained to be 99% for 48 h at 37 ℃, 98% for4 d at 25 ℃, 97%for 4 weeks at 4 ℃, and 99% for 4 months at - 20 ℃. The enzyme activity of control serum decreased to 42%, 86%, 71%, 79% respectively. The mean y values of three specimens with the betaine were within the 95% prediction interval of the estimated mean y values, which suggested no obvious matrix effects in serum. Conclusion Betaine can be used in the development of enzyme ALT calibrator as its stabilizer.
7.Prenatal ultrasound screening for fetal cleft lip and palate and related abnormalities
Li ZHEN ; Xin YANG ; Cuixing YI ; Yanmei OU ; Dongzhi LI
Chinese Journal of Perinatal Medicine 2012;15(9):543-546
Objective To evaluate the sensitivity and specificity of prenatal ultrasound for detecting fetal cleft lip and palate,and the diagnosis rate of associated congenital structural and chromosomal abnormalities.Methods Thirty one thousand two hundred and forty five singleton pregnant women accepted prenatal examination and delivered in Guangzhou Women & Children' s Medical Center from Jan.2006 to Dec.2010 were recruited in this study.All pregnant women underwent prenatal ultrasound screening during second trimester,and whose fetuses were suspected to be cleft lip and palate were suggested to accept karyotype analysis.All babies delivered received oral examination to diagnose cleft lip and palate.Results Cleft lip and palate was diagnosed in 48 cases (1.5‰,48/31 245).Among which,there were 16 cases (33.3%,16/48) of cleft lip,21 cases (43.8%,21/48) of cleft lip with cleft palate and 11 cases (22.9%,11/48) of cleft palate.Prenatal ultrasound screening suggested 18 cases of cleft lip and 14 cases were comfirmed after birth with the accuracy rate of 77.8%,3 cases were diagnosed to be cleft lip with cleft palate and one cases was misdiagnosed.Prenatal ultrasound screening suggested 18 cases of cleft lip with cleft palate in accordance with the diagnosis after birth.Thirteen cases were normal in prenatal ultrasound screening,but two were diagnosed as cleft lip and 11 were diagnosed as cleft palate after birth.The sensitivity of prenatal ultrasound screening for cleft lip and cleft lip with cleft palate was 86.5%(32/37),and the sensitivity for cleft lip and palate was 66.7% (32/48),the false positive rate was 2.1% (1/48).Ten cases (27.8%,10/36) of cleft lip with cleft palate were found to be complicated with other abnormalities.Nine of the 18 cases prenatally diagnosed cleft lip with cleft palate accepted karyotype analysis and 7 were abnormal.Twenty-three of 36 cases with fetal cleft lip and palate in prenatal ultrasound screening were induced.Conclusions Ultrasound screening has a high sensitivity for detection of cleft lip with or without cleft palate,but difficult to detect cleft palate.The risk of combining with chromosomal defects in cleft lip fetus is very low,but might increase once associated with cleft palate.
8.Curative Effect of Underatured Lactalbumin Treatment in Children with Nephrotic Syndrome
cheng, ZHANG ; bin, LI ; yu-ling, XIAN ; xing-yi, OU
Journal of Applied Clinical Pediatrics 1992;0(05):-
Objective To investigate the clinical efficacy of nephrotic syndrome in children adjunctively treated by underatured lactalbumin.Methods Thirty-six cases of nephrotic syndrome were studied for about 1 year.The changes in red blood cells of reduced glutathione(GSH) were analyzed in 18 cases of underatured lactalbumin treatment group and 18 cases of control group.The clinical presentations were observed in both groups.Results GSH levels increased in underatured lactalbumin treatment group when compared with control group.The frequency of relapse and upper respiratory tract infection in underatured lactalbumin treatment group were significantly reduced compared with control group.Conclusion Underatured lactalbumin can provide support for the potential use of an antioxidant therapy in these patients.
9.High viscosityversus common viscosity bone cement systems in the treatment of osteoporotic vertebral compressive fractures:a Meta-analysis
Xiaoping MU ; Weilin YI ; Jianxun WEI ; Yufu OU ; Zhuhai LI
Chinese Journal of Tissue Engineering Research 2017;21(2):322-328
BACKGROUND:Vertebroplasty system has been proved to be effective for osteoporotic vertebral compressive fracture (OVCF); however, bone cement leakage-related complications occur frequently. Thereafter, high-viscosity bone cement system with high safety and efficacy is developed, but there is stil a lack of large-scale and high quality research. OBJECTIVE:To systematicaly review the efficacy and safety of high viscosityversus common bone cement systems for OVCF. METHODS: PubMed, Embase, Cochrane Library, CNKI, CqVip and WanFang databases were searched to colect the literatures about randomized controled trials (RCTs) or clinical controled trials (CCTs) of high viscosityversus common bone cement systems for OVCF published before January 2016. The quality assessment of included literatures and data extraction were performed by two researchers independently according to the Cochrane system. Data analysis was conducted using RevMan 5. 2 software. RESULTS AND CONCLUSION:Four RCTs and six CCTs were enroled. The results of Meta-analysis indicate that there were no significant differences in the volume of bone cement [MD=0.17, 95%CI(-0.04, 0.38)], visual analogue scale scores [RCT:MD=-0.30, 95%CI(-0.72, 0.11); CCT:MD=-0.05, 95%CI(-0.43, 0.32)] and incidence of second fractures [OR=1.77, 95%CI(0.24, 12.86)] between two bone cements. However, patients undergoing high viscosity bone cement system have significantly lower Oswestry disability index scores [MD=-2.99, 95%CI(-5.85,-0.13)], greater recovery of Cobb angle [MD=-3.19, 95%CI(-5.27,-1.10)] and lower incidence of cement leakage [OR=0.35, 95%CI(0.24, 0.51)]. High viscosity bone cement system in the treatment of OVCF shows good results at recovery of spinal structure and function and reducing leakage. Due to the limited quantity of included literature sand high heterogeneity, more large scale and high quality RCTs are stil needed for further verification.
10.Pathological regression of rabbit liver after low-dose irradiation with high intensity focused ultrasound
Yi ZHANG ; Jianzhong ZOU ; Xia OU ; Hairong ZOU ; Yan WANG
Chinese Journal of Medical Imaging Technology 2010;26(4):620-622
Objective To observe the pathological regression of rabbit liver after the low-dose irradiation with high intensity focused ultrasound (HIFU), and to explore the role and mechanism of the irradiation in changing acoustic environment of rabbit liver. Methods Pathological study was performed in 10 New Zealand white rabbits, the livers were observed under light and electron microscope. The observation was done immediately after low-dose HIFU irradiation and in 2, 3, 5, 7 days after the low-dose irradiation with HIFU. Results Light microscope changes: Edema existed in hepatocytes after irradiation instantly, congestion and aggravated edema were found at 2-3 days, then the injured cells recovered gradually. Electron microscope changes: Detached endothelial cells of hepatic sinusoid and swelling organelles were observed after irradiation, while 2 or 3 days later, erythrocyte aggregation was found in hepatic sinusoid and cavitation was found in cytoplasm. Thereafter, organelles swelling reduced till resumed to normal. Conclusion Low-dose HIFU irradiation can make corresponding changes to the acoustic environment of rabbit liver.