1.A Irreducible Ankle Fracture and Dislocation Due to Injured Tibialis Posterior Tendon Interposition: A Case Report.
Jun Young LEE ; Yi Gyu BAK ; Hyun Woong JANG
Journal of Korean Foot and Ankle Society 2017;21(2):70-74
Fractures and fracture-dislocations of the ankle are caused by a variety of mechanisms. In addition to fractures, injuries of soft tissue, such as ligaments, tendons, nerves, and muscles may also occur. Among these, a tibialis posterior tendon injury is difficult to be identified due to swelling and pain at the fracture site. It is difficult to observe tibialis posterior tendon injury on a simple radiograph; it is usually found during surgery by accident. There are some studies regarding irreducible ankle fracture-dislocations due to interposition of the tibialis posterior tendon; however, to the best of our knowledge, there has not been any report about interposition of injured tibialis posterior tendon. Herein, we report a case of an irreducible fracture-dislocation of the ankle due to injured tibialis posterior tendon interposition that was observed intraoperatively, interrupting the reduction of ankle fracture-dislocation. We obtained satisfactory clinical result after reduction of the trapped tendon, fracture reduction, and internal fixation; therefore, we are willing to report this case with the consent of the patient. This study was conducted with an approval from the local Institutional Ethics Review Board.
Ankle Fractures*
;
Ankle*
;
Dislocations*
;
Ethics, Institutional
;
Humans
;
Ligaments
;
Muscles
;
Tendon Injuries
;
Tendons*
2.Calcaneal Apophyseal Avulsion Fractures with Achilles Tendon Rupture in a 10-Year-Old Patient: A Case Report.
Jun Young LEE ; Yi Gyu BAK ; Jae Hwan LIM
Journal of Korean Foot and Ankle Society 2018;22(2):74-77
Calcaneal apophysitis is a relatively common disease in young athletes. On the other hand, if not treated properly, it can lead to apophyseal avulsion fracture in rare cases. In the case of apophyseal avulsion fractures, it is often necessary to remove or preserve the bone fragment, which often requires a suture of the Achilles tendon. A 10-year-old badminton athlete visited the outpatients' clinic with pain in both heels from 10 months ago without any trauma history. After conservative therapy, the pain in the left heel was relived but the right heel pain persisted. After 10 months of conservative therapy, the patient visited the outpatients' clinic showing a calcaneal apophyseal avulsion fracture with a total rupture of the Achilles tendon. In the operation room, a bone fragment needed to be removed because of its poor viability and the fragment was too thin for fixation. After removing the bone fragment, the ruptured Achilles tendon was fixed with an anchor system.
Achilles Tendon*
;
Athletes
;
Child*
;
Hand
;
Heel
;
Humans
;
Racquet Sports
;
Rupture*
;
Sutures
3.Efficacy of 3D-Printed Titanium Mesh-Type Patient-Specific Implant for Cranioplasty
Hong-Gyu YOON ; Yong KO ; Young-Soo KIM ; Koang-Hum BAK ; Hyoung-Joon CHUN ; Min-Kyun NA ; Sook YANG ; Hyeong-Joong YI ; Kyu-Sun CHOI
Korean Journal of Neurotrauma 2021;17(2):91-99
Objective:
Autologous bone grafting for cranioplasty is associated with a high infection rate and bone absorption. Synthetic implant materials for cranioplasty have been developed. In this study, we evaluated the efficacy of titanium mesh-type patient-specific implants (PSIs) for patients with skull defects using the dice similarity coefficient (DSC), clinical outcomes, and artifacts caused by implants.
Methods:
This retrospective study included 40 patients who underwent cranioplasty with a titanium mesh PSI at our institution. Based on preoperative and postoperative computed tomography scans, we calculated DSC and artifacts.
Results:
The calculated DSC of 40 patients was 0.75, and the noise was 13.89% higher in the region of interest (ROI) near the implanted side (average, 7.64 hounsfield unit [HU]±2.62) than in the normal bone (average, 6.72 HU±2.35). However, the image signal-to-noise ratio did not significantly differ between the ROI near the implanted side (4.77±1.78) and normal bone (4.97±1.88). The patients showed no significant perioperative complications that required a secondary operation.
Conclusion
Titanium mesh-type PSIs for cranioplasty have excellent DSC values with lower artifacts and complication rates.