1.Clinical observation of 31 patients of congenital ectopia lentis treated with different operative manipulations
Mei-Fang, CHU ; Qian, ZHANG ; Fang, CHAI ; Cong-Yi, WANG
International Eye Science 2016;16(10):1929-1932
AIM: To determine the optimal operation method and reduce operative complications by retrospective analysis of outcomes of different operative manipulation for patients with congenital ectopia lentis ( CEL) .
●METHODS: A retrospective study ranged from Jan. 1, 2010 to Jan. 1, 2015 was conducted and 31 CEL patients (57 eyes) treated with different operations were taken into this study. The postoperative outcome, operation related complications was analyzed in terms of different operative manipulations.
● RESULTS: The most common types of CEL are idiopathic and Marfan - related CEL. All eyes ( 98%) benefited from operation except 1 Marchesani syndrome eye concurrent with optic atrophy induced by glaucoma. A total of 3 eyes ( 5%) were treated by phacoemulsification combined with intraocular lens implantation; 8 eyes ( 14%) were treated by phacoemulsification, capsular tension ring implantation combined with intraocular lens implantation, among these 8 eyes, 1 eye was treated with capsular tension ring implantation combined with suture fixation; 39 eyes ( 68%) were treated by lens excision and anterior vitrectomy through corneal incision combined with intraocular lens implantation with suture fixation, among these 39 eyes, 2 eyes were treated with trabeculectomy , but not combined with intraocular lens implantation; 5 eyes ( 9%) were treated by intracapsular cataract extraction and anterior vitrectomy combined with intraocular lens implantation with suture fixation; 2 eyes ( 4%) were treated by lens excision and vitrectomy through pars plana combined with silicon oil injection.
● CONCLUSION: Almost all patients can obtain satisfactory outcomes through various operative manipulations. Phacoemulsification combined with intraocular lens implantation was the first choice for patients with lens dislocation range less than 90°. Phacoemulsification, capsular tension ring implantation combined with intraocular lens implantation was recommended for 90° - 180°, and lens excision and anterior vitrectomy through corneal incision combined with intraocular lens implantation with suture fixation was more suitable for lens dislocation range more than 180°. The appropriate operative methods for different types of CEL patients is the key to success.
3.Forty cases of chronic prostatitis/chronic pelvic pain syndrome treated by acupuncture and crude herb moxibustion.
Yi-mei BAO ; Fang LUO ; Jian-hua WEI
Chinese Acupuncture & Moxibustion 2011;31(6):571-572
Acupuncture Therapy
;
Adult
;
Chronic Disease
;
therapy
;
Humans
;
Male
;
Moxibustion
;
Pelvic Pain
;
therapy
;
Prostatitis
;
therapy
;
Treatment Outcome
;
Young Adult
4.Development history of methodology of Chinese medicines' authentication.
Ke-Li CHEN ; Lin-Fang HUANG ; Yi-Mei LIU
China Journal of Chinese Materia Medica 2014;39(7):1203-1208
This paper reviewed the emergence process of the subject and methodology of Chinese Medicines' Authentication. Based on the research progress and major achievements acquired in research of each methodology including identification of origin, description, microscopic, physical, chemical and biological characteristics of Chinese medicines, it is expounded that the development process of each methodology combined modem digital technology, information science and its own characteristics. And the development direction is further described for methodology of Chinese Medicines' Authentication towards systematization and informationization.
Chemistry, Pharmaceutical
;
history
;
methods
;
Drug Contamination
;
prevention & control
;
Drugs, Chinese Herbal
;
chemistry
;
history
;
pharmacology
;
History, 20th Century
;
History, 21st Century
;
Quality Control
6.Clinical evaluation of Nickel-Titanium rotary instruments in preparation of root canals
Chun-Mei YU ; Yi-Yun FANG ; Xue-Xun WU ;
Chinese Journal of Primary Medicine and Pharmacy 2006;0(12):-
Objective To study and assess clinical application of two Nickel-Titanium(NiTi)rotary instru- ments,namely ProTaper and Hero 642,in preparation of root canals.Methods 125 teeth were divided into three groups and respectively instrumented by stainless K-files,ProTaper or Hero 642 rotary instruments.All teeth were obturated with lateral condensation method.The efficiency of preparation and obturation was analyzed with radio- graphs.Results NiTi rotary instruments were better in keeping the curvature and flow of curved canals than stain- less K files.There was no transportation,apical blockage and ledge in NiTi groups.The operative time was shorter and endodontic flare-up seldom occurred in NiTi groups.Conclusion The NiTi rotary instrumentation technique could be used to prepare curved root canals effectively and quickly.The future use of NiTi engine-driven rotary in- strument appeared to be promising.
7.Effects of age and sex on circadian rhythms of renin-angiotensin system.
Mei LIU ; Yi-Fang GUO ; Lian-Ying NIU ;
Chinese Journal of Practical Internal Medicine 2006;0(S2):-
Objective To study the effect of age and sex on circadian rhythms of renin-angiotensin system(RAS) .Methods 96 SPRD rats were divided into three groups.The levels of renin(Ren)activity,angiotensin Ⅱ(Ang Ⅱ)and angiotensin-converting-enzyme(ACE)in plasma or serum were respectively determined.Results The plasma or serum levels of renin,ACE,and angiotensin-Ⅱ in adult male group(D group)were significantly increased in comparison with elderly male group(M group)and elderly female group(F group).There were not significantly different between F group and M group in the levels of Ren activity,AngⅡ and ACE.The three substances presented typical circadian rhythms in three groups(P
9.Inhibitory and dispersive effects of betaine on formation of Staphylococcus aureus biofilm
Fei JIN ; Yi WEN ; Yuqiao XU ; Yaning MEI ; Wenying XIA ; Jue WANG ; Fang NI
Chinese Journal of Clinical Laboratory Science 2017;35(4):261-263
Objective To observe the formation of Staphylococcus aureus biofilm and the inhibitory and dispersive effects of betaine on the biofilm.Methods The inhibitory and dispersive effects of 0.1% betaine on the biofilm from 20 strains of Staphylococcus aureus were examined by crystal violet assay.Results All the 20 strains of Staphylococcus aureus formed biofilm.The biofilm of methicillinsensitive Staphylococcus aureus (MSSA) was formed in 24 hours with peak value of absorbance (A590 nm) (1.99 ± 0.53).The biofilm of methicillin-resistant Staphylococcus atureus(MRSA) was formed in 48 hours with peak value of absorbance(A590 nm) (1.13 ±0.47).After adding betaine,the absorbance(A590 nm) of MSSA biofilm fell down to(1.74 ± 0.61) in 24 hours,while the absorbance(A590 nm) of MRSA biofilm fell down to(0.40 ± 0.12) in 48 hours,which was significantly reduced compared with the controls (t =2.43,5.84,P < 0.05 respectively).When adding betaine after the biofilm formed,the absorbancies (A590 nm) of both MSSA and MRSA showed no significant difference compared with the controls (P > 0.05).Conclusion Betaine could inhibit biofilm formation of Staphylococcus aureus at concentration of 0.1%,but it could not disperse the mature biofilm of Staphylococcus aureus.
10.Programmable multichannel electrophysiological stimulator based on MCU and CPLD platform.
Yi ZHENG ; Xiao-Mei WU ; Zu-Xiang FANG
Chinese Journal of Medical Instrumentation 2008;32(1):32-39
According to the instruction of the operator, the designed programmable multichannel stimulator will deliver stimuli with an assigned amplitude and a proper width to the electrode-array in various modes. Each stimulation time is controlled by the internal timer of the MCU, while the stimulated electrodes' spatial parameter is controlled by the CPLD. Having abandoned conventional isolation using the transformer, we have adapted optical coupling and stable float ground connection to achieve the safety standard required by physiological measurements.
Electric Stimulation
;
instrumentation
;
methods
;
Electric Stimulation Therapy
;
instrumentation
;
Electrodes, Implanted
;
Electrophysiology
;
instrumentation
;
methods