1.Accuracy of Ultrasound-Guided and Non-ultrasound-Guided Botulinum Toxin Injection Into Cadaver Salivary Glands.
Jae In SO ; Dae Heon SONG ; Joo Hyun PARK ; Eunseok CHOI ; Jung Yoon YOON ; Yeonji YOO ; Myung Eun CHUNG
Annals of Rehabilitation Medicine 2017;41(1):51-57
OBJECTIVE: To compare the accuracy of ultrasound (US)-guided and non-US-guided botulinum toxin (BTX) injection into the salivary glands (parotid and submandibular glands) of cadavers. METHODS: Two rehabilitation physician injected dye into three sites in the salivary glands (two sites in the parotid gland and one site in the submandibular gland) on one side of each cadaver (one was injected on the right side, while the other was injected on the left side), using either a non-US-guided injection procedure based on superficial landmarks or a US-guided procedure. Orange dye was used for the US-guided procedure, and green dye was used for the blind procedure. Two physicians uninvolved with the injection procedures and who were blinded to the method of injection dissected the cadavers to identify whether the dye was accurately injected into each target site. RESULTS: The accuracies of the blind and US-guided injections into the parotid gland were 79.17% and 95.83%, respectively. In the submandibular gland, the accuracies of the blind and US-guided injections were 50.00% and 91.67%, respectively. The difference in accuracy between the two procedures was statistically significant only in the submandibular gland (p=0.025). There were no significant differences in the accuracy of US-guided and non-US-guided injections between the two physicians for the two sites in the parotid gland (p=0.278 and p=0.146, respectively). CONCLUSION: US-guided BTX injection into the submandibular gland offers significantly greater accuracy over blind injection. For the treatment of drooling by injecting BTX into the submandibular gland, clinicians should consider using US guidance for improved accuracy.
Botulinum Toxins*
;
Cadaver*
;
Citrus sinensis
;
Methods
;
Parotid Gland
;
Rehabilitation
;
Salivary Glands*
;
Sialorrhea
;
Submandibular Gland
;
Ultrasonography
2.Investigation of the Diagnostic Value of Ultrasonography for Radial Neuropathy Located at the Spiral Groove.
Seojin SONG ; Yeonji YOO ; Sun Jae WON ; Hye Jung PARK ; Won Ihl RHEE
Annals of Rehabilitation Medicine 2018;42(4):601-608
OBJECTIVE: To determine a diagnostic cut-off value for the cross-sectional area (CSA) of the radial nerve using ultrasonography for radial neuropathy located at the spiral groove (SG). METHODS: Seventeen patients with electrodiagnostic evidence of radial neuropathy at the SG and 30 healthy controls underwent ultrasonography of the radial nerve at the SG . The CSAs at the SG were compared in the patient and control groups. The CSA at the SG between the symptomatic and asymptomatic sides (ΔSx–Asx and Sx/Asx, respectively) were analyzed to obtain the optimal cut-off value. The relationship between the electrophysiological severity of radial neuropathy and CSA was also evaluated. RESULTS: Among the variables examined, there were statistically significant differences in the CSA between the patient and control groups, ΔSx–Asx, and Sx/Asx at the SG. In a receiver operating characteristics analysis, the cut-off CSA was 5.75 mm² at the SG (sensitivity 52.9%, specificity 90%), 1.75 mm² for ΔSx–Asx (sensitivity 58.8%, specificity 100%), and 1.22 mm² for Sx/Asx (sensitivity 70.6%, specificity 93.3%) in diagnosing radial neuropathy at the SG. There was no significant correlation between CSA and electrophysiological severity score for either patient group. CONCLUSION: The reference value obtained for CSA of the radial nerve at the SG may facilitate investigation of radial nerve pathologies at the SG.
Diagnostic Imaging
;
Humans
;
Pathology
;
Radial Nerve
;
Radial Neuropathy*
;
Reference Values
;
ROC Curve
;
Sensitivity and Specificity
;
Ultrasonography*