1.Hypoglycemic Effect and Mechanism of ICK Pattern Peptides
Lin-Fang CHEN ; Jia-Fan ZHANG ; Ye-Ning GUO ; Hui-Zhong HUANG ; Kang-Hong HU ; Chen-Guang YAO
Progress in Biochemistry and Biophysics 2025;52(1):50-60
Diabetes is a very complex endocrine disease whose common feature is the increase in blood glucose concentration. Persistent hyperglycemia can lead to blindness, kidney and heart disease, neurodegeneration, and many other serious complications that have a significant impact on human health and quality of life. The number of people with diabetes is increasing yearly. The global diabetes prevalence in 20-79 year olds in 2021 was estimated to be 10.5% (536.6 million), and it will rise to 12.2% (783.2 million) in 2045. The main modes of intervention for diabetes include medication, dietary management, and exercise conditioning. Medication is the mainstay of treatment. Marketed diabetes drugs such as metformin and insulin, as well as GLP-1 receptor agonists, are effective in controlling blood sugar levels to some extent, but the preventive and therapeutic effects are still unsatisfactory. Peptide drugs have many advantages such as low toxicity, high target specificity, and good biocompatibility, which opens up new avenues for the treatment of diabetes and other diseases. Currently, insulin and its analogs are by far the main life-saving drugs in clinical diabetes treatment, enabling effective control of blood glucose levels, but the risk of hypoglycemia is relatively high and treatment is limited by the route of delivery. New and oral anti-diabetic drugs have always been a market demand and research hotspot. Inhibitor cystine knot (ICK) peptides are a class of multifunctional cyclic peptides. In structure, they contain three conserved disulfide bonds (C3-C20, C7-C22, and C15-C32) form a compact “knot” structure, which can resist degradation of digestive protease. Recent studies have shown that ICK peptides derived from legume, such as PA1b, Aglycin, Vglycin, Iglycin, Dglycin, and aM1, exhibit excellent regulatory activities on glucose and lipid metabolism at the cellular and animal levels. Mechanistically, ICK peptides promote glucose utilization by muscle and liver through activation of IR/AKT signaling pathway, which also improves insulin resistance. They can repair the damaged pancrease through activation of PI3K/AKT/Erk signaling pathway, thus lowering blood glucose. The biostability and hypoglycemic efficacy of the ICK peptides meet the requirements for commercialization of oral drugs, and in theory, they can be developed into natural oral anti-diabetes peptide drugs. In this review, the structural properties, activity and mechanism of ICK pattern peptides in regulating glucose and lipid metabolism were summaried, which provided a reference for the development of new oral peptides for diabetes.
2.Evaluation of nutritional value of three kinds of medicinal snakes based on content of 15 amino acids.
Xi WANG ; Ye-Yuan LIN ; Wen-Ting ZHONG ; Zhi-Guo MA ; Meng-Hua WU ; Hui CAO ; Ying ZHANG
China Journal of Chinese Materia Medica 2025;50(9):2411-2421
A high-performance liquid chromatography method using pre-column derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate was developed to determine the content of 15 amino acids in the medicinal snakes Bungarus Parvus, Agkistrodon, and Zaocys. The results showed that the total amino acid(TAA) content ranged from 277.13 to 515.05 mg·g~(-1), with the top four amino acids in all three species being glutamic acid(Glu), glycine(Gly), aspartic acid(Asp), and lysine(Lys). The essential amino acid(EAA) content ranged from 74.56 to 203.94 mg·g~(-1), with Agkistrodon exhibiting the highest content. The non-essential amino acid(NEAA), semi-essential amino acid(semi-EAA), and medicinal amino acid(MAA) content ranged from 189.06 to 318.23, 12.89 to 33.53, and 179.83 to 342.33 mg·g~(-1), respectively, with Zaocys having the highest content in these categories. Amino acid nutritional value was evaluated using the amino acid ratio(RAA), amino acid ratio coefficient(RCAA), and amino acid ratio coefficient score(SRCAA), and the results indicated that all three medicinal snakes possessed good nutritional value. The amino acid composition was similar across the species, though significant differences in content were observed. Based on these differences, an orthogonal partial least squares-discriminant analysis(OPLS-DA) model was established, which could clearly distinguish between the three medicinal snake species. The key differences in amino acid content included Gly, tyrosine(Tyr), Glu, and serine(Ser), which may be related to the observed clinical application differences among the species. Further research into the mechanisms of these differential amino acids is expected to provide more insights into the clinical application disparities of these three medicinal snake species.
Amino Acids/chemistry*
;
Animals
;
Nutritive Value
;
Chromatography, High Pressure Liquid
;
Snakes/classification*
;
Bungarus
3.Comparative efficacy of two hemopurification filters for treating intra-abdominal sepsis: A retrospective study.
Ye ZHOU ; Ming-Jun LIU ; Xiao LIN ; Jin-Hua JIANG ; Hui-Chang ZHUO
Chinese Journal of Traumatology 2025;28(5):352-360
PURPOSE:
To compare the efficacy of continuous renal replacement therapy (CRRT) using either oXiris or conventional hemopurification filters in the treatment of intra-abdominal sepsis.
METHODS:
We conducted a retrospective analysis of septic patients with severe intra-abdominal infections admitted to our hospital from October 2019 to August 2023. Patients who meet the criteria for intra-abdominal sepsis based on medical history, symptoms, physical examination, and laboratory/imaging findings were included.
EXCLUSION CRITERIA:
pregnancy, terminal malignancy, prior CRRT before intensive care unit admission, pre-existing liver or renal failure. Heart rate (HR), mean arterial pressure, oxygenation index, lactic acid level (Lac), platelet count (PLT), neutrophil percentage, serum levels of procalcitonin, C-reactive protein, interleukin (IL)-6, norepinephrine dosage, acute physiology and chronic health evaluation II (APACHE II), and sequential organ failure assessment (SOFA) scores before and after 24 h and 72 h of treatment, as well as ventilator use time, hemopurification treatment time, intensive care unit and hospital lengths of stay, and 14-day and 28-day mortality were compared between patients receiving CRRT using either oXiris or conventional hemofiltration. Statistical analysis was performed using SPSS Statistics 26.0 software, including the construction of predictive models via logistic regression equations and repeated measures ANOVA.
RESULTS:
Baseline values including time to antibiotic administration, time to source control, and time to initiation of CRRT were similar between the 2 groups (all p>0.05). Patients receiving conventional CRRT exhibited significant changes in HR but of none of the other indexes at the 24 h and 72 h time points (p=0.041, p=0.026, respectively). The oXiris group showed significant improvements in HR, Lac, IL-6, and APACHE II score 24 h after treatment (p<0.05); after 72 h, all indexes were improved except PLT (all p<0.05). Intergroup comparison disclosed significant differences in HR, Lac, norepinephrine dose, APACHE II, SOFA, neutrophil percentage, and IL-6 after 24 h of treatment (p<0.05). Mean arterial pressure, serum levels of procalcitonin, C-reactive protein, SOFA score, and norepinephrine dosage were similar between the 2 groups at 24 h (p>0.05). Except for HR, oxygenation index, and PLT, post-treatment change rates of △ (%) were significantly greater in the oXiris group (p < 0.05). Duration of ventilator use, CRRT time, and intensive care unit and hospital lengths of stay were similar between the 2 groups (p>0.05). The 14-day mortality rates of the 2 groups were similar (p=0.091). After excluding patients whose CRRT was interrupted, 28-day mortality was significantly lower in the oXiris than in the conventional group (25.0% vs. 54.2%; p=0.050). The 28-day mortality rate increased by 9.6% for each additional hour required for source control and by 21.3% for each 1-point increase in APACHE II score.
CONCLUSIONS
In severe abdominal infections, the oXiris filter may have advantages over conventional CRRT, which may provide an alternative to clinical treatment. Meanwhile, early active infection source control may reduce the case mortality rate of patients with severe abdominal infections.
Humans
;
Retrospective Studies
;
Female
;
Male
;
Middle Aged
;
Sepsis/mortality*
;
Aged
;
Adult
;
Continuous Renal Replacement Therapy/methods*
;
Intraabdominal Infections/mortality*
;
APACHE
;
Organ Dysfunction Scores
;
Intensive Care Units
;
Treatment Outcome
4.A propensity score-matched analysis on biopsy methods: enhanced detection rates of prostate cancer with combined cognitive fusion-targeted biopsy.
Bi-Ran YE ; Hui WANG ; Yong-Qing ZHANG ; Guo-Wen LIN ; Hua XU ; Zhe HONG ; Bo DAI ; Fang-Ning WAN
Asian Journal of Andrology 2025;27(4):488-494
The choice of biopsy method is critical in diagnosing prostate cancer (PCa). This retrospective cohort study compared systematic biopsy (SB) or cognitive fusion-targeted biopsy combined with SB (CB) in detecting PCa and clinically significant prostate cancer (csPCa). Data from 2572 men who underwent either SB or CB in Fudan University Shanghai Cancer Center (Shanghai, China) between January 2019 and December 2023 were analyzed. Propensity score matching (PSM) was used to balance baseline characteristics, and detection rates were compared before and after PSM. Subgroup analyses based on prostate-specific antigen (PSA) levels and Prostate Imaging-Reporting and Data System (PI-RADS) scores were performed. Primary and secondary outcomes were the detection rates of PCa and csPCa, respectively. Of 2572 men, 1778 were included in the PSM analysis. Before PSM, CB had higher detection rates for both PCa (62.9% vs 52.4%, odds ratio [OR]: 1.54, P < 0.001) and csPCa (54.9% vs 43.3%, OR: 1.60, P < 0.001) compared to SB. After PSM, CB remained superior in detecting PCa (63.1% vs 47.9%, OR: 1.86, P < 0.001) and csPCa (55.0% vs 38.2%, OR: 1.98, P < 0.001). In patients with PSA 4-12 ng ml -1 (>4 ng ml -1 and ≤12 ng ml -1 , which is also applicable to the following text), CB detected more PCa (59.8% vs 40.7%, OR: 2.17, P < 0.001) and csPCa (48.1% vs 27.7%, OR: 2.42, P < 0.001). CB also showed superior csPCa detection in those with PI-RADS 3 lesions (32.1% vs 18.0%, OR: 2.15, P = 0.038). Overall, CB significantly improves PCa and csPCa detection, especially in patients with PSA 4-12 ng ml -1 or PI-RADS 3 lesions.
Humans
;
Male
;
Prostatic Neoplasms/diagnosis*
;
Propensity Score
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Image-Guided Biopsy/methods*
;
Prostate-Specific Antigen/blood*
;
Prostate/diagnostic imaging*
5.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Construction of plasma metabolic profile of type 2 diabetic mellitus patients based on UPLC-QTOF/MS non-targeted metabonomics
Man-Li ZHU ; Yan-Dong FAN ; Ye WANG ; Feng-Cai JI ; Xue YANG ; Xue-Hui LI ; Lin-Lin LI
The Chinese Journal of Clinical Pharmacology 2024;40(19):2891-2895
Objective To explore the changes of plasma metabolites in Uygur and Kazak patients with type 2 diabetes mellitus(T2DM)and people with normal glucose tolerance(NGT),construct the profile of different metabolites and analyze different metabolic pathways.Methods Plasma samples of T2DM and NGT from Uygur and Kazak were collected for detection.Ultra-high performance liquid chromatography tandem quadrupole time-of-flight mass spectrometry was used for detection.MetaboAnalyst 5.0 was used to analyze the data,and the screening conditions were P<0.05 and fold change(FC)<0.90 or FC>1.10.We used The Kyoto Encyclopedia of Genes and Genomes database to enrich and explore the metabolic pathways of different metabolites.Results Compared with the Uighur NGT group,there are 109 differential metabolites in the T2DM group,and 43 unique differential metabolites are mainly concentrated in five pathways,such as phenylalanine biosynthesis,tyrosine biosynthesis,and tryptophan metabolism.Compared with the NGT group,Kazak T2DM has 86 differential metabolites,and 28 unique differential metabolites are mainly enriched in the urea cycle,arginine,and proline metabolism(impact>0.10,P<0.05).Conclusion In this study,the plasma metabolic profile of T2DM patients was constructed,and the unique metabolites of T2DM in Uygur and Kazak were screened out,which provided potential biomarkers for early prevention of T2DM.

Result Analysis
Print
Save
E-mail