1.Determination of 4-methyl-2-pentanol in workplace air by solvent desorption-gas chromatography
Guanlin CHEN ; Qiang TAN ; Yaoji FENG ; Hongjun LAN ; Xuewang YANG ; Xueqiong ZHOU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(10):859-862
Objective:To establish a method for the determination of 4-methyl-2-pentanol in the air of workplace by gas chromatography.Methods:In January 2022, 4-methyl-2-pentanol in the air of workplace was collected by activated carbontube, eluted with dichloromethane-methanol (95∶5, V/ V), separated by capillary column and determined by gas chromatogram. Results:The limit of detection for 4-methyl-2-pentanol was 0.04 μg/ml. The linear range of 4-methyl-2-pentanol was 0.16-1616.60 μg/ml, with the regression equation of y=1.94 x-5.48, and the coefficient correlation was 0.99958, and the minimum detection concentration was 0.03 mg/m 3 (collected sample volume was 1.50 L). The within-run precisions were 1.08%-1.75% and the between-run precisions were 1.41%-2.52%. The desorption rates were 95.15%-99.91%. The samples could be stored at least 3 days at room temperature and 7 days at 4 ℃ without significant loss. Conclusion:The method has the advantages of good precision, high sensitivity and simple operation. It is suitable for the determination of 4-methyl-2-pentanol in the air of workplace.
2.Determination of 4-methyl-2-pentanol in workplace air by solvent desorption-gas chromatography
Guanlin CHEN ; Qiang TAN ; Yaoji FENG ; Hongjun LAN ; Xuewang YANG ; Xueqiong ZHOU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(10):859-862
Objective:To establish a method for the determination of 4-methyl-2-pentanol in the air of workplace by gas chromatography.Methods:In January 2022, 4-methyl-2-pentanol in the air of workplace was collected by activated carbontube, eluted with dichloromethane-methanol (95∶5, V/ V), separated by capillary column and determined by gas chromatogram. Results:The limit of detection for 4-methyl-2-pentanol was 0.04 μg/ml. The linear range of 4-methyl-2-pentanol was 0.16-1616.60 μg/ml, with the regression equation of y=1.94 x-5.48, and the coefficient correlation was 0.99958, and the minimum detection concentration was 0.03 mg/m 3 (collected sample volume was 1.50 L). The within-run precisions were 1.08%-1.75% and the between-run precisions were 1.41%-2.52%. The desorption rates were 95.15%-99.91%. The samples could be stored at least 3 days at room temperature and 7 days at 4 ℃ without significant loss. Conclusion:The method has the advantages of good precision, high sensitivity and simple operation. It is suitable for the determination of 4-methyl-2-pentanol in the air of workplace.