1.Clinical research of neutrophil parameters Neut-X and Neut-Y in patients with blood stream infection
Guifang CHEN ; Wenjun DENG ; Yifang ZHAI ; Yanrong ZHENG ; Fengzhi ZHENG
International Journal of Laboratory Medicine 2016;37(23):3283-3284,3287
Objective To investigate the clinical significance of neutrophil parameters Neut‐X and Neut‐Y in the diagnosis of blood stream infection(BSI) .Methods The data in106 patients with blood stream infection and 51 cases in the healthy control group were retrospectively analyzed .The results of WBC ,neutrophil percentage ,Neut‐X ,Neut‐Y and procaclitonin (PCT ) were compared .Results Neut‐X and Neut‐Y in the BSI group were 1 393 .5 ± 33 .4 and 416 .2 ± 30 .0 respectively ,which were signifi‐cantly higher than 1 371 .9 ± 32 .7 and 391 .7 ± 23 .7 in bacterial culture negative group and 1 347 .2 ± 26 .2 and 371 .9 ± 21 .5 in the healthy control group ,the differences were statistically significant (P<0 .05) .Neut‐X and Neut‐Y had good correlation with PCT . Neut‐X and Neut‐Y levels in the Gram‐negative bacterial group were higher than those in the Gram‐positive bacterial group .Conclu‐sion Neut‐X and Neut‐Y parameters in the patients with BSI are significantly increased and can be used as the assistant diagnosis parameters of blood stream infection .
2.Research siblings identification by Identiffler system and automatic STR genetic
Yanxia GUO ; Yanrong KANG ; Wanshui LI ; Song CHEN ; Guochen ZHANG ; Kaihui LIU ; Yandong GUO ; Jiali LI ; Hongling GUO ; Jinping HAO ; Lu LIU ; Jian YE ; Xiaoyu XU ; Yuan OU ; Jian ZHANG ; Xiaojian LIN ; Hua WANG ; Yashen ZHAI ; Ruihua MI
Chinese Journal of Forensic Medicine 2009;24(6):368-371
Objective To evaluate the probability of siblings identification in Identifiler system by using the software of automatic analysis.Methods Using the software of automatic analysis in siblings jdentification.STP genetic typing of 151 pairs of full siblings and 31224 pairs of unrelated individuals from manual simulation were analyzed in 15 STR loci of ldentifiler system.Results Kin probability(W_(FS))of 39.07% full siblings were more than 99.999% while W_(FS) of unrelated individual pairs were 0% .W_(FS) of 60.93% full siblings and 21.3% unrelated individual pairs were all at the range from 99.999% to 1% .W_(FS) of 78.7% unrelated individual pairs 0% full siblings individuals were less than 1% .Therefore,there were notability difference between full siblings and unrelated individual pairs.In addition,testing of 15 STR loci of Identifiler system,it suggested that the pair were siblings when the locus number of the entirely-same is not less than 5 or that of the entirely-different is not more than 1,and that the pair were unrelated individuals when the locus number of the entirely-different is not less than 6 or that of the entirely-8alne is not more than 1.Conclusion The software of automatic analysis and the Identifiler system call be used to siblings identification.
3.Preliminary clinical efficacy of percutaneous plate internal fixation with fracture reduction oriented forcep for lower humeral fractures
Yanrong ZHAI ; Ping WANG ; Chunhua SUN ; Fei SHEN ; Jiarong LI ; Kejia YANG ; Jihe HUANG ; Yinxi WANG ; Yaozeng XU
Chinese Journal of Trauma 2019;35(3):259-266
Objective To investigate the preliminary clinical efficacy of percutaneous plate internal fixation with fracture reduction oriented forcep in the treatment of lower humeral fractures. Methods A retrospective case control study was conducted to analyze the clinical data of 46 patients with lower humeral fractures admitted to Wuzhong People's Hospital of Suzhou from October 2013 to March 2015. There were 25 males and 21 females, aged 19-76 years, with an average age of 45. 7 years. A total of 22 patients ( percutaneous group) were treated with minimally invasive percutaneous internal fixation with self-developed fracture reduction oriented forcep according to the dimensionality reduction method (DRM). The other 24 patients (control group) were treated with open reduction internal fixation. The length of incision, operation time, intraoperative blood loss, fracture healing time, the American Foot and Ankle Surgery Association ( AOFAS ) ankle-hindfoot score at the last follow-up, and postoperative complications were compared between the two groups. Results All patients were followed up for 12-24 months, with an average of 14. 6 months. There were statistically significant differences between percutaneous group and control group in incision length [(7.1 ±0.8)cm vs. (8.8 ±0.7)cm, operation time [(32.5 ±4.9)min vs. (39.2 ±4.3)min], intraoperative blood loss [(8.0 ±2.7) ml vs. (31.0 ± 11.4)ml], and fracture healing time (16.4 ±2.3)weeks vs. (19.5 ±2.9)weeks], respectively (all P<0.05). In percutaneous group, the AOFAS ankle-hindfoot score was (92.3 ±5.9)points (range, 75-99 points ) , and the overall results were good and excellent in 21/22 ( 96%) including excellent results in 18 patients, good in three, fair in one and poor in 0. In control group, the AOFAS ankle-hindfoot score was (91.8 ±4.9)points (range, 76-99 points), and the overall results were good and excellent in 23/24 (96%) including excellent results in 20 patients, good in three, fair in one and poor in 0. There was no significant difference in the excellent and good rate between two groups (P>0. 05). Poor wound healing was observed in one patient in control group. No case of nonunion was found in either group. Conclusion For lower humeral fractures, the percutaneous plate internal fixation with fracture reduction oriented forcep has the characteristics of simple operation, shortened operation time, reduced soft tissue injury and blood loss, and quick healing of the fracture, which is worthy of clinical application.
4.Sox9 Is Crucial for Mesenchymal Stem Cells to Enhance Cutaneous Wound Healing
Qingli BIE ; Ruixia ZHAI ; Yanrong CHEN ; Yingao LI ; Na XIE ; Baoyi WANG ; Poyun YUAN ; Xinjie ZHOU ; Haiyan CONG ; Xin CHANG ; Huabao XIONG ; Bin ZHANG
International Journal of Stem Cells 2021;14(4):465-474
Background and Objectives:
Human umbilical cord mesenchymal stem cells (HUC-MSCs) are promising candidates for cell-based therapy in regenerative medicine or other diseases due to their superior characteristics, including higher proliferation, faster self-renewal ability, lower immunogenicity, a noninvasive harvest procedure, easy expansion in vitro, and ethical access, compared with stem cells from other sources.
Methods:
and Results: In the present study, we knocked down the expression of SOX9 in HUC-MSCs by lentivirus interference and found that knockdown of SOX9 inhibited the proliferation and migration of HUC-MSCs and influenced the expression of cytokines (IL-6 and IL-8), growth factors (GM-CSF and VEGF) and stemness-related genes (OCT4 and SALL4). In addition, the repair effect of skin with burn injury in rats treated with HUC-MSCs transfected with sh-control was better than that rats treated with HUC-MSCs transfected with shSOX9 or PBS, and the accessory structures of the skin, including hair follicles and glands, were greater than those in the other groups. We found that knockdown of the expression of SOX9 obviously inhibited the expression of Ki67, CK14 and CK18.
Conclusions
In conclusion, this study will provide a guide for modifying HUC-MSCs by bioengineering technology in the future.
5.Effectiveness and safety of the home-made umbrella-shaped Octoparms inferior vena cava filter in the prevention of pulmonary embolism
Boxiang ZHAO ; Jianlong LIU ; Gaojun TENG ; Caifang NI ; Hao XU ; Zhen LI ; Shuiting ZHAI ; Yanrong ZHANG ; Hua XIANG ; Weizhu YANG ; Jianping GU
Chinese Journal of Radiology 2022;56(5):556-562
Objective:To evaluate the effectiveness and safety of the home-made umbrella-shaped Octoparms inferior vena cava filter in the prevention of pulmonary embolism.Methods:A multicenter, randomized, positive parallel controlled, non-inferiority clinical trial was conducted in ten hospitals in China from October 2017 to March 2019. A total of 188 subjects were enrolled according to the same inclusion and exclusion criteria in different institutes. The 188 subjects were randomly divided into the trial group or the control group according to 1∶1 by the central randomization system, with 94 cases in each group. Octoparms inferior vena cava filter was used in the trial group, and the Celect inferior vena cava filter in the control group. The primary effective index was clinical success rate,including the clinical success rate of filter placement and filter retrieval. The secondary index included the rate of manual success of the delivery sheath system,incidence of pulmonary embolism(within 6 months), incidence of filter fracture,migration (>20 mm),tilt(>15°) on insertion/retrieval,and the situation of inferior vena cava flow(within 6 months). Safety evaluation included the incidence of filter related complications and device-related adverse events immediately after surgery and during follow-up.Results:The success rate of implantation was 100% in 188 subjects. Filter retrieval was performed in 87 cases (92.55%) in the trial group and 91 cases (96.81%) in the control group. The clinical success rate of the trial group was 97.87%(92/94) and that of the control group 98.94%(93/94). There was no significant difference between the two groups (χ 2=0.77, P=0.380). The success rate of delivery sheath system was 96.81%(91/94) and 98.94%(93/94) in the trail group and the control group,respectively. There was no significant difference between the two groups( P=0.621). There was 1 case (1.22%) of new asymptomatic pulmonary embolism in the trial group after filter placement and 2 cases (2.44%) in the control group. There was no significant difference between the two groups ( P>0.05). No filter fracture or migration (>20 mm) occurred in either group. The tilting of filter (>15°) was found in 1 case (1.06%) in the test group and 1 case (1.06%) in the control group when the filter was placed. The tilting of filter (>15°) was found in 0 case in the test group and 2 cases (2.44%) in the control group when the filter was retrieved. There was no significant difference between the two groups ( P>0.05). Inferior vena cava thrombosis before filter retrieval was found in 5 cases (5.75%) in trial group and 3 cases (3.30%) in control group. There was no significant difference between the two groups ( P=0.489). There were no immediate serious complications during filter placement/removal in either group. No filter obstruction,migration,deformation,penetration and occlusion of inferior vena cava. The incidence of device-related adverse events was low in both group. There was no significant difference between the two groups ( P>0.05). Conclusion:The home-made umbrella-shaped Octoparms inferior vena cava filter is effective and safe in preventing pulmonary embolism, and is not worse than Celect filter.