1.Comparison of ocular variables obtained from Tomey OA-2000 and IOLMaster
Yanjun HUA ; Qiuyi XIAO ; Qiang WU
Recent Advances in Ophthalmology 2017;37(9):845-848
Objective To compare the ocular parameters measured by 2 biometry devices Tomey OA-2000 and IOLMaster in cataract eyes.Methods A total of 74 cataract patients (74 eyes) were included in this prospective study.Ocular parameters,including axial length (AL),keratometry (K),anterior chamber depth (ACD) and white to white (WTW),were obtained from Tomey OA-2000 and IOLMaster,respectively.Paired t-test was applied to analyze the differences of ocular parameters from Tomey OA-2000 and IOLMaster,while Bland-Altman plot was used to assess the agreement of these ocular parameters.Results The AL,flat K,steep K,mean K,central corneal thickness (CCT),ACD,lens thickness,pupil diameter and WTW values measured by Tomey OA-2000 were (24.26 ± 2.71) mm,(44.09 ± 1.76) D,(45.01 ± 1.73) D,(44.55 ± 1.72)D,(518.41 ±34.18) μm,(3.07 ±0.48)mm,(4.48 ±0.61)mm,(4.07 ±0.95)mm and (11.50 ± 0.52)mm respectively.Values of AL,flat K,steep K,mean K,ACD and WTW from IOLMaster were (24.33 ± 2.69) mm,(44.21 ± 1.74) mm,(45.15 ± 1.76) D,(44.69 ± 1.74) D,(3.04 ± 0.46)mm and (11.65 ± 0.41) mm respectively.The difference values of AL,flat K,steep K,mean K,ACD and WTW between Tomey OA-2000 and IOLMaster were (-0.07 ±0.10) mm (t =-5.99,P<0.01),(-0.12 ± 0.21) D (t =-4.14,P<0.01),(-0.14 ± 0.20)D (t =-5.88,P<0.01),(-0.12 ±0.13) D (t =-7.44,P<0.01),(0.03 ±0.14) mm (t=1.99,P=0.05) and (-0.14±0.32) mm (t=-3.73,P<0.01) respectively.The 95% limits of agreement (LoA) of the AL,flat K,steep K,mean K,ACD obtained from the two devices was 0.27 mm,0.50 D,0.53 D,0.38 D,0.30 mm,respectively,and the agreement was good;95% LoA of WTW was 0.78 mm,and the consistency was poor.Conclusion The differences of AL,K values and ACD between Tomey OA-2000 and IOLMaster were small,suggesting the agreement is unified.
2.Analysis of prognosis and therapy strategy in patients with lung cancer aged 80 years and over
Hua ZHENG ; Yanjun YIN ; Qunhui WANG ; Heling SHI ; Baolan LI
Chinese Journal of Geriatrics 2012;31(9):767-770
Objective To analyze the prognostic factors and trerapy strategy of lung cancer in the patients aged 80 years and over.Methods Totally 107 patients aged ≥ 80 years with lung cancer were retrospectively reviewed.Patients' clinical characteristics and treatment were analyzed.Results Median survival time of the patients was 6.9 months.92.9% (13/14) of small cell lung cancer patients and 34.4% (31/90) of non small cell lung cancer patients were treated.Life cycle of patients who accepted effective treatments and supportive treatments were 16.5 months and 8.7 months,respectively (P=0.008).In the early stage of tumors,survival time of patients undergoing surgery was 36.7 months,15.5 months in patients without surgery (P=0.023),while in the late stage,survival time of patients receiving combined chemotherapy was 13.4 months,4.6 months in patients receiving single agent chemotherapy(P=0.002).In small cell lung cancer,survival time of patients who received radiotherapy was 12.8 months,6.4 months in patients who did not receive radiotherapy (P=0.049).Performance status (PS),clinical stage,early surgery,late chemotherapy and radiotherapy(x2=38.236,18.831,5.187,9.827,4.186,P<0.05),but not sex and pathology type affected the prognosis.PS score (P=0.003)and clinical stage(P=0.046) were the independent influencing factors.Conclusions Performance status and clinical stage are the independent influencing factors of lung cancer in the patients aged over 80 years.Patients may improve survival if receiving surgery,chemotherapy and/or radiotherapy when they have good PS,otherwise patients may choose best supportive care.
4.EFFECTS OF GANODERMA LUCIDUM POLYSACCHARIDES ON ANTIOXIDANT ABILITY AND MODALITY IN THE HIPPOCAMPUS OF AD RATS
Yanjun GUO ; Hua YUAN ; Lina ZHANG ; Shengwei GAN
Acta Anatomica Sinica 2002;0(05):-
Objective To observe the effects and mechanism of Ganoderma Lucidum Polysaccharides (GLP) on the activity of superoxide dismutase(SOD), the content of malondialdehyde(MDA) of hippocampus tissue and the learning and memory ability. Methods AD rats induced by A? 25-35 were treated with GLP for 7 days and then observing the Morris water maze to study the learning and memory ability, the content of MDA, and the activity of SOD was measured in the hippocampus tissue with spectrophotometer. Ultrastructural changes of neuron were viewed under transmission electron microscope. Results GLP can distinctly improve the learning and memory ability of A?-injected rats(P
5.Repeatability of corneal power measurements by Galilei Ⅱ dual Scheimpflug analyzer in post-LASIK eyes
Yanjun, HUA ; Qinmei, WANG ; Jinhai, HUANG ; Chao, PAN
Chinese Journal of Experimental Ophthalmology 2016;34(4):357-362
Background The assessment of total corneal power is essential to both the prediction of intraocular lens power before cataract surgery and the diagnosis of corneal ectasia.Objective This study was to access the repeatability of corneal power measurements in post-laser assisted in-situ keratomileusis (LASIK) eyes with GalileiⅡ dual Scheimpflug analyzer.Methods In this cross-sectional study,68 eyes of 36 subjects who received LASIK surgery more than 3 months in Eye Hospital of Wenzhou Medical University were recruited from July to September in 2011.The mean preoperative spherical equivalent diopter was (-4.95±2.08) D in the subjects with the diopter range from-1.75 D to-10.00 D.The parameters of corneal power were measured by Galilei Ⅱ dual Scheimpflug analyzer,including SimK,Ka,Kp,KG and Kray.Three-time consecutive measurements were completed in every examined eye to obtain the data of SimK,Ka,Kp,KG and Kray,respectively.The coefficient of variation (CV),standard deviation (SD),Cronbach α coefficient and intra-class correlation coefficient (ICC) were calculated to evaluate the repeatability.Concordance between the different measurements was assessed using Bland-Altman agreement analysis.This study followed the Helsinki Declaration,all subjects signed informed consent.Results The CVs of three-time measured SimK,Ka,Kp,KG and Kray were 0.24%,0.28%,-0.37%,0.31% and 0.32%,respectively,and the Cronbach α values were >0.9 and the ICCs were >0.982.The Bland-Altman analysis between different measurements showed that the maximum 95% limits of agreement (LoA) were 0.37 D for SimK,0.46 D for Ka,0.09 D for Kp,0.45 D for KG and 0.49 D for Kray,respectively.Conclusions The Galilei Ⅱ dual Scheimpflug analyzer performed high repeatability and concordance on corneal power measurements in post-LASIK eyes.The differences between measuring results are clinically acceptable.
6.Comparison of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer
Wei, QIU ; Yanjun, HUA ; Zequan, XU ; Qiang, WU
Chinese Journal of Experimental Ophthalmology 2017;35(6):544-547
Background The measurement of corneal Q value is essential for corneal refractive surgery and calculation of intraocular lens during cataract surgery.Topolyzer was often used for the measurement of Q value,and recently Topcon KR-1W and iTrace were applied in ophthalmology.However,whether the measured values are interchangeable is unclear.Objective This study was to assess the difference and consistency of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer.Methods Corneal Q values were measured on 100 right eyes of 100 healthy subjects under the approval of Ethic Committee of the Sixth Hospital Affiliated to Shanghai Jiaotong University and informed consent of each subject from November to December in 2014 with Topcon KR-1W,iTrace and Topolyzer.Three valid measurements were obtained for each device,and the average values from each device were calculated.The difference of the outcomes among the instruments was compared by repeated measures analysis of variance (ANOVA),and the consistency among the outcomes from different apparatus was analyzed by Bland-Altman plots.Results The mean corneal Q values were-0.184-±0.112,-0.117±0.167 and-0.269±0.117 from Topcon KR-1W,iTrace and Topolyzer,respectively,with a significant difference among them (P < 0.001).The measured Q value by Topcon KR-1W was 0.085±0.010 larger than that by Topolyzer,and the Q values by iTrace was 0.152± 0.014 larger than that by Topolyzer,while the Q values obtained by Topcon KR-1W was 0.067±0.016 smaller than that by iTrace (all at P<0.05).The 95% confidence interval of the values between Topcon KR-1W and iTrace,Topcon KR-1W and Topolyzer,iTrace and Topolyzer were-0.106 to-0.028,0.060 to 0.109 and 0.118 to 0.186,respectively.Bland-Altman plots showed that 6%,6% and 5% values were outside of 95% agreement of limit (LoA) between Topcon KR-1W and iTrace,iTrace and Topolyzer or KR-1W and Topolyzer,respectively,with the maximal differences of 0.28,0.43 and 0.38.Conclusions Corneal Q values measured by Topcon KR-1W and iTrace are larger than those measured by Topolyzer.Due to the poor agreements among the corneal Q values by the 3 kinds of devices,they are not interchangeable in clinical applications for the measurement of corneal Q value.
7.Repair of segmental bone defects with intramedullary nailing and bone cement
Jin TIAN ; Qingrong LIN ; Lei WANG ; Yanjun HU ; Hua WANG
Chinese Journal of Orthopaedic Trauma 2021;23(4):359-363
Objective:To investigate the clinical efficacy of intramedullary nailing combined with bone cement in repair of segmental bone defects after tumor resection.Methods:A retrospective analysis was conducted of the 5 patients with malignant bone tumor who had been treated at Department of Orthopaedics, Qiannan People's Hospital from April 2018 to September 2019 for remaining segmental bone defects following limb salvage surgery. They were 4 males and one female, aged from 11 to 55 years (average, 35.4 years). Their defects ranged from 6 to 21 cm (average, 12.3 cm) after tumor resection. By the Karnofsky performance score (KPS) for long-term quality of life, all of them scored less than 50 points. Of them, 3 were treated by interlocking intramedullary nails and bone cement filling, and 2 by elastic intramedullary nails and bone cement filling. In the 2 cases with defects of 21 cm and 13 cm, the fixation was assisted by a plate and an external fixator. Defect length after resection, operation time and intraoperative bleeding were recorded; the efficacy was evaluated by the Enneking functional evaluation of reconstructive procedures after surgical treatment of tumors of the musculoskeletal system, visual analogue scale (VAS), and KPS.Results:All the 5 patients had uneventful surgery, with operation time ranging from 112 to 225 min (average, 154.2 min), intraoperative bleeding from 300 to 500 mL (average, 382 mL), and defect length after resection from 6 to 21 cm. The 5 patients were followed up for 6 to 28 months. Of them, 2 died of disease progression 6 and 7 months after surgery, respectively. According to the Enneking's evaluation, one patient scored 28 points, 2 patients 23 points and 2 patients 21 points, giving a high degree of satisfaction. Their VAS scores 6 months after surgery ranged from 1 to 6, averaging 3.6; their postoperative KPS scores ranged from 60 to 80, averaging 72.Conclusion:In repair of segmental bone defects after tumor resection, intramedullary nailing combined with bone cement filling can relieve pain of patients and lead to satisfactory short-term curative efficacy.
8.The Relationship between the Development of Auditory and Speech in Children with Hearing Loss after Hearing Aid Fitting
Jing LYU ; Xueqing CHEN ; Hua ZHANG ; Jing LI ; Yanjun WU ; Shuo WANG ; Ying KONG
Journal of Audiology and Speech Pathology 2017;25(5):511-516
Objective To study the relationship between the development of auditory and speech in children with hearing loss after hearing aid fitting and discuss the development of speech with the ability of auditory in children at different stages of evaluation, with different degrees of hearing loss and different ages respectively.Methods A total of 19 children (14 boys and 5 girls) with hearing loss participated in this study.The age at hearing aid fitting ranged from 3 to 8 years old with a mean of 5.42±1.86 years old.According to their hearing levels, the children in this study were divided into two groups: the moderate hearing loss group (n=10) and the severe group (n=9).According to their ages at hearing aid fitting, all children in this study were divided into two groups: the less than or equal to six years old (n=11) and greater than six years old (n=8).MAIS and MUSS were used to evaluate their abilities of auditory and speech at pre-fitting, 1, 3, 6, 9 and 12 months after hearing aids were worn respectively.A linear and regression analysis was done in the statistic procedure.Results There was a significant correlation between the scores of MAIS and MUSS (R=0.774,P<0.05).There was also a significant correlation between the scores of MAIS and MUSS for the different evaluating stages respectively.The correlations were pre-fitting (R=0.710,P<0.05), 1 month after hearing aid fitting (R=0.774,P<0.05), 3 months after hearing aid fitting (R=0.814,P<0.05), 6 months after hearing aid fitting (R=0.819,P<0.05), 9 months after hearing aid fitting (R=0.707,P<0.05), 12 months after hearing aid fitting (R=0.649,P<0.05).There was also a significant correlation between the scores of MAIS and MUSS for MAIS (items 3~6) (Sound awareness) and MAIS (items 7~10) (Sound understanding).The correlations for MAIS (items 3~6) were (R=0.768,P<0.05), and for MAIS (items 7~10) (Sound understanding) (R=0.794,P<0.05).There was also a significant correlation between the scores of MAIS and MUSS for different group of ages.The correlations for the group of <6years old were (R=0.808,P<0.05), and for the group of the ≥6 years old (R=0.775,P<0.05).There was also a significant correlation between the scores of MAIS and MUSS for different groups of hearing loss levels.The correlation for the group of moderate hearing loss was (R=0.771,P<0.05), and the group of severe hearing loss (R=0.787,P<0.05).Conclusion The development of auditory ability is closely related to the speech ability.The speech abilities increase with the improvement of auditory abilities.The less severe the hearing loss is, the longer the use of hearing aids, the younger the children are, the better the speech ability improved with auditory ability development after hearing aid fitting.
9.The Relationship between the Development of Auditory and Speech in Infants with Hearing Loss after Hearing Aid Fitting
Jing LYU ; Xueqing CHEN ; Hua ZHANG ; Jing LI ; Yanjun WU ; Shuo WANG ; Ying KONG
Journal of Audiology and Speech Pathology 2015;(5):518-521
Objective The aim of this study is to analyze the relationship between the development of audito‐ry and speech in infants with hearing loss after hearing aid fitting and discuss the development of speech with the a‐bility of auditory in infants with different degree of hearing loss and different stage of evaluation after hearing aid fit‐ting .Methods A total of 32 infants (17 boys and 15 girls) with prelingual hearing loss participated in this study . The age at hearing aid fitting ranged from 3 to 34 months with a mean of 15 .6 months .According to their hearing level ,all infants in this study were divided into three groups :group of profound hearing loss(16) ,group of severe hearing loss(11) ,group of moderate hearing loss(5) .CAP and SIR were used to evaluate their abilities of auditory and speech at pre -fitting ,1 ,3 ,6 ,9 and 12 months after hearing aid fitting respectively .A linear and regression a‐nalysis was done in the statistic procedure .Results There was a significant correlation between the scores of CAP and SIR for the three groups respectively .The correlation from low to high followed by the group of profound hear‐ing loss (R=0 .656 ,P=0 .000<0 .05) ,group of severe hearing loss (R=0 .758 ,P=0 .000<0 .05) ,group of mod‐erate hearing loss (R=0 .849 ,P=0 .000<0 .05) .There was also a significant correlation between the scores of CAP and SIR for the different evaluating stages respectively .The correlation from low to high followed by pre -fitting (R=0 .559 ,P=0 .000<0 .05) ,1 month after hearing aid fitting (R=0 .575 ,P=0 .000<0 .05) ,3 months after hearing aid fitting (R=0 .726 ,P=0 .000<0 .05) ,6 months after hearing aid fitting (R=0 .823 ,P=0 .000<0 .05) , 9 months after hearing aid fitting (R=0 .838 ,P=0 .000<0 .05) ,12 months after hearing aid fitting (R=0 .855 ,P=0 .000<0 .05) .Conclusion The development of auditory ability is closely related to speech ability which increases with the improvement of auditory ability .The less the infants have the hearing loss and the longer the infants use the hearing aids ,the higher the auditory ability is related to speech ability in infants after hearing aid fitting .
10.Diagnostic value of SPECT/CT for lumbar spondylolysis
Qian HUA ; Baoming MI ; Bin ZHANG ; Ping TANG ; Yanjun ZHAO ; Jianming NI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2015;35(4):280-283
Objective To evaluate the diagnostic value of 99Tcm-MDP SPECT/CT in the diagnosis of lumbar spondylolysis.Methods A total of 58 patients (28 males,30 females,average age 61.3 years) who underwent bone scan and SPECT/CT because of low back pain from January 2012 to May 2014 were retrospectively evaluated.The final diagnosis was based on comprehensive results of SPECT/CT and followup.The diagnostic sensitivity and accuracy of SPECT,CT and SPECT/CT images were calculated and x2 test was performed to analyze the data.Results Twenty-eight patients were diagnosed as lumbar spondylolysis.The diagnostic sensitivities of SPECT,CT and SPECT/CT were 53.6% (15/28),78.6% (22/28) and 100%(28/28).The diagnostic accuracies of SPECT,CT and SPECT/CT were 48.3% (28/58),89.7% (52/58) and 93.1%(54/58).SPECT/CT was proved to be more accurate than SPECT(x2=28.13,P< 0.05).Conclusion SPECT/CT bone scan may detect lumbar spondylolysis in early stage.