1.Simulation and Design of Infant Incubator Assembly Line.
Huqi KE ; Xiaoyong HU ; Xia GE ; Yanhai HU ; Zaihong CHEN
Chinese Journal of Medical Instrumentation 2015;39(6):421-431
According to current assembly situation of infant incubator in company A, basic industrial engineering means such as time study was used to analyze the actual products assembly production and an assembly line was designed. The assembly line was modeled and simulated with software Flexsim. The problem of the assembly line was found by comparing simulation result and actual data, then through optimization to obtain high efficiency assembly line.
Equipment Design
;
Humans
;
Incubators, Infant
;
Infant
;
Software
2.Establishment of real-time fluorescent quantitative PCR for detection of torque teno virus types 7, 8 and 10
Zhiqiang XIA ; Juan SONG ; Dong XIA ; Qinqin SONG ; Wenjun WANG ; Ruifang WANG ; Bingtian SHI ; Mi LIU ; Geng HU ; Yanhai WANG ; Jun HAN
Chinese Journal of Microbiology and Immunology 2021;41(3):190-194
Objective:To establish a real-time fluorescent quantitative PCR for the detection of torque teno virus types 7 (TTV7), 8 (TTV8) and 10 (TTV10) and analyze its performance in clinical sample detection.Methods:Specific primers were designed based on the gene sequences of TTV7, TTV8 and TTV10 in GenBank. Recombinant plasmids of pMD19-T-TTV7, pMD19-T-TTV8 and pMD19-T-TTV10 were constructed and used as positive standard control to establish a real-time fluorescent quantitative PCR based on FAM-Eclipse probe method. The specificity and sensitivity of the established method were evaluated. Moreover, it was validated in terms of clinical sample detection.Results:The standard curve equations of the real-time fluorescent quantitative PCR for detecting TTV7, TTV8 and TTV10 were y=-0.340 2 x+ 114.780 0 ( R2=0.998 8), y=-0.351 1 x+ 114.940 0 ( R2=0.995 3) and y=-0.348 9 x+ 115.020 0 ( R2=0.991 7), respectively, and there was no cross-reaction with other viruses. The detection sensitivity of the established method for TTV7, TTV8 and TTV10 were 108 copies/μl, 84 copies/μl and 98 copies/μl, and the positive detection rates in clinical pediatric serum samples were 10.9%, 2.1% and 4.3%, respectively. Conclusions:The established real-time fluorescent quantitative PCR for detection of TTV7, TTV8 and TTV10 was featured by strong specificity and high sensitivity, which could be used for rapid TTV detection in clinical serum samples.
3.Risk factors and predictive value of estimated glomerular filtration rate for new-onset atrial fibrillation in patients with hypertrophic obstructive cardiomyopathy after modified extended Morrow procedure
Yanhai MENG ; Ping LIU ; Yanbo ZHANG ; Shengwei WANG ; Changsheng ZHU ; Shuo CHANG ; Qi QI ; Enci HU ; Liang LI ; Zina LIU ; Shuiyun WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2021;28(10):1234-1241
Objective To explore the association between preoperative, perioperative parameters, especially estimated glomerular filtration rate (eGFR) and postoperative atrial fibrillation (POAF) after modified extended Morrow procedure. Methods A total of 300 hypertrophic obstructive cardiomyopathy (HOCM) patients who underwent modified extended Morrow procedure in our hospital from January 2012 to March 2018 were collected. There were 197 (65.67%) males and 103 (34.33%) females with an average age of 43.54±13.81 years. Heart rhythm was continuously monitored during hospitalization. The patients were divided into a POAF group (n=68) and a non-POAF group (n=232). The general data, perioperative parameters and echocardiographic results were collected by consulting medical records for statistical analysis. Univariate and multivariate logistic regression models were used to analyze the risk factors for POAF. Results Overall incidence of POAF during hospitalization was 22.67% (68/300). Compared with patients without POAF, patients with POAF were older, had higher incidence of chest pain and syncope, lower level of preoperative eGFR, higher body mass index and heart function classification (NYHA), larger preoperative left atrial diameter and left ventricular end diastolic diameter, and longer ventilator-assisted time, ICU stay and postoperative hospital stay. Age, heart function classification (NYHA)≥Ⅲ, hypertension, syncope history and eGFR were independent risk factors for POAF. Receiver operating characteristic curve analysis showed that the area under the curve of eGFR was 0.731 (95%CI 0.677-0.780, P<0.001), and the sensitivity and specificity were 82.4% and 57.8%, respectively. Conclusion Increased age, high preoperative heart function classification (NYHA), hypertension, preoperative syncope history and decreased eGFR are independent risk factors for POAF in HOCM patients who underwent surgical septal myectomy. Preoperative decreased eGFR can moderately predict the occurrence of POAF after modified extended Morrow procedure.