1.Analysis of Hepatic Encephalopathy After TIPSS
Wenhong CHEN ; Yuxin NONG ; Yangsheng LIU
Journal of Chinese Physician 2001;0(01):-
Objective To investigate the causes and characterization of hepatic encephalopathy after transjugular intrahepatic portosystemic shunts(TIPSS).Methods 32 cases of patients with recepted TIPSS operation were enrolled in retrospective study.Results 9 of 32 patients suffered from hepatic encephalopathy were detected out after TIPSS. The present of hepatic encephalopathy was associated with the flow direction of blood in portvein after the operation(P
2.Preparation and in vitro Dissolution Behavior Investigation of Frovatriptan Succinate Film-coated Tablet
Xiaoxia LIU ; Minggang WANG ; Yangsheng CHEN ; Guiyu SUN ; Yunlong ZANG
China Pharmacy 2017;28(19):2696-2699
OBJECTIVE:To prepare Frovatriptan succinate film-coated tablet,and investigate its in vitro dissolution behavior. METHODS:Using lactose monohydrate,microcrystalline cellulose,dioxide,silica,sodium carboxymethyl starch and magnesium stearate as accessories,Frovatriptan succinate tablet was prepared. Using opadry premix spray-coating liquid,Frovatriptan succinate film-coated tablet was prepared. Single factor test was used,using moisture,angle of repose,rigidity,friability,disintegration time and dissolution rate as indexes,to screen the formulation;using dissolution degree as index,coating material dosage was screened. The dissolution curves in vitro of self-made tablets and imported tablets in water,0.1 mol/L HCL,pH of 5.5,6.8 phos-phate buffer solutions were compared. RESULTS:The optimal formulation of Frovatriptan succinate uncoated tablet was as follow as frovatriptan succinate 3.91 mg,lactose monohydrate 99.18 mg,microcrystalline cellulose 33.06 mg,magnesium stearate 1.40 mg,sodium carboxymethyl starch 1.05 mg,silica 1.40 mg;optimal coating weighed quality was 2.0%-4.0%. In the 4 mediums, the dissolution behavior of self-made tablets and imported tablets were similar. CONCLUSIONS:Frovatriptan succinate film-coated tablet is prepared successfully,and its in vitro dissolution behavior is similar to the imported preparations.
3.Semantic extension to DICOM standard.
Kai ZHANG ; Lei CHEN ; Chen ZHAO ; Yangsheng LÜ
Journal of Biomedical Engineering 2006;23(2):287-289
The Digital Imaging and Communications in Medicine (DICOM) Standard was developed by National Electrical Manufacturers Association (NEMA) and the American College of Radiology (ACR) for medical image archiving and communication. The Standard is widely used in medicine now. But it does not define image semantic content sufficiently, so there is a difficulty in the implementation based on semantic content. In this article are discussed the semantic hierarchy structure in medical image and the method to describe the image content used in the DICOM Standard. We point out the limitations of DICOM in image semantic content description, and then set forth a way to extend the semantic content description by using DICOM private attributes.
Computer Communication Networks
;
standards
;
Humans
;
Image Processing, Computer-Assisted
;
standards
;
Programming Languages
;
Radiology Information Systems
;
standards
;
Semantics
4.Finite element analysis of effects of sagittal cervical manipulation on intervertebral disc and facet joints
Yuanbiao WEI ; Zhan LIN ; Yanmei CHEN ; Tenghui YANG ; Xiao ZHAO ; Yangsheng CHEN ; Yanhui ZHOU ; Minchao YANG ; Feiqi HUANG
Chinese Journal of Tissue Engineering Research 2024;28(6):827-832
BACKGROUND:Among the pathogenic factors of cervical spondylosis,herniation of the intervertebral disc,dislocation of the facet joint and the stenosis of the intervertebral foramen are important factors leading to symptoms in patients.Moreover,inappropriate manipulation may aggravate the possibility of cervical disc rupture,leading to exacerbation of symptoms in patients. OBJECTIVE:To compare the effect between sagittal cervical manipulation and traditional cervical rotation manipulation on the area of the intervertebral disc,facet joint and intervertebral foramen at the operative segment by the finite element analysis. METHODS:The neck CT data of a male volunteer with a normal neck were selected and imported into Mimics 17.0 three-dimensional reconstruction software.Geo-magic Studio 12.0,Solidworks 2017 and Ansys Workbench 17.0 software were used for the construction of the finite element model of cervical vertebrae(C3-6)including intervertebral disc and articular cartilage.The lower end plate of the C5 vertebral body was fixed.A uniformly distributed vertical downward 50 N load was applied on the upper surface of the upper vertebral body(C3).The stress,deformation and deformation direction of the C4-5 intervertebral disc,joint capsule stress,the displacement of facet joints and the area of bilateral intervertebral foramen were compared between sagittal cervical manipulation and traditional rotation reduction. RESULTS AND CONCLUSION:(1)When using the rotation technique,the maximum normal equivalent stress(von Mises stress)of the C4-5 disc was 8.06 MPa;the total deformation was 1.05 mm,and the fiber ring expanded to the left and outside.When using the sagittal tip lifting technique,the maximum normal equivalent stress(von Mises stress)of the C4-5 disc was 2.60 MPa;the total deformation was 0.90 mm,and the fiber ring expanded to the left and back.Compared with the rotation technique,the pressure of the cervical manipulation technique on the disc was less(about 32.3%of the rotation technique),and the deformation degree of the disc was also light(about 85.7%of the rotation technique).(2)When the rotation technique was used,the maximum stresses of the left and right articular capsule ligaments were 0.37 MPa and 1.69 MPa,respectively.The overall displacement of the facet joint was 2.21 mm.The area of the right intervertebral foramen decreased by about 3.8%and the area of the left intervertebral foramen increased by about 0.9%.When the sagittal end lifting manipulation was performed,the maximum stresses of the left and right articular capsule ligaments were 0.27 MPa and 1.70 MPa,respectively;the overall displacement of the facet joint was 1.63 mm;the area of the right intervertebral foramen increased by about 2.6%,and the area of the left intervertebral foramen decreased by about 0.9%.Compared with rotation manipulation,sagittal end lifting manipulation had fewer changes in the displacement of facet joint,joint capsule stress and intervertebral foramen area,so it was safer to operate.(3)In conclusion,compared with cervical rotation manipulation,sagittal end lifting manipulation has fewer changes in facet joint displacement,intervertebral disc stress/deformation degree,joint capsule stress,and foraminal area.In clinical practice,more appropriate manipulation should be selected based on biomechanical results after an accurate assessment of patients'conditions.
5.Empirical Analysis on Influential Factors of Cross-regional Innovation Cooperation in Pharmaceutical Manufactu- ring Based on Patent Cooperation Data
Yongjie CHEN ; Yangsheng ZHAO ; Huiyuan HUANG ; Shuzhen CHU
China Pharmacy 2020;31(6):641-646
OBJECTIVE:To provide referen ce for promoting innovation cooperation of pharmaceutical manufacturing industry among regions and building a more perfect and close pharmaceutical innovation cooperation network. METHODS :Based on China ’s pharmaceutical manufacturing cooperation patent data published by the State Intellectual Property Office ,the main cross-region cooperation patents among 31 provinces,autonomous regions and municipalities in China in 2016 were extracted ;based on literature review ,some hypotheses were put forward about the factors that may affect the cross regional innovation cooperation of Chinese pharmaceutical manufacturing industry. Taking the provincial R&D cooperation intensity as the dependent variable and the above influencing factors as the independent variables ,QAP analysis method was used to establish the model for data analysis. RESULTS & CONCLUSIONS :Differences in regional economic GDP ,geographic distance ,economic distance ,technical distance,and whether Beijing or Shanghai are involved in the cooperation area all have an impact on cross-regional innovation cooperation in the pharmaceutical manufacturing industry. Large regional economic GDP difference is conducive to promoting cooperation. Developed regions represented by Beijing and Shanghai have strong radiating effects and can significantly promote cooperation. Geographical distance and economic distance have a negative effect on cross-regional innovation cooperation in pharmaceutical manufacturing ,while technological distance has positive effect.