1.Clinical studies of doppler ultrasound guidance interventional radiofrequency ablation in treatment of benign thyroid nodule
Yangsen LI ; Senyuan LIU ; Liwen LI ; Lijun FU ; Jianhua LI ; Xinguang QIU
International Journal of Surgery 2016;43(2):92-94,封3
Objective To explore the clinical results of benign thyroid nodule by ultrasound guided interventional radiofrequency ablation(RFA).Methods The radiofrequency ablation therapy was utilized to treat 129 patients with 149 thyroid nodules.The size and the related complications were observed during the follow-up.Using the t-test of paired design,the nodules volume decreased rate were calculated.Results At the 3rd and the 6th month after operation,all thyroid nodules in size to differert degree (P <0.05).Six patients felt pain in the neck.The pain was alleviated after ablation.Two patients had skin puncture site redness,which was cured after anti-inflammation treatment.There was no skin burn,perforation of the esophagus,trachea injury,hoarseness,bucking and other complications.Conclusions Ultrasound-guided RFA may be an effective and useful nonsurgical alternative in the treatment of thyroid nodules.It is clinically prospective for application.
2.Comparison of dose distributions among five radiotherapy apparatuses in stereotactic body radiation therapy for pancreatic cancer
Yangsen CAO ; Jianying ZHANG ; Tingting LI ; Jianjian QIU ; Libo ZHANG ; Yayun ZHUANG ; Yang SU ; Xiaojing GUO ; Huojun ZHANG
Chinese Journal of Radiation Oncology 2021;30(2):156-163
Objective:To compare the dose distribution among CyberKnife, Tomotherapy, Edge, Triology and γ-knife in stereotactic body radiation therapy (SBRT) for pancreatic cancer.Methods:Clinical data of 10 panreatic cancer patients receiving CyberKinife treatment were retrospectively analyzed. The treatment plans were designed by five apparatuses from five centers according to the uniform requirement. All plans were transferred to MIM system for the extraction of parameters, which mainly included D min, D mean and D max of PTV, conformity index (CI), new conformity index (nCI), homogeneity index (HI), gradient index (GI), coverage, D max and dose-volume of the stomach and bowel. Results:The best CI and nCI were obtained in Triology ( P<0.001), and the worst HI was found in γ-knife ( P<0.001). The best GI was found in CyberKnife, followed by γ-knife and Tomotherapy, and Edge showed the worst GI ( P<0.001). The highest D min of PTV was found in both Edge and Triology, while lower D min of PTV was found in CyberKnife and Tomotherapy ( P<0.001). Additionally, γ-knife provided the highest D mean and D max of PTV ( P<0.001). Regarding the organs at risk, the lowest D max and D 5cm 3 of the bowel ( P<0.001), D max of the stomach ( P=0.003), D max( P=0.001), D 5cm 3 ( P<0.001) and D 10cm 3 ( P=0.005) of the duodenum, D max( P<0.001) and D 0.35cm 3 ( P<0.001) of the spinal cord were found in CyberKnife. The highest D max of the bowel was found in γ-knife. Furthermore, the highest D 5cm 3 of the duodenum was demonstrated in Edge ( P<0.001) and Tomotherapy provided the highest D max( P<0.001) and D 0.35cm 3 of the spinal cord ( P<0.001). Conclusions:All five radiotherapy apparatuses can meet the requirement of SBRT for pancreatic cancer. More rapid dose fall-off could be obtained via CyberKnife and γ-knife. Triology and Edge provide better target conformity. CyberKnife can better protect the gastrointestinal tract.
3.Clinical features and prognostic factors of extrathyroidal extension in differentiated thyroid carcinoma
Qi HE ; Lijun FU ; Liwen LI ; Hongting LI ; Yangsen LI ; Xinguang QIU
Chinese Journal of Endocrine Surgery 2021;15(4):377-381
Objective:To investigate the risk factors related to extrathyroidal extension (ETE) of differentiated thyroid carcinoma (DTC) and the specific effects on the prognosis.Methods:The clinical data of 592 patients with newly diagnosed DTC admitted to our hospital from Jun. 2015 to Jun. 2016 were retrospectively analyzed. The data including the maximum tumor diameter and lymph node metastasis were collected, and the survival data were followed up. Chi-square test and Logistic regression were used to analyze the risk factors associated with ETE. Kaplan-Meier method and Cox proportional risk model were used to analyze the effect of ETE on disease-free survival.Results:There were 100 ETE of 592 DTC patients (16.9%) . Univariate analysis showed that the risk factors for ETE were the largest tumor diameter ≥2 cm, multiple lesions, and lymph node metastasis in the lateral cervical region ( P<0.01) . The follow-up time was 29 to 64 months, and the median follow-up time was 60 months. The 3-year and 5-year DFS rates of patients with DTC and ETE were 86.9% and 83.2% respectively, which were significantly lower than those of patients without ETE ( P<0.001) . Univariate analysis showed that ETE ( P<0.001) was a risk factor for postoperative recurrence in patients with DTC. Cox multivariate regression showed that ETE (HR: 10.564, 95% CI 3.712-30.063, P<0.001) was an independent risk factor for postoperative recurrence in patients with DTC. Conclusions:DTC accompanied by ETE is associated with risk factors such as large tumor diameter and multiple lesions, which has a lower 5-year DFS. Patients with the above characteristics should consider the possibility of ETE before surgery, and focus on long-term follow-up after surgery.
4.The application of different Auto-shells and optimization steps of CyberKnife treatment plans for pancreatic cancer
Yangsen CAO ; Jian LI ; Chunshan YU ; Yongjian SUN ; Xiaoping JU ; Xiaofei ZHU ; Yangyang GENG ; Yin TANG ; Huojun ZHANG
Chinese Journal of Pancreatology 2018;18(1):35-38
Objective To propose the method of dose distribution calculated by one-step optimization with 7 shells (Cao method) and compare with that by three-step optimization with 4 shells (Blanck method) and CyberKnife treatment plans for pancreatic cancer. Methods 20 cases of pancreatic cancer who underwent CyberKnife treatment were retrospectively analyzed,and CT was performed to localize and delineate the target area and endangering organs. Dosage was optimized and evaluated with Blanck method and Cao method. The planning target volume (PTV) conformity index (CI), new conformity index (nCI), homogeneity index (HI),gradient index (GI), coverage, dose-volume and doses to organs at risk were compared. Results Compared with Blanck method, CI (1.11 ± 0.05 vs 1.15 ± 0.05), nCI (1.20 ± 0.06 vs 1.23 ± 0.06), coverage [(92.48 ± 1.85)% vs (93.53 ± 2.15)%], volumes encompassed by 100% and 30% prescription dose line (36.46 ± 16.64 vs 38.19 ± 17.68; 286.19 ± 126.52 vs 320.93 ± 154.82) and monitor unit (56 369 ± 20 019 vs 57 814 ± 20 531) were significantly decreased,while GI was increased (3.22 ± 0.19 vs 3.11 ± 0.19), and all the differences were statistically significant (P<0.05). Additionally, Dmax of the intestine (21.17 ± 2.90 vs 20.63 ± 3.13), D10cc of the stomach (12.78 ± 2.57 vs 13.11 ± 2.43), D5ccof the duodenum (11.01 ± 3.45 vs 11.50 ± 3.25), D10ccof the duodenum (9.30 ± 3.31 vs 9.78 ± 3.07) and D0.35ccof the spinal cord (6.09 ± 0.98 vs 6.59 ± 0.92) were all significantly decreased (P<0.05). No significant differences were found on other parameters. Conclusions Better dose distributions are accessible by one-step optimization with 7 shells in CyberKnife treatment plans for pancreatic cancer.
5.Dosimetry advantage of respiratory gating in the treatment of hepatocellular carcinoma with large segmentation
Ziyin CHEN ; Yanchun BAI ; Yangsen CAO ; Jian LI ; Lili XU ; Qiushuang ZHAO ; Yang WANG
Practical Oncology Journal 2019;33(6):536-539
Objective The aim of this study was to investigate the dosimetric advantages of Gating in the treatment of prima-ry hepatic cancer with large segmentation. Methods A retrospective analysis of 10 patients with primary liver cancer from August 2017 to November 2018 after interventional therapy was performed using three consecutive phases of end-tidal phase to achieve pa-tient-controlled large-segment radiotherapy. Ten patients underwent 4DCT localization scan,and 10 respiratory phase sequences were reconstructed by respiratory wave-form,and the images were transmitted to the MIM6. 7. 6 workstation. In the MIM workstation, full-time phase maximum density projection(MIP-10),full-time phase average density projection(Mean-10),end-expiration 3 phase maximum density projection(MIP-3) and end-expiration 3 phase average density projection( Mean-3) were generated re-spectively,where MIP was used for target delineation and Mean for dose calculation. The radiotherapy doctor delineated IGTV-10 and IGTV-3 on the MIM workstation,and released CTV-10,CTV-3,PTV-10 and PTV-3 to compare the volume differences of the target area. After the target area was drawn,the image was transmitted from the MIM workstation to the Eclipse treatment planning sys-tem,and the full-time phase plan(Plan-10)with the same conditions and three consecutive phase-phase gating plans(Plan-3) were prepared. The prescriptive dosage was given at 50 Gy/10 f/2weeks. Comparing the HI and CI of the target area,the comparison of organs at risk included: the average dose of liver Dmean,the irradiation volume of liver less than 15Gy,the Dmax of small intestine, the Dmax of colon, the Dmax of stomach, the average dose of the kidney Dmean, the heart Dmax, and the spinal cord Dmax. Results The volume of the target area delineated at the end of expiratory phase was less than that of the target area outlined by the full-time phase in IGTV,CTV and PTV,and the difference was statistically significant(P<0. 05). In the two groups of seven field coplanar lage-segment radiotherapy plans,the 3-phase respiratory gating plan significantly reduced the dose of the organs at risk, and the difference was statistically significant(P<0. 05). At the same time,there was no statistically difference in the HI and CI be-tween of the two groups(P>0. 05). Conclusion The gated target area delineation and planning design of the three consecutive pha-ses of end-tidal phase reduce the volume of IGTV,CTV and PTV target regions compared with the selection of full-time phase,and have obvious advantages in the planned dosimetry. The irradiation dose that threatens the organs is worthy of being promoted and ap-plied in the large-scale radiotherapy of liver cancer.
6.Comparisons of dose distributions between IMPT and VMAT for pancreatic cancer
Yangsen CAO ; Zuofeng LI ; Ning XU ; Xiaojing GUO ; Huojun ZHANG
Chinese Journal of Radiological Medicine and Protection 2022;42(2):103-109
Objective:To compare dose distributions of hypofractionated radiotherapy for pancreatic cancer between IMPT and VMAT.Methods:Ten pancreatic cancer cases were included in this retrospective study. Photon (Edge) and proton (Proteus?PLUS) plans were designed by Eclipse and RayStation TPS, respectively. All plans were transferred to MIM system for extraction of parameters, which included Dmin, Dmean and Dmax of PTV, conformity index (CI), new conformity index (nCI), homogeneity index (HI), gradient index (GI), coverage, Dmax and dose-volume of the organs at risk (OARs). Results:There was no significant difference in CI between the two groups. The higher PTV Dmin, Dmean, Dmax, D98%, D2%, HI, coverage and the better GI, D2 cmwere found in VMAT ( t/ Z=-4.63-5.32, P<0.05). The lower 10%_PD was found in IMPT ( t=-7.47, P<0.05). Regarding the OARs, Dmax of the intestine, stomach, and duodenum and Dmean of the left kidney were similar between two groups without significant difference ( P>0.05). The D5 cm 3 of the intestine, D10 cm 3 of the stomach, D5 cm 3 and D10 cm 3 of the duodenum, D2/3 of the left kidney, Dmean and D2/3 of the right kidney were lower in IMPT than those in VMAT ( t/ Z=-8.12--2.60, P<0.05). However, the Dmax and D0.35 cm 3 of the spinal cord were higher in IMPT than those in VMAT ( t=7.30, 6.77, P<0.05). Conclusions:Both of hypofractionated radiotherapy plans of pancreatic cancer designed by VMAT and IMPT could meet clinical needs. No significant difference was found in Dmax of the adjacent gastrointestinal tracts between the two groups. While IMPT had the advantage over VMAT in the case of lower dose-volumes of the gastrointestinal tracts. Nevertheless, less protections of the OARs in front of the tumor volume could be provided by IMPT compared with VMAT.
7.Inhalation of Shin-I essential oil enhances lactate clearance in treadmill exercise.
Hsuan-Ying CHEN ; Ming-Fu WANG ; Jun-Ying LIN ; Ying-Chieh TSAI ; Fu-Chou CHENG
Asian Pacific Journal of Tropical Biomedicine 2014;4(2):158-163
OBJECTIVETo evaluate the effect of Shin-I essential oil inhalation on blood lactate changes in rats subjected to treadmill exercise.
METHODS: Adult male Sprague Dawley rats (n=12) were randomly divided into the control or the Shin-I group. Rats were subjected to a treadmill exercise program (15 m/min for 30 min). After exercise, rats were exposed to 200 µL of water or Shin-I essential oil, respectively, using a nebulizer for 180 min during the recovery period. Blood samples were collected every 15 min. Blood glucose and lactate concentrations were determined in a CMA 600 analyzer.
RESULTS: The basal glucose and lactate levels were no significantly different between two groups. After exercise, glucose levels were slightly increased to about 110%-120% of the basal level in both groups. Lactate levels of both groups reached to 110%-140% of basal levels during exercise. In the recovery period, lactate levels further increased to 180% of the basal level and were maintained at a plateau in the control group. However, lactate levels gradually decreased to 60%-65% of the basal level in the Shin-I group. Lactate clearance was significantly enhanced after Shin-I essential oil inhalation.
CONCLUSIONS: Our results provide evidence that Shin-I essential oil inhalation may accelerate recovery after exercise in rats.