2.Early Polyethylene Wear following TKA: A Report of Three Cases.
Jung Man KIM ; Yang Guk CHUNG ; Jin Suk EUN
Journal of the Korean Knee Society 1999;11(1):122-127
Polyethylene wear is one of the major problems following total knee arthroplasty. Many factors affect the degree and the pattern of polyethylene wear. We experienced three cases of early catastrophic poly- ethylene wears. All cases showed flexion contracture with severe genu varum deformity and total knee arthroplasty was performed with Advantim total knee prostheses in all cases. Postoperatively, bony align- ment and ligament balancing were good in all cases. However, in 12 to 22 months later, lateral subluxa- tion and valgus instability were developed with early catastrophic polyethylene wear especially in the medial compartments. Flat surface geornetry of polyethylene might be responsible for the development of lateral subluxation and early catastrophic wears. From these experience, we concluded that the mediolat- eral as well as anteroposterior dishing is essential for the stability of the artificial joint and prevention of early rapid wear of polyethylene articular inserts following total knee arthroplasty.
Arthroplasty
;
Congenital Abnormalities
;
Contracture
;
Genu Varum
;
Joints
;
Knee
;
Knee Prosthesis
;
Ligaments
;
Polyethylene*
3.Anesthesia for ambulatory pediatric patients.
Jung Soo YOON ; Tae Hoon KANG ; Hong Suk YANG
The Korean Journal of Critical Care Medicine 1993;8(1):53-58
No abstract available.
Anesthesia*
;
Humans
4.Polycystic ovary in torsion combined with stage in endometrial carcinoma.
Jung In YANG ; Suk Jung KIM ; Byung Seok LEE ; Dong Jei CHO ; Kook LEE ; Chan Ho SONG
Korean Journal of Obstetrics and Gynecology 1991;34(10):1481-1487
No abstract available.
Endometrial Neoplasms*
;
Female
;
Ovary*
5.Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.
Jung Woo KOH ; Jae Ho YANG ; Jung Suk HAN ; Jai Bong LEE ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2009;1(2):107-112
STATEMENT OF PROBLEM: Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant. PURPOSE: The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model. MATERIAL AND METHODS: Three test groups were prepared: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion. RESULTS: The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P < .05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P > .05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P > .05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups. CONCLUSION: The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.
Dental Implants
;
Imidazoles
;
Immersion
;
Nitro Compounds
;
Osseointegration
;
Rabbits
;
Tibia
;
Titanium
;
Torque
6.Laryngeal adjustments for Korean stops: acoustic, electromyographicand fiberscopic analysis.
Ki Hwan HONG ; Dong Suk CHON ; Young Jung KIM ; Kil Yang JUNG
Korean Journal of Otolaryngology - Head and Neck Surgery 1992;35(6):770-782
No abstract available.
Acoustics*
7.Laryngeal adjustments for the Korean stops affricates and fricatives: electromyographic studies.
Ki Hwan HONG ; Dong Suk CHON ; Mi Jung KIM ; Kil Yang JUNG ; Young Ki KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 1991;34(5):1008-1017
No abstract available.
8.Two Cases of Meconium Peritonitis.
Hye Jin LIM ; Hae Young KIM ; Yang Suk CHOI ; Jung Woo YANG
Journal of the Korean Pediatric Society 1986;29(6):92-96
No abstract available.
Meconium*
;
Peritonitis*
9.The Effect of Overweight and Pregnancy on Endocrinologic Features and Glucose Metabolism in Patients with Polycystic Ovarian Syndrome.
Kyung Joo HWANG ; Kie Suk OH ; Sei Kwang KIM ; Hyuck Chan KWON ; Young Han PARK ; Jung In YANG ; Hee Suk RHYU
Korean Journal of Obstetrics and Gynecology 1999;42(3):606-613
OBJECTIVE: The purpose of this study attempts to determine the endocrinologic characteristics and changes in glucose metabolism before/during pregnancy according to different body weights in women with Polycystic ovarian syndrome (PCOS). METHODS: 94 women dia with PCOS were evaluated through measuring serum hormone levels and oral glucose tolerance tests preconceptionally and gestationally. RESULTS: In patients who were of normal weight showed significantly increased serum LH levels compared to those who were overweight (12.8+/-0.9 Vs. 7.1+/-0.8 mIU/ml, p= 0.000), and the serum levels of insulin was increased significantly in the overweight group (7.1+/-0.7 Vs. 15.2+/-2.8 ulU/ml, p= 0.000). the IGFBP-I (32.8+/-10.6 Vs. 8.3+/-2.5 ng/ml, p=0.034) and SHBG (55.8+/-4.2 Vs. 37.1+/-3.1 nmol/ml, p= 0.001) were significantly lower in the ovnweight group. The oral glucose tolerance test before/after pregnancy showed increased frequency of abnormal glucose metabolism, in both of the non-obese group (38.8%, 26,9%) and the obese group (64.2%, 53.9%) compared with normal population. CONCLUSION: It is thought that in the normal weight group with polycystic ovarian syndrome androgen production is stimulated in the theca cells by abnormally high LH secretion, while in the overweight group the hyperinsulinemia state which decreases the SHBG and IGFBP-I, lead to increase biologically active hee androgens and IGF-I and increase insulin binding to its receptor. And during/before pregnancy, women with PCOS showed that incidence of abnormal glucose metabolism was significantly increased in both of non-obese and obese groups.
Androgens
;
Body Weight
;
Female
;
Glucose Tolerance Test
;
Glucose*
;
Humans
;
Hyperinsulinism
;
Incidence
;
Insulin
;
Insulin-Like Growth Factor I
;
Metabolism*
;
Obesity
;
Overweight*
;
Polycystic Ovary Syndrome*
;
Pregnancy*
;
Theca Cells
10.COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN.
Young Joo CHA ; Jae Ho YANG ; Sun Hyung LEE ; Jung Suk HAN
The Journal of Korean Academy of Prosthodontics 2001;39(6):599-610
Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively (PFM, Empress staining technique, Empress 2 layering technique, and Targis-Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy (Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(+/-906)N; for Empress staining technique the fracture strength was 1697(+/-604)N; for Empress 2 Layering technique the fracture strength was 1781N(+/-400)N, and the fracture strength for Targis-Vectris was 3093(+/-475)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers torn off from Vectris.
Alloys
;
Ceramics*
;
Crowns*
;
Dentists
;
Esthetics
;
Fingers
;
Humans
;
Hypersensitivity
;
Lithium
;
Microscopy, Electron, Scanning
;
Shoulder
;
Stainless Steel
;
Water