1.The role of hyperhomocystinemia in the oxidative stress and inflammation injury mechanism of ischemic injury in cerebral infarction
Rong XUE ; Dong-Mei WANG ; Yan CHENG ;
Chinese Journal of Neurology 2005;0(11):-
Objective To explore the mechanism of cerebral infarction caused by hyperhomocystinemia.Methods A hundred and nineteen paitents with acute cerebral infarction were chosen for case group.According to their levels of plasm total homocystine,they were divided into two groups: hyperhomocystinemia group and nonhyperhomocystinemia group.Forty patents without cerebrovascular disease,hepatophy,nephrosis and thyroid gland disease were chosen as control subjects.Plasm levels of total homocystine,serum levels of MDA and IL-8 were measured respectively,their correlations were also studied.Results Plasma levels of tHcy(?mol/L)and serum levels of MDA(nmol/L)and IL-8 (ng/ml)showed a significant increase in case group(19.97,4.41?0.84,0.23?0.08)in comparison with control subjects(9.83,3.24?0.64,0.12?0.08),t values were 8.139,8.021,7.767 respectively(P
2.Clinical Observation of Chaihu Shugan Powder Combined with Clonazepam in the Treatment of Liver Qi Stagnation Type Anxiety
Hongyan CHENG ; Yan MEI ; Hongwei DU
China Pharmacy 2016;27(17):2407-2409
OBJECTIVE:To observe clinical efficacy and safety of Chaihu shugan powder combined with clonazepam in the treatment of liver qi stagnation type anxiety. METHODS:96 patients with liver qi stagnation type anxiety were randomly divided in-to observation group and control group,with 48 cases in each group. Control group was given Clonazepam tablet with initial dose of 0.5 mg,increasing to 4.0 mg gradually,tid;observation group was additionally given Chaihu shugan powder 300 ml,bid,on the basis of control group. Both groups were treated for 6 weeks. Clinical efficacy of 2 groups were observed,and HAMA and SAS were observed before and after treatment;the incidence of ADR were compared between 2 groups. RESULTS:The total effective rate of observation group(97.92%)was significantly higher than that of control group(83.33%),with statistical significance(P<0.05). There was no statistical significance in HAMA and SAS between 2 groups before treatment(P>0.05);HAMA and SAS of 2 groups decreased significantly 1,3 and 6 weeks after treatment,and the observation group was lower than the control group, with statistical significance(P<0.05). There was no statistical significance in the incidence of ADR between 2 groups(P>0.05). CONCLUSIONS:Chaihu shugan powder combined with clonazepam is effective,improve patient anxiety and safe in the treatment of liver qi stagnation type anxiety.
3.Correlative Analysis on Human Leukocyte Antigen-DQ Gene Susceptibility for Autoimmune Polyglandular Syndrome,Type 1 Diabetic Mellitus and Autoimmune Thyroid Disease
di, WU ; cheng, ZHU ; chun-xiu, GONG ; yan-mei, SANG
Journal of Applied Clinical Pediatrics 2006;0(14):-
Objective To evaluate the associations of human leukocyte antigen(HLA)-DQ gene with autoimmune polyglandular syndrome(APS),type 1 diabetic mellitus(T1DM) and autoimmune thyroid disease(AITD).Methods Fifteen cases of APS,29 cases of T1DM and 40 cases of AITD were selected as research subjects,while 27 healthy children were selected as controls.The DQA1 and DQB1 alleles were determined by polymerase chain reaction(PCR) and sequence-based typing method.The difference of their frequency in children and adolescents was analyzed.Results Compared with controls,APS and T1DM patients had increased frequency of subjects with DQA1*0301,0501(all P
4.Pharmacokinetics of epirubicin hydrochloride long-circulating thermosensitive liposomes in rat plasma.
Yan WU ; Fucheng ZHANG ; Cheng WU ; Xingguo MEI ; Wanliang Lü
Acta Pharmaceutica Sinica 2010;45(3):365-70
To develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of epirubicin hydrochloride (EPI) in rat plasma, daunorubicin hydrochloride was used as internal standard. The plasma samples were deproteinated with methanol, and separation was performed on a reversed-phase CAPCELL PAK C18 column (3.0 mm x 50 mm, 3 microm). The mobile phase contained methanol-0.1% formic acid (80:20). Detection was carried out by multiple reaction monitoring on a HP1200-6410 QQQ LC/MS system. Different preparations of EPI solution, EPI-LIP (EPI-liposome) and EPI-LTSL (EPI-thermosensitive liposome) was administered in rats by i.v with the same dosage (12 mg kg(-1)). The pharmacokinetic model and parameters were fitted and calculated by the DAS ver2.0 software. The calibration curve was linear in the range of 0.01-50 microg mL(-1). The limit of quantification was 0.01 microg mL(-1). RSDs of intra- and interbatch precisions were all less than 11.9%. The average extract recovery was 89.3% and 92.1%, respectively. The pharmacokinetics of EPI in rats with all preparations were fitted to three compartments, which all fast distributed and slowly eliminated. The t1/2 alpha, t1/2 beta, t1/2 gamma, AUC(0-infinity), and MRT(0-infinity) of EPI-LTSL group were 7.5, 1.3, 12.6, 12.9, 3.7 times those of EPI solution group; and 1.6, 1.4, 12.3, 2.9, 2.6 times those of EPI-LIP group. Moreover, the CL of the latter two groups was about 13.4 times of the former EPI-LTSL group. EPI-LTSL can significantly improve AUC and prolong the circulation time of EPI in rat plasma.
5.Experiment study on anti-nonenzyme glycosylation effect of Grape Seed Proanthocyanidin Extract in Diabetic Rats
Yan ZHOU ; Yabing MA ; Haiqing GAO ; Mei CHENG ; Beian YOU
Chinese Journal of Geriatrics 2001;0(01):-
0.05) during the experiment. The TC of middle dose GSPE group was marked ly different compared with that of normal group(P
6.In vitro release behavior of doxorubicin-loaded injectable microspheres
Cheng WU ; Yan WU ; Yuemei YU ; Xingguo MEI
Academic Journal of Second Military Medical University 1981;0(03):-
Objective:To evaluate the in vitro release behavior of doxorubicin(Dox)-loaded microspheres and the stability of Dox during encapsulation process and in vitro release.Methods: Dox-loaded microspheres were prepared by double emulsion(W/O/W) method with poly(lactic-co-glycolic acid)(PLGA) as the carrier material.The physical and chemical characteristics of microspheres,including the mean diameter,morphology,drug entrapment efficiency and loading rate,were evaluated.The in vitro release behavior and its influencing factors were determined by ultraviolet spectrophotometry.Dox stability was evaluated by HPLC method during the encapsulation process and in vitro release.Results: The prepared microspheres had a complete spheric shape and dispersive quality.The mean diameter of the microspheres was 85 ?m;the drug entrapment efficiency was 95.1%;and the loading rate was 14.8%.Releasing rate of the microspheres slowed down with the increase of PLGA concentration and the decrease of W/O value.The encapsulation process had no obvious effect on the stability of Dox,while Dox degraded during in vitro release as the prolongation of time.On day 10,the peak area of degraded material accounted for 2.46%.Conclusion: Dox can be encapsulated in the microspheres by double emulsion method and different release rates of Dox can be achieved by adjusting PLGA concentration and W/O volume ratio.
7.Pharmacokinetics of epirubicin hydrochloride long-circulating thermosensitive liposomes in rat plasma.
Yan WU ; Fu-cheng ZHANG ; Cheng WU ; Xing-guo MEI ; Wan-liang LÜ
Acta Pharmaceutica Sinica 2010;45(3):365-370
To develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of epirubicin hydrochloride (EPI) in rat plasma, daunorubicin hydrochloride was used as internal standard. The plasma samples were deproteinated with methanol, and separation was performed on a reversed-phase CAPCELL PAK C18 column (3.0 mm x 50 mm, 3 microm). The mobile phase contained methanol-0.1% formic acid (80:20). Detection was carried out by multiple reaction monitoring on a HP1200-6410 QQQ LC/MS system. Different preparations of EPI solution, EPI-LIP (EPI-liposome) and EPI-LTSL (EPI-thermosensitive liposome) was administered in rats by i.v with the same dosage (12 mg kg(-1)). The pharmacokinetic model and parameters were fitted and calculated by the DAS ver2.0 software. The calibration curve was linear in the range of 0.01-50 microg mL(-1). The limit of quantification was 0.01 microg mL(-1). RSDs of intra- and interbatch precisions were all less than 11.9%. The average extract recovery was 89.3% and 92.1%, respectively. The pharmacokinetics of EPI in rats with all preparations were fitted to three compartments, which all fast distributed and slowly eliminated. The t1/2 alpha, t1/2 beta, t1/2 gamma, AUC(0-infinity), and MRT(0-infinity) of EPI-LTSL group were 7.5, 1.3, 12.6, 12.9, 3.7 times those of EPI solution group; and 1.6, 1.4, 12.3, 2.9, 2.6 times those of EPI-LIP group. Moreover, the CL of the latter two groups was about 13.4 times of the former EPI-LTSL group. EPI-LTSL can significantly improve AUC and prolong the circulation time of EPI in rat plasma.
Animals
;
Antibiotics, Antineoplastic
;
administration & dosage
;
blood
;
pharmacokinetics
;
Area Under Curve
;
Chromatography, Liquid
;
Drug Carriers
;
Epirubicin
;
administration & dosage
;
blood
;
pharmacokinetics
;
Liposomes
;
blood
;
pharmacokinetics
;
Male
;
Rats
;
Rats, Sprague-Dawley
;
Reproducibility of Results
;
Sensitivity and Specificity
;
Tandem Mass Spectrometry
8.The protective effect of Yuyin Ruangan Decoction on experimental hepatic injury.
Zhi-wang WANG ; Xue-feng LU ; Hai-yan TUO ; Xiao-li CHENG ; Mei GUO
Chinese Journal of Applied Physiology 2015;31(1):76-79
OBJECTIVETo investigate the protective effects of Yuyin Ruangan Decoction(YRD, traditional Chinese medicine) on experimental hepatic injury in mice.
METHODSThe mice were randomly divided into control group, model group and YRD low, middle and high dose group(n = 11). By ip injection of D-GalN, CCk or thioacetamide (TAA), three models of hepatic injury mice were established to investigate the effects of YRD through detecting the indexes of liver function in serum and, the content of antioxidant system in the hepatic tissue.
RESULTSYRD could decrease the content of alanine aminotransferase (ALT)and aspartate aminotransferase (AST) in serum and that of malonaldehyde (MDA) in the hepatic tissue, upregulate the activity of superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) in the hepatic tissue. Furthermore, the above effects were dosedependent in a certain degree. CoNCLUSION: YRD has some protection effects on the model of experimental hepatic injury in mouse.
Alanine Transaminase ; blood ; Animals ; Antioxidants ; metabolism ; Aspartate Aminotransferases ; blood ; Chemical and Drug Induced Liver Injury ; drug therapy ; Drugs, Chinese Herbal ; pharmacology ; Glutathione Peroxidase ; metabolism ; Liver ; drug effects ; enzymology ; Malondialdehyde ; metabolism ; Mice ; Superoxide Dismutase ; metabolism
9.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
10.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.