1.Diagnostic Value of 4 μg/mL vancomycin screening plate for vancomycin-non-susceptible Staphylococcus aureus:a Meta-analysis
International Journal of Laboratory Medicine 2015;(16):2321-2323
Objective To evaluate the diagnostic accuracy of 4 μg/mL vancomycin screening plate (4VA)for vancomycin-non-susceptible Staphylococcus aureus.Methods The diagnosis trials on 4VA for vancomycin-non-susceptible Staphylococcus aureus were searched in the databases such as PubMed(1 966 to Aug.2013),The Cochrane Library(the second phase of 2013),ISI Web of Knowledge(1 980 to Aug.2013),CNKI (1 964 to Aug.2013),VIP (1 989 to Aug.2013)and Wanfang(1 998 to Aug.2013),mean-while the manual.Two reviewers evaluated the quality of the included trials according to the quality assessment of diagnostic accu-racy studies,and then meta-analysis was performed using Meta-Disc 1.4 software.Results A total of 3 trials involving 974 partici-pants were included.The results of meta-analysis showed that the weighted sensitivity,specificity,positive likelihood ratio,negative likelihood ratio and diagnostic odds ratio,were 0.805 [95%CI (0.047 to 0.563)],0.921 [95%CI (0.901 to 0.938)],10.804 [95%CI (5.5 1 1 to 21.181)],0.1 62 [95%CI (0.71 to 1.0)]and 69.721 [95%CI (1 1.740 to 414.06)]respectively.Conclusion 4VA for vancomycin-non-susceptible Staphylococcus aureus has a very high specificity and sensitivity,so 4VA could be used to creening plate (4VA)for vancomycin-non-susceptible Staphylococcus aureus in clinic.
2.Application of LogMiner in No.1 Military Medical Project
Jiangtao ZHANG ; Yabin KANG ; Dongmei CHENG
Chinese Medical Equipment Journal 2003;0(10):-
Objective To quickly pinpoint and correct errors in the application level in No.1 Military Medical Project. Methods LogMiner, a powerful tool provided by Oracle was used to mine and analyze the redo log files produced by oracle database in No.1 Military Medical Project. The basic concept, configuration and usage of LogMiner were described through an example of the Register Program in No.1 Military Medical Project. Results The errors made by Register Program was quickly pinpointed and then corrected by SQL statements provided by UNDO_VALUE field. Conclusion The method using LogMiner to pinpoint and correct the errors in the application level in No.1 Military Medical Project is simple, accurate and convenient. It should be a basic technique for maintenance personnel of hospital information system.
3.Homeopathic closed leverage anatomical plate with compression bolt for treatment of displaced intra-articular calcaneal fractures
Qingxian WANG ; Yabin ZHOU ; Shimeng ZHAO ; Cheng ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2017;33(7):602-607
Objective To compare the treatment of displaced intra-articular calcaneal fractures by homeopathic closed leverage anatomical plate with compression bolt through small posterior lateral approach vs.traditional open reduction and internal fixation.Methods A retrospective case control study was made on 98 cases of displaced intra-articular calcaneal fractures admitted from September 2012 to May 2015.According to the random number table,the subjects were assigned to homeopathic closed leverage anatomical plating with compression bolt through small posterior lateral approach (experiment group,58 cases,66 sides) and open reduction and internal fixation through L-shape approach (control group,40 cases,45 sides).Experiment group consisted of 50 male and eight females cases aging from 27-56 years (mean,41.9 years),and the Sanders classification was 40 cases of type Ⅱ,24 type Ⅲ and two type Ⅳ.Control group consisted of 36 male and four female cases aging from 25-58 years (mean,43.7 years),and the Sanders classification was 25 cases of type Ⅱ,18 type Ⅱ and two type Ⅳ.Operation time,bone reduction,postoperative Bohler's angle,width of the calcaneum,and incision healing were recorded.Functional outcomes were evaluated with Maryland hindfoot scoring system at last follow-up.Results Operation time was (52.6 ± 11.2) min in experiment group,significantly shorter than that in control group [(86.4 ± 14.1) min] (P < 0.01).All cases were followed up from 18-50 months (mean,30.8 months).Reduction of the calcaneal posterior facet in 53 sides (80%) was graded as nearly anatomical in experiment group,and 38 sides (84%) in control group (P > 0.05).Postoperative Bohler's angle was (28.0 ± 6.2) ° in experiment group,and (26.8 ± 7.0) ° in control group (P > 0.05).Width of the calcaneum was (31.3 ±3.6)mm in experiment group and (34.9 ± 4.0)mm in control group (P < 0.01).All cases presented satisfactory shape of the calcaneus without lateral-side impact syndrome.No case had wound infection and incision-edge necrosis in experimental group,while two cases of superficial wound infection and three cases of incision-edge necrosis were found in control group (P < 0.01).At last follow-up,Maryland hindfoot score was (87.1 ± 7.6)points in experiment group and (84.9 ± 9.1)points in control group (P > 0.05).Conclusion Homeopathic percutaneous leverage and anatomical plate with compression bolt through small posterior lateral approach is an effective method for treatment of displaced intra-articular calcaneal fractures,for it has advantages of minimal invasion,less operation time,good reduction and function,and less wound complications.
4.Design, synthesis and evaluation of tacrine-methoxybenzene hybrids as cholinesterases inhibitors.
Wen LUO ; Yongmei ZHAO ; Zhen ZHANG ; Yabin SU ; Chaojie WANG
Acta Pharmaceutica Sinica 2012;47(7):916-21
A series of tacrine-methoxybenzene hybrids (5a-5i) were designed, synthesized and evaluated as inhibitors of cholinesterases (ChEs). All the compounds had better ChEs inhibitory activities than tacrine with IC50 values at the nanomolar range. Compound 5h exhibited the strongest inhibition on acetylcholinesterase (AChE) with an IC50 value of 6.74 nmol x L(-1) and compound 5f showed the most potent inhibition on butyrylcholinesterase with IC50 value of 3.83 nmol x L(-1). Kinetic and molecular modeling studies showed that these hybrids targeted both the catalytic active site and the peripheral anionic site of AChE.
5.Using bone marrow mesenchymal stem cells to treat liver diseases
Jian CHU ; Hualian HANG ; Yabin YU ; Shihai ZHANG ; Jianmin BIAN
Chinese Journal of Hepatobiliary Surgery 2012;18(7):564-566
Primary hepatocellular carcinoma progresses from liver fibrosis and cirrhosis to eventually result in liver failure and distant metastasis.Surgical resection is the preferred method of treatment for liver cancer while interventional treatment and liver transplantation are the choices to treat end-stage liver cancer.Unfortunately,partial hepatectomy and interventional treatment are not ideal due to the resulting consequence of hepatocyte dysfunction.Extensive clinical application of liver transplants is limited by the lack of available donors and high costs.Over the past decade,researches on bone marrow mesenchymal stem cells (BMSCs)have made remarkable achievements in the medical field.In this review,we summarize the recent progress of BMSCs in the treatment of liver diseases.
6.Research Progress and Application of Penetration Enhancers in TCM Transdermal Medicine Delivery Preparations
Juanling ZHANG ; Ying WANG ; Xingchen YAO ; Yabin DUAN ; Xiangyang LI
Chinese Journal of Information on Traditional Chinese Medicine 2015;(9):134-136
Because TCM transdermal medicine delivery preparations are hot spots in domestic researches, the rational application of penetration enhancers in prescriptions and the evaluation methods become increasingly important. This article reviewed the recent application of natural penetration enhancers and synthetic penetration enhancers in the prescription design of TCM transdermal medicine delivery preparations, and analyzed the existing problems and development prospects.
7.Assessment of bronchial and pulmonary blood supply in lung adenocarcinoma and squamous cell carcinoma using dual-input perfusion CT
Lei GAO ; Qing YANG ; Yabin HU ; Liang ZHANG ; Jianan REN
Chinese Journal of Medical Imaging Technology 2017;33(3):419-422
Objective To evaluate the dual blood supply of lung adenocarcinoma and squamous cell carcinoma using dualinput perfusion CT.Methods A total of 40 patients confirmed with lung cancer pathologically underwent CT perfusion (CTP) scanning.The pulmonary flow (PF),bronchial flow (BF),perfusion index (PI,PI=PF/[PF+BF])and tumor volume,location were measured and recorded by 2 experienced radiologists.The differences in CTP parameters between lung adenocarcinomas and squamous cell carcinomas,the central lung cancers and peripheral lung cancers were analyzed.The correlation between the tumor volume and CTP parameters was analyzed.Interobserver agreements were assessed with intraclass correlation coefficient (ICC).Results The average of PF,BF and PI of all 40 cases was (54.26± 21.07)ml/ (min · 100 ml),(64.41±22.06)ml/(min · 100 ml) and (43.38±16.07)%,respectively.Tumor histology was consistent with adenocarcinomas in 23 cases and squamous cell carcinomas in 17 cases,lung adenocarcinomas showed lower PI than that of squamous cell carcinomas (t=-2.196,P=0.034).There were 17 peripheral lung cancers and 23 central lung cancers,and the PI of the peripheral lung cancers was higher than that of the central lung cancer (t=2.305,P=0.027).No statistically significant differences were found for BF and PF between two types of lung cancers and central lung cancers and the peripheral cancers (all P>0.05).Tumor volume was negatively associated with PI (r =-0.39,P=0.01).Good agreement was found between the two observers,the ICC for BF,PF and PI was 0.97,0.93 and 0.91,respectively.Conclusion Dual-input CTP technique can be used to evaluate the differences of blood supply between different pathological types and locations of lung cancer,with PI depending both on tumor size and location.
8.Comparison of corneal ablation depth predictability between small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis for myopia
Wen, XU ; Yuehua, ZHOU ; Li, ZHANG ; Yabin, HU ; Yue, WANG
Chinese Journal of Experimental Ophthalmology 2017;35(6):532-536
Background Recently,small incision lenticule extraction (SMILE) procedure is used to correct myopia.The clinical safety and efficiency of SMILE have been approved,but its predictability to corneal ablation depth is brought into focus.Objective This study was to compare the predictability of ablation depth in central cornea between SMILE and femtosecond laser-assisted in situ keratomileusis (FS-LASIK) for myopia.Methods A nonrandomized controlled clinical study was performed.Two hundred and seventy eyes of 135 myopic patients who were going to receive corneal refractive surgery were included in Beijing Tongren Hospital from October 2015 to May 2016.SMILE and FS-LASIK were performed on 138 eyes of 69 patients and 132 eyes of 66 patients matched in demography respectively under the informed consent.Central corneal thickness was measured by RTVue FD-OCT before and 1 week after surgery.The refractive power,actual ablation depth (difference of central corneal thickness before and after surgery) and central corneal cutting error (difference between theoretically expected ablation depth and real ablation depth) were intergrouply compared,and the correlation of real ablation depth with theoretically expected ablation depth was assessed.Results No significant difference was found in spherical power,astigmatic power and spherical equivalent after surgery between SMILE group and FS-LASIK group (t =-1.826,-1.405,-1.420,all at P>0.05).The actual ablation depth was (76.96± 15.27)μm in the SMILE group,which was significant lower than (96.76± 16.52) μm of theoretically expected ablation depth (t =-23.016,P < 0.01);however,there was no significant difference in the FS-LASIK group between actual and expected ablation depth ([77.92 ± 18.69] μm versus [77.42± 15.60] μm) (t =-0.604,P =0.547).The central corneal cutting error was (20.55 ± 8.51) μm in the SMILE group and (7.17±5.97) μm in the FS-LASIK group,showing a significant difference between them (t=14.950,P<0.01).The positive linear correlations were seen between actual and expected ablation depth in both SMILE group and FS-LASIK group (r=0.799,0.867,both at P<0.01).The actual ablation depth was increased over expected ablation depth,with the regression equations of Y=3.892+0.749X in the SMILE group and Y=3.443 + 0.957X in the FS-LASIK group.Conclusions The actual corneal ablation depth is less than expected corneal ablation depth in SMILE procedure,while in FS-LASIK procedure,the actual corneal ablation depth appears to be consistent with the expected one,inferring a good predictability in corneal ablation depth in FS-LASIK surgery.
9.Effect of different angles of implanted screws on the stability of pedicle screw
Zhonghui PANG ; Miao LIU ; Yabin ZHANG ; Yongfeng YAO ; Shaokun PEI
Chinese Journal of Tissue Engineering Research 2015;(48):7765-7769
BACKGROUND:Some studies have showed that the accuracy and surgery outcome of the percutaneous pedicle screw implantation was superior to open surgery, but the relationship between the angle of pedicle screws and screw stability is stil unclear in previous studies. OBJECTIVE:To investigate the effect of different angles of implanted screws on the stability of pedicle screw. METHODS:A total of 30 vertebral specimens of adult pigs were selected and screws were implanted respectively according to different coronal and sagittal angles. The maximum pul-out strength of screws from each specimen was tested by machine. Load-displacement curves were drew and statistical y analyzed. RESULTS AND CONCLUSION:The maximum pul-out strength and maximum energy of screw with 10° and 15° coronal and sagittal angles implantation were significantly better than those of 0° angle group (P<0.05). When the stress exceeded the maximum pul-out strength, the pul-out strength of screw decreased gradual y. The curves in coronal and sagittal 10° and 15° angle groups was similar, and the slope was better than 0° angle group (P<0.05). These results confirm that the angle of the implanted screw provides effective assistance to the stability of percutaneous pedicle screw. After the looseness of the screws, the pul out strength shows a steady downward trend.
10.The manifestations and causes of non-pulmonary embolism inducedperfusion defects on dual-energy perfusion imaging using dual source CT
Yuanyuan GENG ; Peixiu LI ; Yabin JIAO ; Changming FENG ; Xincheng ZHANG ; Yanzong ZHANG
Journal of Practical Radiology 2017;33(8):1187-1190
Objective To analyze the causes and manifestations of non-pulmonary embolism induced perfusion defects (PDs) on dual-energy perfusion imaging (DEPI) using dual source CT.Methods Consecutive 208 patients without pulmonary embolism who underwent DEPI were reviewed retrospectively.The causes of PDs were analyzed by two radiologists, the pulmonary segment numbers, the proportion and the perfusion patterns of each case were recorded and analyzed respectively.Results 1 118 of 3 716 pulmonary segments showed the PDs.Among them, 752(67.26%), 36(3.22%), 308(27.55%) and 22(1.97%) pulmonary segments had PDs due to intra-pulmonary lesions, vascular diseases, artifacts and unidentifiable causes, respectively.In PDs resulted from intra-pulmonary lesions, vascular diseases and unidentifiable causes, three patterns (wedge-shaped, heterogeneous and regionally homogeneous) were identified,and most of those PDs were heterogeneous and regionally homogeneous, which were largely in accordance with the lesions showed on non-contrast enhanced scans.Artifacts included the beam hardening artifacts and artifacts caused by heart beat or diaphragmatic movement.The PDs caused by artifacts usually had particular locations and shapes.Conclusion Understanding of the manifestations and causes of PDs in patients without pulmonary embolism can improve the diagnosis accuracy of pulmonary embolism on DEPI.