1.Regulatory effect of electroacupuncture on heart and stomach of rats.
Bin-bin REN ; Zh YU ; Ya-li WANG ; Bin XU
Chinese Journal of Integrated Traditional and Western Medicine 2014;34(10):1212-1215
OBJECTIVETo explore different regulatory effects of electroacupuncture (EA) at the same acupoint on the heart and the stomach.
METHODSEighty male SD rats were randomly divided into eight groups equally, i.e., the Neiguan (PC6) group, the Quchi (LI11) group, the Tianshu (ST25) group, the Danzhong (RN17) group, the Zusanli (ST36) group, the Sanyinjiao (SP6) group, the Xinshu (BL15) group, and the Weishu (BL21) group, 10 in each group. The regulatory effects of EA (2/15 Hz, 3 mA, 2 min) at different acupoints on the gastric motility (intragastric pressure) and the cardiac function (the left ventricular pressure) were observed. The mean values of effect of two-min pre-EA and after-EA were compared.
RESULTSCompared with the pre-EA in the same group, the left ventricular pressure decreased in the Neiguan (PC6) group, the Quchi (LI11) group, the Danzhong (RN17) group, the Sanyinjiao (SP6) group, and the Xinshu (BL15) group (P <0.05). The intragastric pressure increased in the Quchi (LI11) group, the Zusanli (ST36) group, the Sanyinjiao (SP6) group, and the Xinshu (BL15) group, while it decreased in the Tianshu (ST25) group, the Danzhong (RN17) group, and the Weishu (BL21) group (P <0.05). The difference of the left ventricular pressure was sequenced from high to low as Xinshu (BL15) >Danzhong (RN17) >Neiguan (PC6) >Sanyinjiao (SP6) >Quchi (LI11). The difference of the intragastric pressure was sequenced from high to low as Tianshu (ST25) >Weishu (BL21) > Xinshu (BL15) > Danzhong (RN17) > Zusanli (ST36) > Sanyinjiao (SP6) > Quchi (LI11).
CONCLUSIONSEA at the same acupoint (2/15 Hz, 3 mA) showed different regulatory effects on the heart and stomach. There existed some difference in the direction and size due to the acupoint location, meridians, dominant nerve segment or relating organs. A fixed effect direction to the specific target was also shown.
Acupuncture Points ; Animals ; Electroacupuncture ; Heart ; physiology ; Male ; Meridians ; Rats, Wistar ; Stomach ; physiology
2.Accurate localization of pulmonary segments on pulmonary perfusion SPECT/CT imaging
Ya-bin, YU ; Qian, WANG ; Tie, WANG
Chinese Journal of Nuclear Medicine 2010;30(3):189-194
Objective To investigate the methods for localization of the lung segments on three-dimentional (3D) pulmonary perfusion SPECT/CT imaging.Methods Twelve healthy adults were recruited into this study.Lung segments were defined based on the anatomical criteria of CT on transaxial, sagittal and coronal images, including apical, posterior, anterior segments in right upper lobe ( RUL), lateral, medial segments in right middle lobe ( RML), superior, anterior basal, lateral basal, posterior basal segments in right lower lobe (RLL); apical posterior, anterior, superior lingual, inferior lingual segments of left upper lobe ( LUL), superior, medioanterior basal, lateral basal, posterior basal segments of left lower lobe (LLL).Results (1) Eleven typical sections were selected on transaxial SPECT pulmonary perfusion imaging:sternoclavicular joint, supra-arch vessels, aortic arch, azygous arch, right upper lobar bronchus, left upper lobar bronchus, middle lobar or lingual bronchus, basal trunk of bronchus, lower lobar vein, superior and inferior basal vein and basal vein.(2) Twelve typical sections were defined on sagittal imaging:left hilum, bifurcation of left principal bronchus, septa of left pulmonary artery, cardiac apex, the first and second sections left to cardiac apex; right hilum, bifurcation of intermite bronchus, interlobar artery, bifurcation of interlobar artery, the second and third sections right to right atrium.(3) Seven typical sections were defined on coronal imaging:sternoclavicular joint, ascending aorta, bifurcation of pulmonary artery, bifurcation of trachea, intermite bronchus, basal vein and thoracic aorta.Conclusion The developed method was able to localize lung segments on pulmonary perfusion SPECT imaging.
4.Primary visceral myopathy: report of a case.
Yu-hua ZHOU ; Ya-bin ZOU ; Miao LI ; Xun SUN
Chinese Journal of Pathology 2012;41(8):568-569
5.Primary small cell carcinoma of the breast: report of a case.
Li-mei QU ; Gang ZHAO ; Ya-bin ZOU ; Yu-E SONG ; Li-rong BI
Chinese Journal of Pathology 2011;40(2):120-121
Aged
;
Breast Neoplasms
;
metabolism
;
pathology
;
surgery
;
Cadherins
;
metabolism
;
Carcinoma, Merkel Cell
;
metabolism
;
pathology
;
Carcinoma, Small Cell
;
metabolism
;
pathology
;
surgery
;
Diagnosis, Differential
;
Female
;
Humans
;
Lymphoma
;
metabolism
;
pathology
;
Melanoma
;
metabolism
;
pathology
;
Phosphopyruvate Hydratase
;
metabolism
;
Synaptophysin
;
metabolism
7.Primary cardiac embryonal rhabdomyosarcoma: report of a case.
Liang GUO ; Zhen-yu WANG ; Ya-bin ZOU ; Li-rong BI
Chinese Journal of Pathology 2013;42(9):621-622
Calbindin 2
;
metabolism
;
Heart Neoplasms
;
metabolism
;
pathology
;
surgery
;
Humans
;
Male
;
Middle Aged
;
MyoD Protein
;
metabolism
;
Myogenin
;
metabolism
;
Rhabdomyosarcoma, Embryonal
;
metabolism
;
pathology
;
surgery
8.Numerical computation on the scaffolds models with regular square holes using nonlinear fluid-solid-coupling approaches
Ya-Bin ZHAI ; Yu-Hong CUI ; Wen-Jiao LI
Journal of Medical Biomechanics 2010;25(1):4-10
Objective The influencing parameters of solid and fluid computing fields for the scaffolds models with regular square holes were discussed by nonlinear fluid-solid-coupling approaches.The numerical computational resuits of which the models were regarded as both rigid body and non-linear elasticity were compared as well.Method One direct fluid-solid-coupling approach and two indirect fluid-solid-coupling approaches were adopted,and the calculating reliability of three kinds of fluid-solid coupling methods was verified.Rasults The solid-fluidcoupling computational results are obtained in light of 12 kinds of scaffolds models which are constructed by 3 groups of square side length(50,100 and 150 μm)and 4 groups of porosity(61%,65%,77%and 84%).The field parameters of those solid models including stress,strain and displacement and those fluid models including static pressure,velocity,wall shear stress and strain rate are achieved and compared.Conclusion There appear some difference between the results of porous scaffold models as a rigid body and as non-linear elasticity.The different porosity with the same pore radius or the different pore radius with the same porosity would affect the field parameters of solid models and fluid models in varying degrees.
9.Numerical computation on the scaffolds models with regular square holes using nonlinear fluid-solid-coupling approaches
Ya-Bin ZHAI ; Yu-Hong CUI ; Wen-Jiao LI
Journal of Medical Biomechanics 2010;25(1):4-10
Objective The influencing parameters of solid and fluid computing fields for the scaffolds models with regular square holes were discussed by nonlinear fluid-solid-coupling approaches.The numerical computational resuits of which the models were regarded as both rigid body and non-linear elasticity were compared as well.Method One direct fluid-solid-coupling approach and two indirect fluid-solid-coupling approaches were adopted,and the calculating reliability of three kinds of fluid-solid coupling methods was verified.Rasults The solid-fluidcoupling computational results are obtained in light of 12 kinds of scaffolds models which are constructed by 3 groups of square side length(50,100 and 150 μm)and 4 groups of porosity(61%,65%,77%and 84%).The field parameters of those solid models including stress,strain and displacement and those fluid models including static pressure,velocity,wall shear stress and strain rate are achieved and compared.Conclusion There appear some difference between the results of porous scaffold models as a rigid body and as non-linear elasticity.The different porosity with the same pore radius or the different pore radius with the same porosity would affect the field parameters of solid models and fluid models in varying degrees.
10.Micromovement characteristic of distal tibiofibular joints in normal Chinese.
Qing-Jun LIU ; Bin LIN ; Ya-Yu XU ; Zhi-Min GUO
China Journal of Orthopaedics and Traumatology 2012;25(8):627-631
OBJECTIVETo analyze micromovement of distal tihiofihular joints in different motion range of ankle joint ,and define the micromovement characteristic and range of distal tibiofihular joints.
METHODSTwelve normal Chinese were chosen. There were 9 males and 3 females, aged from 19 to 37 years old with an average (26.5 +/- 0.5) years. Detection terminals of laser photographic scanner were installed near the highest point between medial malleolus and lateral malleolos, the change of detection terminals on the position of dorsiflex, extension, introversion and eversion of ankle joint were scanned by 3D-laser scanner. The displacement of two detection terminals on the X ,Y and Z-axis (X-axis stands for the vertical-axis between coronal plane and Z-axis Y-axis stands for the vertical-axis between sagittal plane and Z-axis Z-axis stands for macroaxis of tibia).
RESULTSAlong with increased range of motion on the position of dorsiflex ,extension, introversion and eversion of ankle joint, the range of micromovement of distal tibiofibolar joints increased too. The max-displacement of X, Y and Z were respectively (1.04 +/- 0.12) mm, (1.70 +/- 0.16) mm and--(0.87 +/- 0.10) mm.
CONCLUSION3D-laser scanner can be used to determine the detailed displacement of distal tibiofibolar joint on the X , Y and Z, and measure the motion of distal tibiofibular joint. The method can be used to study the pathologic change of distal tibiofibular joint ,and provide basic biomechnics data for internal fixtor fitting for the characteristic of distal tibiofibular joint.
Adult ; Ankle Joint ; physiology ; Asian Continental Ancestry Group ; Female ; Fibula ; Humans ; Male ; Movement ; Range of Motion, Articular ; Tibia ; Young Adult