2.The Substrate Specificity of Cyclic Imide Hydrolase Mutants
Yun-Xia CHEN ; Li-Xi NIU ; Jing-Ming YUAN ; Ya-Wei SHI ;
China Biotechnology 2006;0(06):-
The effect of C-terminal region residues on the substrate specificity of a novel cyclic imide hydrolase (CIH), a recombinant cyclic imide hydrolase (CIH293), and its mutants deleted or substituted at C-terminus (CIH291, CIH290, KK292-293EE) was reported. The substrate specificity and kinetic parameters of the mutants were analyzed by both the spectrophotometric assay and high-performance liquid chromatography. Results show that the substrate specificity of mutants was not obviously changed, but slightly low for the affinity between the substrate and enzyme, compared with the wild-type enzyme, CIH293. In conclusion, the last three residues of CIH293 play an important role for the enzyme activity.
3.Tension-free hernia repair for incisional hernia of the abdominal wall
KELIMU ; Cheng ZHANG ; Wei-Ya NIU ; AIKEBAIR ; Azhati KAISAIER ; Wen-Qing YU ; Zi-Li WANG ; Yi-liang LI
Chinese Journal of General Surgery 2000;0(12):-
Objective To evaluate tension-free hernia Onlay repair with premuscular positioning of the prosthesis for the treatment of ineisional henia of the abdominal wall.Methods In this study 126 patients with incisional henia were treated with a tension-free manner of hernia repair by using synthetic material ONLAY between September 1999 and June 2007.Results All operations were successful.There was no hospital death or severe postoperative complications.The average age was 58.5 years old ranging from 28 to 89.There were 67 patients in which the abdominal defect ranged from 5~10 cm,and 59 patients with abdominal defect≥10 cm.The mean operating time was 95(70~120)min,and the average intraoperative blood loss was 80 ml(60~250 ml).The mean postoperative hospitalization was 14.5 days(10~28 d). Patients were followed-up from 3 to 96 months,and 3 patients suffered from hernia recurrence(2.38%). Conclusions The ONLAY repair of ineisional hernia of the abdominal wall with synthetic material mesh was a safe procedure,especially for those with large abdominal wall defects.
5.The effect of cold air and dust weather on the content of IL-6,8- iso-PGF2α and 11-DH-TXB2 in urine.
Ya-xiong WAN ; Bin LUO ; Yan-rong SHI ; Mei-chi CHEN ; Li-na WANG ; Ren-hong WANG ; Jing-ping NIU
Chinese Journal of Applied Physiology 2016;32(1):5-12
Cold Temperature
;
Dinoprost
;
analogs & derivatives
;
urine
;
Dust
;
Humans
;
Interleukin-6
;
urine
;
Thromboxane B2
;
analogs & derivatives
;
urine
;
Weather
6.Experimental Study of Adrenomedullin in Autoimmune Myocarditis Induced by Immunization of Mice with Lactobacillus Casei Cell Wall Element
ji-wei, ZHANG ; hong-wei, WANG ; mei-zhen, NIU ; hong, SHI ; qing-jun, LIU ; pei-xuan, CHENG ; ya -li, LIU
Journal of Applied Clinical Pediatrics 2004;0(11):-
Objective To study adrenomedullin (AM) mRNA and protein expression level in myocardium of autoimmune myocarditis animal models induced by immunization of mice with lactobacillus casei cell wall element(LCWE). Methods Forty-five Balb/c male mice were randomly divided into experimental group (n = 30) and control group (n = 15), which were intraperitoneally injected with LCWE and phosphate buffered solution(PBS) at day 0,3,5 and 10,respectively. Sera and myocardium samples were gained 14,21 and 28 days after the first immunization. AM expression levels were determined by semiquantitative reverse transcriptase-polymerase chain reaction(RT- PCR) and immunchistochemistry,and mycardial histopathological lesions were observed. The anti- myosin antibodies in different stages were examined by an ELISA. Results There were myocardial necrosis or inflammatory infiltration in the experimental group, but myocardial lesions were not found in the control group. Anti - myosin antibodies were detected in sera of experimental mice,but not in control group. Immunchistochemistry findings demonstrated that AM expression level was higher in the experimental group than in the control group( P
7.Pulmonary embolism excluded acute coronary syndrome by coronarography: a retrospective analysis.
Chun-Ping LIU ; Jun-Xia LI ; Li-Li NIU ; Hang-Wei CHEN ; Bo TAN ; Ya-Ping WANG
Chinese Medical Journal 2012;125(16):2867-2872
BACKGROUNDPulmonary embolism (PE) is often mistaken as acute coronary syndromes (ACS) because of the considerable overlap in their clinical features. We evaluated the factors causing misdiagnosis of PE as ACS and factors that differentiate PE from ACS to improve the diagnosis efficacy of PE.
METHODSThe medical records of 22 consecutive PE patients, between 2001 and 2010, who were initially suspected of ACS were retrieved. ACS was ruled out by coronary artery angiography before a definite diagnosis of PE was given. Twenty-two contemporary cases of ACS matched by age and sex were recruited as controls. Clinical manifestations, electrocardiograms (ECG), and biomarkers of these patients were reviewed retrospectively. The factors causing misdiagnosis of PE as ACS and factors differentiating PE from ACS were evaluated.
RESULTSWe found two leading causes of misdiagnosis of PE as ACS. One is that PE can resemble ACS in several clinical aspects (symptoms and signs, ECG findings, plasma cardiac troponin I, and D-dimer). The other is the insufficient recognition of PE by clinicians. Risk factors for venous thromboembolism (VTE), especially deep venous thrombosis (DVT), together with signs of PE, such as unexplained dyspnea or hypoxemia, and right ventricular pressure overload on ECGs are valuable in differentiating the two diseases.
CONCLUSIONSDifferentiation between PE and ACS is sometimes challenging. Adequate awareness of the risk factors for VTE and the signs of PE are crucial in the diagnosis of PE.
Acute Coronary Syndrome ; diagnostic imaging ; Adult ; Aged ; Coronary Angiography ; Electrocardiography ; Female ; Humans ; Male ; Middle Aged ; Pulmonary Embolism ; diagnostic imaging ; Retrospective Studies
8.Comparison of exosome extracting methods from human umbilical cord mesenchymal stem cells
Ying GUO ; Xiu-Wei WANG ; Yu-Hu NIU ; Li WANG ; Nan ZHOU ; Bai-Yi LI ; Zhen-Dong WANG ; Pin ZHANG ; Ya-Jie GAO ; Bo NIU
Chinese Journal of Tissue Engineering Research 2018;22(9):1382-1388
BACKGROUND: Cell-free stem cell therapy has been an issue of concern, but there is no conclusion on how to extract high-quality exosomes. OBJECTIVE: To extract exosomes from human umbilical cord mesenchymal stem cells by using three different methods, and then to screen the optimal method. METHODS: Exosomes were extracted from human umbilical cord mesenchymal stem cells by using the Total Exosome Isolation test kit, Exo Quick test kit and differential ultracentrifugation method, respectively. Then, transmission electron microscopy was used for morphological observations, BCA was utilized to quantify the protein, and western blot assay was applied to detect surface markers CD9, CD81 and CD63. RESULTS AND CONCLUSION: Extraction of exosomes was completed by all the three methods, and round or oval membranous vesicles were observed under the transmission electron microscope. The protein content and purity of exosomes was highest in the differential ultracentrifugation group, followed by the Exobiology Quick kit group, and lowest in the Total Exosome Isolation kit group, and there were significant differences among the three groups (P < 0.05). Under the same protein concentration, surface specific markers, CD81, CD63 and CD9, were expressed highest in the differential ultracentrifugation group, followed by the Exobiology Quick kit group, and lowest in the Total Exosome Isolation kit group. The operating time was significantly lower in the Exobiology Quick kit group compared with the other two groups (P < 0.05). To conclude, despite a longer operating time, the differential ultracentrifugation method is a rational method to extract enough exosomes with relative high purity.
9.Differences in expression of Notch1, E-cadherin, vascular endothelial growth factor A and C, and chemokine receptor 4 gene in breast suspension mammosphere cells and normal adherent cells.
Zhao-hui WANG ; Chuan-wei LI ; Ai-lian YU ; Guang-fu YU ; Ying-hui ZHAO ; Ya ZHANG ; Lu CAO ; Li-ting NIU ; Xue-chun WANG
Chinese Journal of Pathology 2013;42(5):338-339
10.Early repair of full layer eyelid defect caused by chemical burn.
Dao-gong LIU ; Xi-hua NIU ; Wei QIN ; Lin LI ; Hong-feng ZHAI ; Li-ya WANG
Chinese Journal of Burns 2003;19(6):349-350
OBJECTIVETo investigate the optimal time and method of the early repair of the full layer eyelid defect caused by chemical burn.
METHODSFree nasal septum mucosal cartilage flap with muscle flap, skin grafting, or skin flap were performed in 18 cases (19 eyelids) with chemical burn within 4 postburn weeks. Eyelid reconstruction and corneal transplantation were performed at the same time in 4 patients.
RESULTSAll the reconstructed eyelids and transplanted cornea survived. The incidence of severe complications, such as exposure keratitis, corneal ulcer and eyeball perforation decreased.
CONCLUSIONFull layer eyelid defect caused by chemical burn should receive early reconstruction and repair, including timely reconstruction of eyelid for the sake of protecting the eyesight and of alleviating the inflammatory reactions, and the corneal transplantation should be done at the same time to avoid corneal perforation. Nasal septum mucosal cartilage flap could be ideal for the eyelid reconstruction.
Adult ; Burns, Chemical ; surgery ; Corneal Transplantation ; Eyelids ; injuries ; surgery ; Female ; Humans ; Male ; Middle Aged